Coherent electrical readout of defect spins in 4H-SiC by photo-ionization at ambient conditions
Matthias Niethammer, Matthias Widmann, Torsten Rendler, Naoya Morioka,, Yu-Chen Chen, Rainer St\"ohr, Jawad Ul Hassan, Shinobu Onoda, Takeshi, Ohshima, Sang-Yun Lee, Amlan Mukherjee, Junichi Isoya, Nguyen Tien Son,, J\"org Wrachtrup

TL;DR
This paper demonstrates a novel photo-electrical method for detecting and controlling defect spins in 4H-SiC at room temperature, offering a scalable and efficient alternative to fluorescence-based readout in quantum technology.
Contribution
It introduces a new electrical readout technique for defect spins in 4H-SiC that operates at ambient conditions, enhancing scalability and practicality for quantum devices.
Findings
Electrical detection of silicon vacancy spins achieved
Coherent spin control demonstrated at room temperature
Potential for scalable quantum device integration
Abstract
Quantum technology relies on proper hardware, enabling coherent quantum state control as well as efficient quantum state readout. In this regard, wide-bandgap semiconductors are an emerging material platform with scalable wafer fabrication methods, hosting several promising spin-active point defects. Conventional readout protocols for such defect spins rely on fluorescence detection and are limited by a low photon collection efficiency. Here, we demonstrate a photo-electrical detection technique for electron spins of silicon vacancy ensembles in the 4H polytype of silicon carbide (SiC). Further, we show coherent spin state control, proving that this electrical readout technique enables detection of coherent spin motion. Our readout works at ambient conditions, while other electrical readout approaches are often limited to low temperatures or high magnetic fields. Considering the…
Peer Reviews
No public reviews on file for this paper yet. If you reviewed it on a platform where reviews are public (OpenReview, ICLR, NeurIPS, ICML), you can paste yours below so the community can read it here.
Videos
No videos yet. Explain this paper in a talk, walkthrough, or lecture? Add one.
\alsoaffiliation
Max Planck Institute for Solid State Research, 70569 Stuttgart, Germany
Coherent electrical readout of defect spins in 4H-SiC by photo-ionization at ambient conditions
Matthias Niethammer
Matthias Widmann
Torsten Rendler
Naoya Morioka
Yu-Chen Chen
Rainer Stöhr
3rd Institute of Physics and Center for Applied Quantum Technologies, University of Stuttgart, 70569 Stuttgart, Germany
Jawad Ul Hassan
Department of Physic, Chemistry and Biology, Linköping University, SE-581 83 Linköping, Sweden
Shinobu Onoda
Takeshi Ohshima
National Institutes for Quantum and Radiological Science and Technology, Takasaki 370-1292, Japan
Sang-Yun Lee
Center for Quantum Information, Korea Institute of Science and Technology, Seoul 02792, Republic of Korea
Amlan Mukherjee
3rd Institute of Physics and Center for Applied Quantum Technologies, University of Stuttgart, 70569 Stuttgart, Germany
Junichi Isoya
Faculty of Pure and Applied Sciences, University of Tsukuba, Tsukuba 305-8573, Japan
Nguyen Tien Son
Department of Physic, Chemistry and Biology, Linköping University, SE-581 83 Linköping, Sweden
Jörg Wrachtrup
3rd Institute of Physics and Center for Applied Quantum Technologies, University of Stuttgart, 70569 Stuttgart, Germany
Abstract
Quantum technology relies on proper hardware, enabling coherent quantum state control as well as efficient quantum state readout. In this regard, wide-bandgap semiconductors are an emerging material platform with scalable wafer fabrication methods, hosting several promising spin-active point defects. Conventional readout protocols for such defect spins rely on fluorescence detection and are limited by a low photon collection efficiency. Here, we demonstrate a photo-electrical detection technique for electron spins of silicon vacancy ensembles in the 4H polytype of silicon carbide (SiC). Further, we show coherent spin state control, proving that this electrical readout technique enables detection of coherent spin motion. Our readout works at ambient conditions, while other electrical readout approaches are often limited to low temperatures or high magnetic fields. Considering the excellent maturity of SiC electronics with the outstanding coherence properties of SiC defects the approach presented here holds promises for scalability of future SiC quantum devices.
