The ZEUS Forward Plug Calorimeter with Lead-Scintillator Plates and WLS Fiber Readout
A. Bamberger, S. B\"ottcher, I. Bohnet, J.P. Fern\'andez, F. Goebel,, P. G\"ottlicher, A. Gabareen, G. Garc\'ia, N. Gendner, R. Graciani, M., Hauser, D. Horstmann, M. Inuzuka, M. Kasemann, B. L\"ohr, R. Lewis, H. Lim,, L. Lindemann, P. Markun, M. Mart\'inez, T. Neumann

TL;DR
This paper describes the design, construction, and testing of a forward plug calorimeter for the ZEUS detector at HERA, utilizing lead-scintillator plates and wavelength-shifter fiber readout, with calibration and performance results from CERN test beams.
Contribution
It introduces a novel shashlik calorimeter design with wave length shifter fiber readout for the ZEUS detector, including calibration and testing procedures.
Findings
Successful calibration with $^{60}$Co source
Effective detection of electrons, muons, and pions in 10-100 GeV/c range
Calorimeter performance validated with CERN test beams
Abstract
A Forward Plug Calorimeter (FPC) for the ZEUS detector at HERA has been built as a shashlik lead-scintillator calorimeter with wave length shifter fiber readout. Before installation it was tested and calibrated using the X5 test beam facility of the SPS accelerator at CERN. Electron, muon and pion beams in the momentum range of 10 to 100 GeV/c were used. Results of these measurements are presented as well as a calibration monitoring system based on a Co source.
Peer Reviews
No public reviews on file for this paper yet. If you reviewed it on a platform where reviews are public (OpenReview, ICLR, NeurIPS, ICML), you can paste yours below so the community can read it here.
Videos
No videos yet. Explain this paper in a talk, walkthrough, or lecture? Add one.