Results on Proton-Irradiated 3D Pixel Sensors Interconnected to RD53A Readout ASIC
Jordi Duarte-Campderros (on behalf on the CMS Collaboration) and, Esteban Curras, Marcos Fernandez, Gervasio Gomez, Andrea Garcia and, Javier Gonzalez, Esther Silva, Ivan Vila, Richard Jaramillo and, Marco Meschini, Rudy Ceccarelli, Mauro Dinardo, Simone Gennai and, Luigi Moroni

TL;DR
This study demonstrates that 3D pixel sensors bump-bonded to RD53A ASIC maintain high hit detection efficiency after proton irradiation up to $1\times10^{16}$ n$_{eq}$/cm$^2$, confirming their suitability for high-radiation environments like HL-LHC.
Contribution
First irradiation test of fine pitch 3D pixel sensors bump-bonded to RD53A ASIC showing no efficiency degradation at high fluence.
Findings
Sensors retain efficiency after irradiation
3D sensors are highly radiation tolerant
Suitable for HL-LHC inner detector layers
Abstract
Test beam results obtained with 3D pixel sensors bump-bonded to the RD53A prototype readout ASIC are reported. Sensors from FBK (Italy) and IMB-CNM (Spain) have been tested before and after proton-irradiation to an equivalent fluence of about cm (1 MeV equivalent neutrons). This is the first time that one single collecting electrode fine pitch 3D sensors are irradiated up to such fluence bump-bonded to a fine pitch ASIC. The preliminary analysis of the collected data shows no degradation on the hit detection efficiencies of the tested sensors after high energy proton irradiation, demonstrating the excellent radiation tolerance of the 3D pixel sensors. Thus, they will be excellent candidates for the extreme radiation environment at the innermost layers of the HL-LHC experiments.
| 3D Pixel-RD53A Linear FE | ||
|---|---|---|
| Before irradiation | ||
| After irradiation |
Peer Reviews
No public reviews on file for this paper yet. If you reviewed it on a platform where reviews are public (OpenReview, ICLR, NeurIPS, ICML), you can paste yours below so the community can read it here.
Videos
No videos yet. Explain this paper in a talk, walkthrough, or lecture? Add one.
Results on Proton-Irradiated 3D Pixel Sensors Interconnected to RD53A Readout ASIC
J. Duarte-Campderros
Instituto de Fisica de Cantabria (Universidad de Cantabria/CSIC), Av. de los Castros s/n 39005 Santander, Spain
European Organization for Nuclear Research (CERN), 1211 Geneva 23, Switzerland
on behalf of the CMS Collaboration
E. Currás
M. Fernández
G. Gómez
A. García
J. González
E. Silva
I. Vila
R. Jaramillo
M. Meschini
R. Ceccarelli
M. Dinardo
S. Gennai
L. Moroni
D. Zuolo
L. Demaria
E. Monteil
L. Gaioni
A. Messineo
G. F. Dalla Betta
R. Mendicino
M. Boscardin
S. Hidalgo
A. Merlos
G. Pellegrini
D. Quirion
M. Manna
INFN Sezione de Firenze, Via Giovanni Sansone, 1, 50019 Sesto Fiorentino FI, Italy
INFN Sezione di Milano-Bicocca, Milano, Italy
University of Milano Bicocca, Milano, Italy
INFN Sezione di Torino, Via Pietro Giuria, 1, 10125 Torino, Italy
INFN Sezione di Pavia, Via Agostino Bassi, 6, 27100 Pavia, Italy
Universita degli studi di Bergamo, Bergamo, Italy
INFN Sezione di Pisa and Universita di Pisa, Largo Bruno Fibonacci, 2, 56127, Pisa, Italy
Università degli Studi di Trento, Via Calepina, 14, 38122 Trento, Italy
INFN Sezione di Padova, Gruppo Collegato di Trento, Trento, Italy
FBK-Fondazione Bruno Kessler, Via Sommarive, 18 - Povo 38123 Trento, Italy
Centro Nacional de Microelectrónica, IMB-CNM (CSIC), 08193 Barcelona, Spain
Abstract
Test beam results obtained with 3D pixel sensors bump-bonded to the RD53A prototype readout ASIC are reported. Sensors from FBK (Italy) and IMB-CNM (Spain) have been tested before and after proton-irradiation to an equivalent fluence of about ( equivalent neutrons). This is the first time that one single collecting electrode fine pitch 3D sensors are irradiated up to such fluence bump-bonded to a fine pitch ASIC. The preliminary analysis of the collected data shows no degradation on the hit detection efficiencies of the tested sensors after high energy proton irradiation, demonstrating the excellent radiation tolerance of the 3D pixel sensors. Thus, they will be excellent candidates for the extreme radiation environment at the innermost layers of the HL-LHC experiments.