1 Keywords
silicon vacancy center, silicon carbide, PDMR, ODMR, electrical readout, coherent control
2 Main text
Solid state color centers have developed into a leading contender in quantum technology owing to their vast potential as hardware for quantum sensing and quantum networks 1, 2, 3, 4, 5, 6. Typically, these techniques employ optical control for spin state initialization and readout. Spins in solids can provide long spin relaxation and dephasing times and therefore constitute excellent quantum bits. In certain cases, \latine.g. for spins in wide-bandgap semiconductors, single spin manipulation and optical spin state readout is feasible 7, 8, 9, 10. A number of systems, like spin dopants in silicon 11, 12, 13 or quantum dots 14, 15, allow for electrical spin readout. However, because their spin polarization typically relies on Boltzmann statistics, they require low temperature operation or large magnetic fields 16.
In contrast, color centers in wide-bandgap semiconductors show efficient optical spin polarization at room temperature 17, 18. Electrical readout of color center spins at ambient conditions relies on an efficient mechanism for spin-to-current conversion. This can be realized by measuring a laser induced spin-dependent photocurrent, which is often referred to as photocurrent detected magnetic resonance (PDMR). Several publications have successfully demonstrated this principle for various materials 19, 20, 21, 22. Recently, this technique has been applied to the nitrogen-vacancy (NV) center in diamond, by combining electrical readout with optical excitation 23, 24 and even achieved single defect 25 detection. It turns out that the signal-to-noise ratio (SNR) in this approach is competitive to optical detection 25 and at the same time allows better integration into electronic periphery. However, diamond as host material is not compatible with industrial technologies, \latine.g. large-scale wafers and the development of efficient diamond electronics is still subject to research. Silicon carbide (SiC) on the other hand has attracted attention due to its outstanding optical, electrical and mechanical properties 3.
Traditionally, interest in defects in SiC was driven by their impeding properties to high power electronic devices 26. This has initialized a wealth of studies utilizing electron paramagnetic resonance 27, 28 and electrically detected magnetic resonance 29, 30, 31, 32, 33. Among many investigated phenomena, spin dependent recombination has been shown to allow for self-calibrating magnetometers in a non-coherent fashion 34. In addition, several spin-active defects with long spin coherence times 35, 10 even at room temperature 9, 36 have been found. The quantum properties of such color centers have lately been used to demonstrate magnetic field and temperature sensing 37, 38, 39, 40. In this work, we demonstrate electrical readout of a negatively charged silicon-vacancy (V) spin ensemble in a 4H-SiC device via PDMR at ambient conditions.
The negatively charged silicon vacancy V at the cubic lattice site (V) in 4H-SiC provides both, stable deep level energy states in a wide-bandgap host and a spin dependent intersystem crossing (ISC). Previous studies revealed, that the defect has a spin quartet manifold of S=3/2 41, 28 in ground state (GS) and excited state (ES), which are separated by () 42. GS and ES Landé g-factors are identical (g=2.003) and their respective zero field splittings (ZFS) are and \approx$$410\text{\,}\mathrm{MHz} 43 at ambient conditions. In addition, a long-lived metastable state gives rise to non-radiative and spin-dependent ISC relaxation, enabling optical spin state initialization and readout under ambient conditions 42, 44, 9. Furthermore, it provides excellent coherence times even at room-temperature 9, 36, 45.
In the following, we discuss the principle of PDMR and how it can be applied to V. Figs. 1(a)-(c) depict the underlying charge dynamics: a deep level defect absorbs a photon and is promoted from its GS to the ES. From there: (i) The system can decay back to the GS by emitting a photon. (ii) The system can undergo a non-radiative ISC \latinvia a metastable state (MS). A spin-state dependency of this ISC rate is usually exploited in optically detected magnetic resonance (ODMR). (iii) While being in the ES, the system can undergo a second optical excitation to the conduction band (CB). In case (iii), an excess electron populates the CB, and the defect charge state is changed to . To reach a steady-state charge distribution, the defect can re-capture an electron either from the CB, or from other recharging sources, \latine.g. from other defects in the surrounding, or from the valance band (VB) through photo-induced electron-hole pair generation. In the third case, the free electron in the CB and the hole in the VB can be measured as photocurrent.
If the ISC rates are spin-dependent, this charge circulation enables photo-electrical spin-state readout. Note that the second photon may also be absorbed by the MS during an ISC cycle. Because the overall lifetime in the ES and MS is determined by the ISC as well, the spin dependency of the ISC rate alters the chance for the second photon absorption. The amount of spin-dependent contribution to photocurrent by this process is then expected to be the sum of currents created by promoting an electron either from the ES or MS to the CB.
