Prosthetic joint infection caused by Neisseria sicca/subflava
Hassaan Abid, Akrum Saleh, Michael DeBrota, Hamza Waheed, Rodney Yuhico, Ritika Zijoo

TL;DR
A rare case of prosthetic joint infection caused by Neisseria sicca/subflava is reported, highlighting the importance of considering uncommon bacteria in such infections.
Contribution
This case report adds to the limited literature on Neisseria sicca/subflava as a rare cause of prosthetic joint infection.
Findings
Neisseria sicca/subflava was identified as the causative agent in a prosthetic joint infection.
The patient showed clinical improvement after prosthesis explantation and targeted antibiotic therapy.
Abstract
Prosthetic joint infections are most commonly caused by staphylococci and streptococci, while commensal Neisseria species are exceedingly rare etiologic agents. We report a 71-year-old white male with multiple comorbidities who presented with progressive left knee pain 9 years after total knee arthroplasty. Synovial fluid analysis showed an elevated leukocyte count with neutrophil predominance, and cultures subsequently grew Neisseria sicca/subflava. Given the concern for prosthetic joint infection, he underwent prosthesis explantation and received intravenous ceftriaxone 2 g daily for 6 weeks. Poor dentition was identified as a suspected potential source of hematogenous seeding. The patient demonstrated clinical improvement with surgical intervention and targeted antimicrobial therapy. Neisseria sicca/subflava should be recognized as a rare but clinically significant cause of…
Genes, proteins, chemicals, diseases, species, mutations and cell lines named across the full text — each resolved to its canonical identifier and authoritative record.
Peer Reviews
No public reviews on file for this paper yet. If you reviewed it on a platform where reviews are public (OpenReview, ICLR, NeurIPS, ICML), you can paste yours below so the community can read it here.
Videos
No videos yet. Explain this paper in a talk, walkthrough, or lecture? Add one.
Taxonomy
TopicsInfective Endocarditis Diagnosis and Management · Orthopedic Infections and Treatments · Bacterial Infections and Vaccines
Introduction
Prosthetic joint infections (PJIs) occur in the tissues surrounding a joint prosthesis, such as hip, knee, or shoulder implants, and differ significantly from native joint infections owing to the ability of microorganisms to adhere to prosthetic material and form biofilms. According to a review in The New England Journal of Medicine, the most common organisms causing PJI are coagulase-negative staphylococci (37%), followed by Staphylococcus aureus (24%), Streptococcus species (14%), Enterococcus species (8%), Cutibacterium species (8%), and Enterobacterales (7%). Less common organisms include Corynebacterium species, Pseudomonas species, fungi, and mycobacteria [1].
Commensal Neisseria species are infrequently associated with musculoskeletal infections. Existing reports describe isolated cases of vertebral osteomyelitis, discitis, and endocarditis, but joint involvement remains exceedingly rare [2–6]. A recent literature review identified only a small number of osteomyelitis cases attributed to N. sicca, and current IDSA guidelines do not include it among pathogens implicated in septic arthritis [3, 4]. Given the scarcity of reported cases, further characterization of N. sicca pathogenicity is warranted.
Case description
A 71-year-old white male presented with worsening left knee pain. His past medical history was significant for morbid obesity, coronary artery disease, heart failure with reduced ejection fraction, paroxysmal atrial fibrillation, hypertension, and hyperlipidemia. Past surgical history included right total hip arthroplasty (2017), left total knee arthroplasty (2015), and placement of an implantable cardioverter-defibrillator.
He reported a sudden onset of localized, nonradiating pain while rising from a chair, progressively worsening over 2 months. He denied trauma, falls, fever, or chills. Examination revealed swelling, warmth, erythema, and mild pain with external rotation.
A knee aspiration drained 20 cc of straw-colored, blood-tinged fluid. The initial assessment favored arthritis, and he received acetaminophen while awaiting results. The results for the synovial fluid analysis are presented in Table 1. Table 1. Synovial Fluid AnalysisTestResultColorRedClarityTurbidTotal nucleated cells7237/µLWhite blood cell (WBC) count7220/µLRed blood cell (RBC) count21,000/µLPolymorphonuclear neutrophils (PMNs)80%CrystalsNoneGram stainMany WBCs; no organismsFinal cultureNeisseria sicca/subflavaSusceptibilityNot performed
Additional inflammatory markers showed ESR 98 mm/hr and CRP 4.2 mg/dL.