keywords:
Performance of High Energy Physics Detectors, Pixelated detectors and associated VLSI electronics, Radiation-hard electronics, Radiation damage to detector materials (solid state), Radiation-hard detectors
††journal: NIM-A
1 Radiation Hardness and 3D Columnar Pixel Sensors
Pixel detectors in the innermost layers of the High Luminosity Large Hadron Collider (HL-LHC) experiments will have to survive a fluence in excess of ( equivalent neutrons), while preserving high tracking efficiency [1]. It has already been demonstrated [2] that 3D pixel sensors are sufficiently radiation tolerant to resist the expected fluence on the innermost layers of the tracking systems of HL-LHC experiments, although it was done by using a coarse pitch readout chip. This work, complementing ref. [3], uses for the first time 3D sensors bump-bonded to a fine pitch readout ASIC (RD53A). In addition, the study presents characterization results of 3D pixel sensors of pitch with one single collecting electrode per cell, irradiated up to .
Columnar 3D pixel sensors [4, 5] possess several intrinsic properties making them good candidates to create the layers of a tracking system exposed to an extreme radiation environment. For example, the voltage needed to fully deplete the sensor is much lower than in an equivalent planar sensor, particularly after irradiation, due to small distance between junction and ohmic contacts. For the same reason, charge carriers travel less distance than in an equivalent planar detector, therefore they are less impacted by trapping. Charge carriers in the 3D pixel sensors travel only for a pixel pitch independently of the sensor thickness, which is the driving parameter for planar pixels. The 3D pixels have also a very fast response time. Figure 1 compares both planar and 3D designs.
The 3D sensors used in this work were fabricated at the FBK in Trento (Italy), and in the IMB-CNM in Barcelona (Spain). Sensors from FBK were bump-bonded to the RD53A [6] readout-chip, while sensors from IMB-CNM were bump-bonded to the ROC4SENS [7] chip. The substrates were p-type Si-Si high-resistivity wafers with thickness in the case of the FBK sensors, and conventional p-type high-resistivity FZ wafers of thickness, for the IMB-CNM sensors. Detector and fabrication description can be found on ref. [4, 5]. Figure 2 shows both single-sided FBK and double-sided IMB-CNM pixel layout sensors.
The sensors were created with two different pixel cells: and , the latter having one (1E) or two (2E) collecting electrodes per cell. The 1E case is particularly interesting given the large yield when producing them. Two examples of pixel cells are shown in figure 3. Both cell sizes are presently under evaluation in the Compact Muon Solenoid (CMS) collaboration for the inner layers of the pixel detectors for HL-LHC.
After fabrication, the FBK pixel sensor wafers were processed for UBM (Under Bump Metallization), thinned down to total thickness, diced and bump-bonded to RD53A prototype chips at IZM (Berlin, Germany). The RD53A chip has 76800 readout channels (400 rows and 192 columns with a bump pad pitch of ) and measures . The pixel sensor bonded to the readout chip needs to be glued and wire-bonded onto an adapter card in order to be tested; these units will be referred to as modules in the following text. All results referring to the FBK+RD53A modules were obtained with the Linear Front-End [fe] (FE) in the central zone of RD53A (136 columns wide, from 128 to 263).