We assume the V to be initialized in the 1/2 spin subspace of the GS by optical illumination. During optical excitation, the ES is populated. If the ISC rate from ES to MS states is higher for 1/2 than for the 3/2 states, the chance for two-photon absorption from the ES of 3/2 states is higher.
Populating the 3/2 states by resonantly driving the spin transition will consequently increase the photocurrent. For an ionization from the MS to CB, a decrease in current should be measured. The overall sign and magnitude of the effect will thus be determined by the difference in absorption cross section, ISC rates, lifetime and population of the ES and MS.
The microstructure used in this work is a n*++/n-/n++* metal-semiconductor-metal (MSM) junction, which is shown in Fig. 2(a). Starting from a n-type 4H-SiC substrate, epitaxial growth was used to fabricate a three-layer stack: (i) a -thick vanadium-doped semi-insulating layer to reduce leakage currents into the substrate, (ii) a -thick n*-* layer with N-doping concentration of , and (iii) a -thick n*++* layer with N-doping concentration of . A nickel (Ni) layer of thickness was deposited forming a Schottky contact on the n*++* layer. The sample was etched down by , leaving fingers of various width as devices. Subsequently, the Ni and n*++* films were removed in rectangular center areas of various sizes, for optical access to the n*-* region (see zoomed inset in Fig. 2(a)). In this layer, we expect the charge state of the V to be stable. Additionally, gold is deposited on the contact pads for wire bonding (see Supporting Information).
After recording – curves of the device, we create a V ensemble by electron irradiation at with a dose of . This process degrades the contact quality and device conductivity due to carrier compensation 46 (see Supporting Information). However, this also results in minimizing the dark current, enabling us to maximize the amplifier gain, which is beneficial for electrical readout. We chose to perform measurements on a device with active area.
Optical excitation is performed with a laser (Toptica, iBeam smart), which is focused onto the SiC device using an NA=0.65 objective (Zeiss, Plan-Achromat 40). The sample is mounted on a 3D piezo stage with travel range (Physik Instrumente, P-561.3CD). A 3D Helmholtz coil arrangement is used for applying magnetic fields in arbitrary directions. Radiofrequency (RF) for spin control and manipulation are provided by a rubidium-referenced (EFRATOM, LPRO-101) signal generator (Rohde & Schwarz, SMIQ03B), pulsed by a microwave switch (Mini Circuits, ZASWA-2-50D), amplified (Mini Circuits, ZHL4240W) and finally applied via a coplanar waveguide on the printed circuit-board sample holder below the sample. This sample holder also incorporates contact pads, to which the device contacts are wire-bonded. For better SNR, we use a lock-in detection scheme (Stanford Research, SR830). Therefore the signal is locked to the laser pulses for photocurrent measurements and on the modulated RF pulses for ODMR, PDMR and Rabi measurements). As the RF pulses are short (), the locking is achieved by repeating the whole spin control pulse sequences with and without RF multiple times at a lock-in frequency of , as depicted in Fig. 1(d). Typical pulse lengths for optical initialization in PDMR are laser pulse followed by settling time.
To measure a spin-dependent photocurrent, a bias voltage is applied using a source measure unit (Keithley, 2636B). The resulting photocurrent is converted to a voltage by a transimpedance amplifier (Femto, DLPCA-200, gain of for PDMR, for Rabi), which is low-pass filtered at . By scanning the sample position, we record photocurrent maps. At each position, we measure the photocurrent as a function of excitation power and fit the recorded data with a second order polynomial function to infer the contributions of single- (linear) and two-photon (quadratic) processes. For ODMR measurements, we detect fluorescence emission from to using a photodiode (Newport, Model 2151) and feed the signal directly into the lock-in amplifier. All measurements are performed at a laser power of (unless stated otherwise) in order to keep the same experimental conditions for PDMR and ODMR. The beam in front of the photodiode is attenuated by an iris to prevent detector saturation. For PDMR measurements, the output of the transimpedance amplifier is connected to the lock-in amplifier instead of the photodiode. To avoid artefacts due to frequency-dependent coupling into the SiC device, we keep the RF frequency constant and stepwise change the magnetic field revealing the magnetic resonance induced signals. The magnetic field is roughly aligned along the -axis of the sample. In order to map the PDMR signal, we repeatedly measure and average the PDMR amplitude. This is done by subtracting the off-resonant signal from the on-resonance data. The off-resonant signal is obtained at a -field strength corresponding to detuning.