The diagnostic evaluation was guided by the 2018 Musculoskeletal Infection Society (MSIS)/International Consensus Meeting (ICM) criteria for prosthetic joint infection, which integrate clinical findings, inflammatory markers, synovial fluid analysis, and microbiologic data. Although the synovial leukocyte count did not meet major MSIS/ICM criteria for acute prosthetic joint infection, chronic and low-grade PJIs, particularly those caused by low-virulence organisms, may present with lower synovial leukocyte counts and attenuated inflammatory responses, especially in late-onset infections occurring years after implantation. When interpreted alongside markedly elevated inflammatory markers, progressive clinical symptoms, and a positive synovial fluid culture, the overall clinical picture was felt to be most consistent with a probable chronic prosthetic joint infection rather than a noninfectious arthropathy.
Synovial fluid cultures were obtained via sterile joint aspiration at an outside facility before transfer. Detailed information regarding specific culture media (aerobic, anaerobic, or enrichment) and incubation conditions was not available. No antibiotics were administered prior to joint aspiration. The organism was reported as Neisseria sicca/subflava using routine clinical laboratory identification methods at the referring institution. Blood cultures obtained before antibiotic initiation at our institution remained negative. Repeat intraoperative cultures obtained at the time of prosthesis explantation were also negative.
Given the positive synovial culture and clinical concern for prosthetic joint infection, the patient was transferred for urgent prosthesis explantation and initiated on intravenous ceftriaxone 2 g daily. The infectious diseases team noted poor dentition as a suspected potential source of hematogenous seeding, given the organism’s known oropharyngeal colonization. He recovered uneventfully with plans for 6 weeks of intravenous antimicrobial therapy.
At the time of manuscript submission, the patient continued treatment with ongoing symptomatic and functional improvement.
Discussion
This case highlights an exceptionally rare cause of prosthetic joint infection. While most PJIs involve staphylococci, streptococci, or enteric Gram-negative bacilli, Neisseria sicca/subflava has not been well described as a causative pathogen in prosthetic joint infection. A focused literature search was conducted using PubMed and Google Scholar with combinations of the terms “Neisseria sicca,” “Neisseria subflava,” “prosthetic joint infection,” and “periprosthetic joint infection.” While prior reports describe invasive infections such as osteomyelitis, discitis, and endocarditis caused by N. sicca, no published cases of prosthetic joint infection attributable to Neisseria sicca/subflava were identified in the available English-language literature [3–7].
Commensal Neisseria species are often dismissed as contaminants; however, several features supported the interpretation of this isolate as a true pathogen rather than contamination. These included sterile sampling technique, absence of prior antibiotic exposure, elevated inflammatory markers, progressive clinical symptoms, and subsequent clinical improvement following prosthesis explantation and targeted antimicrobial therapy.
The presence of a positive preoperative synovial fluid culture with negative intraoperative explant cultures introduces diagnostic complexity. Potential explanations include low bacterial burden, fastidious organism growth characteristics, and sampling variability. Discordant culture results are well described in chronic, low-grade prosthetic joint infections and do not exclude infection when clinical, laboratory, and microbiologic features collectively support the diagnosis.
Treatment strategies for such rare pathogens are not well defined, as existing guidelines do not address commensal Neisseria species [8, 9]. However, most Neisseria species are susceptible to third-generation cephalosporins, supporting our approach of 6 weeks of ceftriaxone following prosthesis removal.
Our case report fills several important gaps in medical literature:
- Pathogenic expansion: it demonstrates that N. sicca/subflava, typically regarded as a benign oral commensal, can cause late-onset PJI.
- Therapeutic uncertainty: it underscores the absence of susceptibility data or guideline-based therapy for this organism.
- Microbiome consideration: it emphasizes the need to evaluate oral health as a potential source of atypical PJIs.
Conclusion
This case demonstrates that even low-virulence commensal organisms such as Neisseria sicca/subflava can cause prosthetic joint infection. It underscores the importance of applying established diagnostic frameworks, such as MSIS/ICM criteria, while incorporating clinical judgment in atypical presentations. Consideration of uncommon pathogens is particularly important in late-onset prosthetic joint infections, especially in patients with potential risk factors such as poor oral health.
The reference list from the paper itself. Each links out to its DOI / PubMed record.
- 1Tamma PD, et al. IDSA guidance on resistant gram-negative infections. Clin Infect Dis. 2023.10.1093/cid/ciad 42837463564 · doi ↗ · pubmed ↗
- 2Heiddal S, et al. Neisseria sicca native-valve endocarditis. Clin Infect Dis. 1993.10.1093/clind/16.5.6678507758 · doi ↗ · pubmed ↗
- 3Browning S, et al. Neisseria meningitidis PJ Is. J Bone Jt Infect. 2020.10.5194/jbji-6-33-2020 PMC 751764732983846 · doi ↗ · pubmed ↗