IMB-CNM sensors were also processed for UBM and then bump-bonded to ROC4SENS readout chips. The ROC4SENS is a generic chip able to readout without zero suppression, and therefore specially well suited for sensor studies. The chip has a bump pad pitch of with 160 rows and 155 columns providing 24800 pixels in a surface.
2 Irradiation and Test Beam setup
Irradiations were performed in 2017 for the IMB-CNM sensors, and in 2018 for the FBK sensors at the CERN IRRAD facility [8], a high intensity proton beam which has a FWHM of in x and y directions. The target fluence for the IMB-CNM sensors was , and for the FBK ones. The latter modules were tilted on the IRRAD beam at an angle of in order to homogeneously irradiate the sensors and readout chip areas. The corresponding total ionizing dose was for .
Visual inspections after irradiation and data analysis are showing that the FBK modules were displaced with respect to the irradiation beam axis by a few millimeters and therefore the nominal fluence was reached only in a part of the modules, in particular in about half of the linear FE. Several measurements and cross-checks are being performed in order to establish the effective fluence integrated on the modules. All results shown here are based on the nominal requested equivalent fluence. Figure 4 shows several modules mounted on the supports ready to be irradiated and one of the modules characterized in this work.
RD53A modules were tested in two test beam experiments at the CERN North Area H6B before and after irradiation in July and October 2018 respectively. The test beam facility at CERN provided for this study hadrons, allowing to characterize the sensor response to minimum ionizing particles. Particle trajectories are measured by the high-spatial-resolution planes of an EUDET-type telescope [9] with less than accuracy, and spatially correlated with the hits measured at our modules, i.e. Devices Under Test (DUT). An extra plane is placed between the telescope planes and is used to correlate in time the telescope with the DUT hits. The hit efficiency of a DUT is calculated from the available trajectories with a hit in the reference sensor, and looking for a hit in the DUT. More details on an equivalent test beam setup and data analysis can be found at ref. [10].
Irradiated modules were kept cold at temperatures between and using dry ice bricks. The temperature was monitored via PT1000 sensors located close to the backside of the module and via NTC resistors soldered on the adapter card. Both sensors gave consistent measurements.
The readout chip parameters were tuned in order to reach low thresholds and noise, having at most 1.5% masked pixels because of noisy channels. For the irradiated modules the average signal threshold was set to about 1400 electrons, with a noise value of 105 electrons for non-masked pixels, as shown in figure 5 for a . Similar parameters were found for the .
The color scale for the threshold distribution represents the 4-bit DAC value used for the trimming of each individual pixel response.
3 Sensor response and Results
The 3D modules prior to irradiation reached hit detection efficiencies above for perpendicular incident tracks, already at moderate bias (less than ).
After irradiation, a bias voltage of at least was needed to reach similar efficiency. Figure 6 shows the comparison of hit efficiency before and after irradiation for , and figure 7 for pixel size modules, and perpendicular incident tracks. In the efficiency plots the hits reconstructed over the whole module are projected on a pixel cell window to put in evidence the sensor geometry and the possible effects of the columnar electrodes.
The geometrical inefficiency due to the columnar electrode diameter of was estimated to be around .
This effect can be greatly reduced by tilting the module on the beam. Hit efficiency higher than was recovered when sensors are tilted with respect to the incident particles in order to maximize the charge sharing between pixels, as shown in figure 8. This proves that the tested 3D sensors, both and are radiation tolerant up to the extreme expected doses at the HL-LHC. In particular, in the case of the , 1 electrode is enough to reach high hit efficiency. ROC4SENS modules were tested at the DESY test beam facility [11] with electrons. As expected no significant reduction of the sensor hit efficiency was observed after irradiation and overall efficiency of at normal incidence was reached.
The hit detection efficiencies as calculated in our data analysis for different runs are reported in table 1.
The hit efficiency as a function of the applied bias voltage is reported in figure 9, where it can be observed that starting from the sensors reach the full depletion regime.