A similar approach is used for spin Rabi oscillation measurements. Here, a fixed field is applied and a RF field ( field) at the spin resonance frequency drives the system, while the RF pulse length is altered and the overall sequence duration is kept constant. To account for potential RF pick-up by the lock-in scheme, we subtract an off-resonant baseline signal as described for the PDMR mapping.
Fig. 2(b) shows the photocurrent map of our device. We find that the response is localized inside the center of the device. The spatial map of the contribution of two-photon process in the photocurrent extracted from quadratic fitting of the laser power dependency of photocurrent data (see Fig. 2(c)) is shown in Fig. 2(d). Comparing Fig. 2(b) with Fig. 2(d), we find that most areas show mainly linear response, indicating single photon absorption from shallow traps. In the center of the device, we observe a pronounced quadratic dependence. We perform all further measurements in this area.
We subsequently perform stepwise -field dependent measurements at fixed RF frequencies of and to resolve the resonances of 1/2 3/2 and 1/2 3/2 transitions, respectively. Both PDMR and ODMR results are shown in Fig. 3(a), exhibiting the expected magnetic resonance for both ODMR and PDMR except for a small difference in the resonance positions.
We tend to attribute the shift between ODMR and PDMR resonance to offset fields present in the device, probably due to the proximity to the ferromagnetic Ni contacts (see Supporting Information). As an ensemble is used and field inhomogenities are present, lines are expected to be of Gaussian shape envelope. The linewidths in Fig. 3(a) are much broader in the electrical case compared to the optically detected lines. We attribute this to a mismatch in the detection volumes for both techniques in combination with the residual magnetization of the Ni contacts. As the fluorescence light is not spatially filtered in case of the electrical readout, the detected signal may differ in position compared to the ODMR measurements. Nonetheless, data recorded at a different position shown in Fig. 3(c) suggests similar linewidths for PDMR and ODMR and thus proves that broadening in Fig. 3(a) is not due to the PDMR technique (see Supporting Information). To check that the measured signal originates from V2 centers, we measure the ground state ZFS via Zeeman splitting measurements by observing the resonances at various magnetic fields. As depicted in Fig. 3(b), the ZFS is found by fitting the model function to the magnetic field dependence of the resonances. Thereby, is the effective electron Landé factor for V, µ is the Bohr magneton and is a magnetic field accounting for the device internal fields. With this, we find 69.0 and 69.1 for the optically and electrically detected case, respectively. The factors found by the fit are 2.02 for ODMR and 2.03 for PDMR, while the offset field is 0.4 and 3.0 , respectively. The data presented corroborate that the signal originates from V2 centers. As shown in Fig. 3(d), the PDMR signal is located in the same area where the two-photon photocurrent contribution was found in Fig. 2(d).
However, we find the sign of the PDMR signal to be dependent on the location within the device as can be seen in Fig. 3(d). We tentatively attribute this to a change in the Fermi level in the device caused by charge state and ionization processes of surrounding defects 47. As a result, we cannot clearly determine if excitation from the ES or MS is responsible for the observed PDMR effect in the present device.
Next, we demonstrate coherent control, which is at the heart of advanced quantum control protocols. To this end, we first initialize the GS spin population into the 1/2 subspace via optical excitation. Subsequently a RF driving pulse of variable length to the 1/2 3/2 transition is applied. Finally the spin state is read out either optically or electrically using the next laser pulse. The latter at the same time ensures that the system is re-initialized for the following cycle. Experimental results for both ODMR and PDMR recorded under identical measurement conditions are shown in Fig. 4(a). We observe Rabi oscillations with essentially identical oscillation frequency and same-order decay times from both detection methods, which indicates that PDMR has no major detrimental effect on dephasing of the continuously driven system. We further record the Rabi oscillation frequency as a function of RF field strength and observe the expected linear increase (see Fig. 4(b)). This proves that the PDMR of the V spin state in SiC allows for coherent spin manipulation and readout of the ground state and thus fulfills the fundamental requirements for more complex quantum control schemes.
To evaluate the performance of the PDMR technique, we performed a parameter dependency study (see Supporting Information). We find a ten-fold increase in SNR in ODMR compared to PDMR after normalizing to the same measurement time. In addition, the PDMR contrast is around one order of magnitude smaller than the ODMR contrast with the current device. While PDMR amplitudes are in the range of , the mean dc background current measured by an oscilloscope parallel to the lock-in amplifier is on the order of a few . This results in a typical contrast of . On the other hand, ODMR measurements yield a contrast of around . The background current mainly consists of the resistive current through the device due to the bias. The laser induced photocurrent also contributes to the background, but due to the pulsed type of measurement is decreased by the duty cycle. However, our measurements suggest that we are limited by the current experimental conditions and that multiple parameters can still be optimized (see Supporting Information). Especially with increasing laser power the ODMR contrast saturates, whereas no saturation behavior is observed for PDMR yet. This is consistent with findings for NV ensembles in diamond 23. Furthermore, refining the measurement technique and device structure can potentially improve SNR. A large contribution to the noise floor is stray RF fields. We anticipate a gain in SNR by improving the device structure to be more resilient against parasitic RF coupling. In addition, the stepwise measurement was done in a conservative way and seconds of settling time between magnetic field steps were chosen in order to reach a quasi-static situation, while lock-in integration time was set to . Using a real magnetic-field sweep or frequency-modulated RF field will speed up signal accumulation. However, due to the RF-frequency-dependent stray currents and no possibility to directly sweep the magnetic field in our experimental conditions, we have not incorporated such techniques yet. Moreover, changes to the doping profile may allow to enhance carrier extraction efficiency, but may come with the cost of an increase in background photocurrent. As the large bandgap hinders a two-photon band-to-band excitation with a laser, the background photocurrent is likely generated by excitation of other intra-band defects created besides the V ensemble during the electron irradiation. As the background limits transimpedance gain, a trade-off between signal extraction efficiency and background has to be found. Another parameter is device geometry, e.g. channel width and thickness of the active layer. By this, the detection volume might be enlarged and leakage currents further reduced. Interestingly, only a small area within the aperture shows contribution to PDMR, although the details of the process have to be understood first. To this end, we suggest to measure the dependence of the signal on excitation laser wavelength and pulse length, which might give insight into the ionization process and may ultimately improve readout fidelity and state preparation 48, 49. Since we have shown that coherent spin control of V can be combined with PDMR, phase interferometry type sensing protocols can be utilized, which can boost sensitivity in metrology applications by many orders of magnitude 50, 51.
In summary, we have demonstrated photo-electrical readout of a V spin ensemble in a 4H-SiC metal-semiconductor-metal device under ambient conditions. We also report electrically detected spin coherence of this ensemble. This underlines the great potential of SiC and PDMR for quantum applications. The availability of large wafer production and processing techniques are very promising to future integration of electrical quantum devices at an industrially relevant scale. Advanced fabrication techniques can be used to integrate \latine.g. high-performance CMOS transimpedance amplifiers on-chip 52. This would allow miniaturization and quantum device integration into a classical circuit design. Even integration of the optical light source might be feasible in the future 53. Altogether, this work provides a first step towards integrated electrical quantum devices in 4H-SiC for quantum technology.
3 Author contributions
The initial planning of the project was done by M.N., M.W., S.-Y.L, N.T.S. and J.W.. J.U-H. and N.T.S. designed the device structure and performed the sample growth. R.S. fabricated the device. S.O., T.O. and J.I. planned and performed electron irradiation. M.N. designed and performed all experiments. M.N., T.R., M.W., A.M., N.M., Y-C.C., S.-Y.L and J.W. analyzed the data. The manuscript was written by M.N., M.W., T.R., R.S. and J.W. with contribution from all of the authors.
4 Acknowledgments
The authors thank Florian Kaiser for his valuable help in preparing the manuscript. We acknowledge financial support by the EU (ASTERIQS and ERC SMeL), BMBF (BrainQSens), the Max Planck Society, the Volkswagen Foundation, the Swedish Research Council (VR 2016-04068 and VR 2016-05362), the Carl Tryggers Stiftelse för Vetenskaplig Forskning (CTS 15:339), the Swedish Energy Agency (43611-1), the Knut and Alice Wallenberg Foundation (KAW 2018.0071), the Korea Institute of Science and Technology institutional programs (2E27231, 2E29580) and the Japan Society for the Promotion of Science KAKENHI (17H01056).