4 Conclusions and Outlook
Initial test beam results obtained with 3D pixel sensors show no significant degradation after proton irradiation up to at bias voltages below , confirming 3D pixel sensors as a possible robust option for the inner layers of future tracking detectors. In particular, it is shown that one single collecting electrode per cell is enough to assure high efficiency. New data is currently being analyzed from the CERN 2018 test beam campaign as well as from Fermilab and DESY test beams, in order to confirm and extend this study. At the beginning of 2019, a new 3D sensor batch was in production at FBK and a new batch with and pitch sensors just finished at IMB-CNM. These will be tested and characterized throughout 2019.
Acknowledgments
I wish to thank Nuria Castello-Mor for providing me the elegant template I used for the poster. We thank the RD53 Collaboration for the RD53A chip; we remind our results are not on chip performance but on sensor performance. The RD50 Collaboration for its support. Bonn ATLAS group for SCC cards and support for flip-chipping. Some of the measurements leading to these results have been performed at the CERN North Area Test Beam Facility at Prévessin (France). Some of the measurements leading to these results have been performed at the Test Beam Facility at DESY Hamburg (Germany), a member of the Helmholtz Association (HGF). This project has been partially supported by the Spanish Ministry of Science under grants FPA2015-71292-C2-2-P, FPA2017-85155-C4-1-R and FPA2017-85155-C4-2-R; and the European Union’s Horizon 2020 Research and Innovation programme under Grant Agreement no. 654168 (AIDA-2020).
The reference list from the paper itself. Each links out to its DOI / PubMed record.
- 1[1] CMS Collaboration, The Phase-2 Upgrade of the CMS Tracker , Tech. Rep. CERN-LHCC-2017-009. CMS-TDR-014, CERN, Geneva (Jun 2017). URL https://cds.cern.ch/record/2272264
- 2[2] J. Lange, G. Giannini, S. Grinstein, M. Manna, G. Pellegrini, D. Quirion, S. Terzo, D. Vázquez Furelos, Radiation hardness of small-pitch 3D pixel sensors up to a fluence of 3 × 10 16 3 superscript 10 16 3\times 10^{16} n eq /cm 2 , JINST 13 (09) (2018) P 09009. ar Xiv:1805.10208 , doi:10.1088/1748-0221/13/09/P 09009 . · doi ↗
- 3[3] M. Meschini, et al., First Results on 3D Pixel Sensors Interconnected to the RD 53A Readout Chip after Irradiation to 1 × 1\times 10 16 superscript 10 16 10^{16} neq cm -2 , in: 9th International Workshop on Semiconductor Pixel Detectors for Particles and Imaging (PIXEL 2018) Taipei, Taiwan, December 10-14, 2018, 2019. ar Xiv:1903.01963 .
- 4[4] G.-F. Dalla Betta, R. Mendicino, D. Sultan, M. Boscardin, G. Giacomini, S. Ronchin, N. Zorzi, G. Darbo, M. Meschini, A. Messineo, Small pitch 3D devices, Po S Vertex 2016 (2017) 028. doi:10.22323/1.287.0028 . · doi ↗
- 5[5] G. Pellegrini, J. P. Balbuena, D. Bassignana, E. Cabruja, C. Fleta, C. Guardiola, M. Lozano, D. Quirion, M. Ullan, 3D double sided detector fabrication at IMB-CNM, Nucl. Instrum. Meth. A 699 (2013) 27–30. doi:10.1016/j.nima.2012.05.087 . · doi ↗
- 6[6] M. Garcia-Sciveres, The RD 53A Integrated Circuit , Tech. Rep. CERN-RD 53-PUB-17-001, CERN, Geneva (Oct 2017). URL https://cds.cern.ch/record/2287593
- 7[7] R. Horisberger, H.-C. Kaestli, B. Meier, R. Tilman, S. Wiederkehr, ROC 4SENS – a generic readout chip for sensor studies, https://indico.cern.ch/event/663851/contributions/2788211 , Accessed: 2019-03-01.
- 8[8] PS-IRRAD Proton Facility, https://ps-irrad.web.cern.ch , accessed: 2019-02-12.