5 Abbreviations
CB – conduction band
ES – excited state
GS – ground state
ISC – intersystem crossing
MS – metastable state
MSM – metal-semiconductor-metal structure
NV – nitrogen-vacancy center in diamond
ODMR – optically detected magnetic resonance
PDMR – photocurrent detected magnetic resonance
RF – radiofrequency
SiC – silicon carbide
SNR – signal-to-noise ratio
TIA – transimpedance amplifier
VB – valence band
V, V – negatively charged silicon-vacancy (at cubic lattice site)
ZFS – zero field splittings
Supporting Information
6 Supporting information
6.1 Sample growth and fabrication details
Different layers were grown by chemical vapor deposition (CVD) on off-axis n-type 4H-SiC substrate. The first layer grown is a thick semi-insulating V-doped layer followed by a n*-* layer () with a free carrier concentration of at room temperature. The top n*++*-type N-doped contact layer is thick with a doping concentration of .
Fig. S1(a) shows the sample layout before structuring. While the Ni layer serves as a Schottky contact in the final device, it is also used as an etching mask during the fabrication process. All dry etching steps are performed using an ICP-RIE with SF6/O2 gas mixture, which realizes high etching selectivity of SiC over Ni. In the first step, all Ni outside the device region is removed. The sample is then plasma-etched \approx$$11\text{\,}\mathrm{\SIUnitSymbolMicro m} deep, which removes the n*++* layer and the n*-* layer and stops in the semi-insulating layer (Fig. S1(b)). During this step, the device region is protected by the residual Ni layer. Subsequently, Ni is removed in a rectangular region between the two contact pads of the device. This allows to etch the n*++* layer in this region by a short SF6/O2 ICP-RIE plasma step. The etching depth is chosen to be roughly twice the thickness of the n*++* layer, ensuring that it is completely removed. Finally, gold pads are deposited on both contacts for wirebonding, resulting in the final device as depicted in Fig. S1(d).
6.2 – Characteristics of the device used
The – characteristics of the device have been measured before and after electron irradiation. Note that these were measured on different experimental setups. For the measurement before irradiation, a source measure unit (SMU, Keithley, 487) with a manual probe station was used. Measurements after irradiation were performed with the PDMR setup using a SMU (Keithley, 2636B). The sample was mounted on a PCB sample holder. Connections between sample and PCB were wirebonded.
As shown in Fig. S2(a), the device shows rectifying behavior at positive and negative bias conditions. Thus, the contacts are assumed to be Schottky type. Then the sample has been irradiated by electrons with a dose of and an energy of . The measurement of the irradiated device clearly shows over 2 orders of magnitude less conductivity compared to the non-irradiated device (see Fig. S2(b)), which we attribute to the doping compensation due to irradiation-induced defects 46.
6.3 Position mapping of PDMR signal
To map the position of the obtained PDMR signal to the device structure, we utilize laser scanning. Thereby we subsequently acquire PDMR signal and fluorescence emission of the V ensemble. The fluorescence locates the device within the given scan range of as shown in Fig. S3. Because the optical detection is performed without spatial filtering, a slight offset in position may exist.
All measurements in the main text have been performed at a fixed depth for consistency. Crossections of photocurrent and PDMR signals are given in Fig. S4. The -slice shows that both photocurrent and PDMR amplitude are dependent on the focal position. The -slices show a thin strip (marked orange) of effective photocurrent generation that evolves to a larger area when defocusing (marked red). When the focus is inside the device, we do not find a PDMR signal. We attribute this finding to a small excitation volume, which results in a too small number of defects involved in the PDMR process. As increasing the excitation area, we pick up a measureable PDMR signal. However, due to the decrease in laser power density, the signal does not saturate. At the moment, it is unclear to us why this process only appears at the center of the device. A convolution of excitation volume and active area should be the expected result.
6.4 Parameter dependencies: Bias voltage, laser power and RF power
Fitting a single resonance peak in a PDMR measurement to the m_{s}=$$+1/2\leftrightarrow$$+3/2 transition gives information on the signal amplitude, linewidth, resonance frequency and the offset signal. The offset signal is mainly caused by stray RF field. Fig. S5 compares the dependency of ODMR and PDMR signal, on bases of amplitude, linewidth and resonance frequency when bias, laser power and RF power are changed. Note that although measurements have been performed under the same conditions for ODMR and PDMR, a slight offset in detected volume is possible (see discussion in main text). PDMR signals at small laser or RF powers as well as small bias voltages show low SNR and thus larger errorbars. Errorbars are obtained from standard error of least-square fitting, neglecting the noise contribution at each measurement point.
The bias voltage does not affect the ODMR signals. On the other hand, the PDMR amplitude increases monotonically without saturating. The applied bias determines the charge extraction efficiency, and larger bias is expected to increase the measured signal amplitude. Note that linewidth for ODMR and PDMR are similar. A small shift of resonance frequency dependent on bias is visible for PDMR (see Fig. S5(c)), but not in ODMR. This shift appears in the low bias regime in which the SNR is poor. At this moment, we do not have an explanation for this behavior.
The incident laser power does change neither linewidth nor resonance frequency. However, the fitted peak amplitude increases for both ODMR and PDMR. This observation is consistent with the suggested mechanism for the PDMR for the V in SiC because stronger optical excitation will enhance the photo-ionization probability (see Fig. 1(a)-(c) of the main text). Note that laser power dependence suggests a saturation behaviour for ODMR, while no saturation could be achieved in the PDMR case.
Larger RF power increases linewidth of the magnetic resonance due to power broadening. In case of PDMR, a larger shift in resonance frequency is only visible for the point at smallest RF power at which signal is still picked up in PDMR. At this data point, the signal has very low amplitude. The amplitudes of the PDMR and ODMR signals increase with larger RF power. Assuming inhomogeneous broadening, increasing the RF power increases the excitation bandwidth and thus more defects contribute to the signal. No saturation of the microwave transition is visible. Note that the point of highest applied RF power is already measured in the RF amplifier compression regime.
6.5 Discussion on PDMR contrast, SNR and sensitivity
In a typical ODMR experiment, the contrast is defined as the spin-dependent fluorescence change at resonance to the off resonance fluorescent signal PL (baseline):
[TABLE]
As this definition fits the requirement, as long as an absolute signal is acquired, this is not directly applicable in case of lock-in detection, as only a change in an acquired quantity is detected. In other words, the absolute measure of the given input is lost, which is essential for the former definition of contrast, and only changes modulated by the lock-in frequency are detected. Nevertheless, the detected lock-in signal contains a constant offset. Here, as the device is in close proximity to the co-planar waveguide, the offset is dominated by a frequency-dependent coupling of the RF field to the device, which is modulated exactly at the lock-in frequency. However, the use of this offset in the definition of contrast as the baseline would lead to a non-physical interpretation of PDMR contrast. Hence, one could give a device-specific contrast only, which compares the amount of RF coupling for a given RF frequency with PDMR signal. Based on the original definition of contrast, we further extend this definition by comparing the amplitude to the maximum acquired signal as follows:
[TABLE]
Here, BG is the fluorescence background or dc offset of the PDMR signal and A is the ODMR or PDMR amplitudes. By this definition, the maximum achievable contrast by fluorescence is limited to 100%, resulting in a more meaningful quantity. We simultaneously monitor the detected PDMR signal by lock-in detection and use an oscilloscope in parallel to the lock-in amplifier in order to detect the mean magnitude of the dc signal. This dc offset additionally to the previous signals is composed of bias and photocurrent contribution. The lock-in allows to detect a spin dependent change with maximum sensitivity while the oscilloscope is used to extract the dc offset as a baseline. In particular, we use the oscilloscopes mean value within a integration window to get the dc offset for each magnetic field point. We then take the mean value of these points as dc offset. In this recorded data, the PDMR amplitude is also contained within the data for on-resonance points. As the PDMR and ODMR amplitudes are very small compared to the dc offset (4 orders of magnitude), the contribution is negligible. The same argument holds for the difference between definitions in Eq. S1 and Eq. S2. Thus in case of low relative amplitudes, our extended definition of contrast is comparable to prior work.
Next, we analyze the dependence of contrast and SNR on the experimental conditions. To correct for differences in measurement time we normalize the SNR to . The value for this time-normalized is then calculated by
[TABLE]
where is the total measurement time and SNR the signal-to-noise ratio calculated by dividing the fitted amplitude by the obtained standard deviation noise at (see Fig. S7 and calculation of dc magnetic field sensitivity).
In ODMR measurements, the contrast and do not depend on the bias, while they do for PDMR as shown in Fig. S6(a) and (b). In PDMR, both contrast and , are improved for larger bias voltages. We attribute this to a better extraction efficiency of free electrons and holes in case of PDMR. In terms of contrast a saturating behavior is visible for larger biases. As can be seen in Fig. S5(a), the amplitude is still increasing, thus the dc offset must increase more quickly then the signal in this regime. In case of laser power dependence, we see that ODMR contrast decreases for high laser powers, while the PDMR contrast still increases (see Fig. S6(c)). The time-normalized SNR shown in Fig. S6(d) saturates for ODMR, whereas SNR in the PDMR case still increases with laser power. If we vary the applied RF power, a clear rise in contrast is visible in both measurement techniques, as depicted in Fig. S6(e). is increasing for both PDMR and ODMR with applied RF power. However, larger RF power leads to larger noise for PDMR due to the RF coupling. The gain in is thus bigger for ODMR than for PDMR.
In the following, we calculate the dc magnetic field sensitivity. For this we use the ODMR and PDMR data shown in Fig. 3(c) in the main text.
The sensitivity is given by comparing the signal power to the noise spectral power. We estimate the noise by using data points at least 3 apart from the resonance (see Fig. S7) and calculating the standard deviation of these data points. This way, we extract a noise level of . Signal-to-noise ratio is then obtained by dividing the PDMR resonance amplitude by the noise level. The measurement time per point is for this PDMR measurement, resulting in a noise spectral density of . The slope of the Gaussian peak is maximum at distance, related to the FWHM by (see Fig. S7). Thus the position of the steepest slope can be found by the amplitude and FWHM of the fitted peak and we find a maximum slope of . From this, we calculate a magnetic field sensitivity of .
For the ODMR, we find a noise level of within a measurement time of per point. With a slope of we calculate the sensitivity to be .
Note that we have not reached the saturation of PDMR signal because of the limitation of the laser power. Bias and RF power dependence also promise further improvement in SNR and sensitivity. In addition, while the PDMR contrast is 1/10 of the ODMR contrast, in theory, comparable values might be achievable, as the underlying ISC process is the same. Thus the SNR, sensitivities and contrast given in the main text and the supporting information have to be understood as a lower achievable limit.
6.6 Local magnetic fields variations inside the device
In order to check for magnetic fields within the device likely introduced by magnetization of the Ni contacts, we perform ODMR measurements at different depths and x-positions and extract the resonance frequency. The results are shown in Fig. S8. As the lines can shift a couple of , magnetic field offsets of a few Gauss appear to be plausible in the device structure. This position-dependent magnetic field might cause the difference in the external fields between PDMR and ODMR because there might be a slight difference in detection volume position.
The reference list from the paper itself. Each links out to its DOI / PubMed record.
- 1Degen \latin et al. 2017 Degen, C.; Reinhard, F.; Cappellaro, P. Quantum sensing. Reviews of Modern Physics 2017 , 89
- 2Casola \latin et al. 2018 Casola, F.; van der Sar, T.; Yacoby, A. Probing condensed matter physics with magnetometry based on nitrogen-vacancy centres in diamond. Nature Reviews Materials 2018 , 3 , 17088
- 3Atatüre \latin et al. 2018 Atatüre, M.; Englund, D.; Vamivakas, N.; Lee, S.-Y.; Wrachtrup, J. Material platforms for spin-based photonic quantum technologies. Nature Reviews Materials 2018 , 3 , 38–51
- 4Yang \latin et al. 2016 Yang, S.; Wang, Y.; Rao, D. D. B.; Hien Tran, T.; Momenzadeh, A. S.; Markham, M.; Twitchen, D. J.; Wang, P.; Yang, W.; Stöhr, R.; Neumann, P.; Kosaka, H.; Wrachtrup, J. High-fidelity transfer and storage of photon states in a single nuclear spin. Nature Photonics 2016 , 10 , 507–511
- 5Nagy \latin et al. 2018 Nagy, R. \latin et al. High-fidelity spin and optical control of single silicon vacancy centres in silicon carbide. ar Xiv:1810.10296 [cond-mat, physics:quant-ph] 2018 , ar Xiv: 1810.10296
- 6Humphreys \latin et al. 2018 Humphreys, P. C.; Kalb, N.; Morits, J. P. J.; Schouten, R. N.; Vermeulen, R. F. L.; Twitchen, D. J.; Markham, M.; Hanson, R. Deterministic delivery of remote entanglement on a quantum network. Nature 2018 , 558 , 268–273
- 7Gruber 1997 Gruber, A. Scanning Confocal Optical Microscopy and Magnetic Resonance on Single Defect Centers. Science 1997 , 276 , 2012–2014
- 8Jelezko \latin et al. 2004 Jelezko, F.; Gaebel, T.; Popa, I.; Gruber, A.; Wrachtrup, J. Observation of Coherent Oscillations in a Single Electron Spin. Physical Review Letters 2004 , 92
