# Validation of the Primerdesign Quantitative Allele Specific Amplification Kit for the Detection of JAK2V617F Mutation

**Authors:** Deborah Vaz, Tshiphiri Netshidzivhani, Johan Potgieter

PMC · DOI: 10.1002/jcla.70180 · Journal of Clinical Laboratory Analysis · 2026-02-19

## TL;DR

This study validates a new kit for detecting a specific JAK2 gene mutation linked to myeloid cell proliferation, showing it is highly accurate and reliable.

## Contribution

The study confirms the Primerdesign Quasa kit's effectiveness for JAK2V617F mutation detection and its potential for quantitative analysis.

## Key findings

- The Quasa kit showed 100% concordance with real-time PCR for JAK2V617F detection.
- The kit demonstrated high precision with reproducible results across multiple tests.
- Analytical sensitivity was confirmed at 0.1% using reference panels.

## Abstract

Janus Kinase 2 (JAK2) is a tyrosine kinase involved in cellular signalling. A point mutation in codon 617 of JAK2 (JAK2V617F) causes a gain‐of‐function effect that stimulates proliferation of myeloid cells. The aim of this study was to evaluate the Primerdesign quantitative allele‐specific amplification (Quasa) kit for the detection of JAK2V617F.

Specimens previously evaluated using real‐time PCR with melting curve analysis were analysed using the Quasa kit on the Bio‐Rad CFX 96 platform. Results of the two PCR tests were compared to evaluate the accuracy of the kit. For intra‐assay precision, samples were analysed in duplicate on the same run, and for inter‐assay variation, the same known samples were tested on three non‐consecutive days. The analytical sensitivity and quantitative analysis of the assay were determined using the World Health Organization (WHO) 1st International Reference Panel for Genomic JAK2V617F (United Kingdom Official Medicines Control Laboratory) and the United Kingdom National External Quality Assessment Service (UK NEQAS) results of their JAK2 p.val617phe (V617F) Mutation Status Programme.

Concordance of the qualitative test results between the test methods was 100%. Precision experiments confirmed repeatability and reproducibility. Analytical sensitivity was confirmed at 0.1%.

The PrimerDesign Quasa kit for the detection of JAK2V617F is a sensitive and reliable assay that yields reproducible qualitative results. The kit is commercially available and has, in addition, the potential for quantitative analysis when samples are analysed in duplicate. This kit assay validation may be valuable to laboratories offering or interested in offering JAK2V617F mutational testing.

The PrimerDesign Quasa kit demonstrates efficacy as a reliable assay for the detection of JAK2V617F mutation, exhibiting potential for quantitative analysis when samples are analysed in duplicate. This assay validation information may prove valuable to laboratories seeking to implement a simplified JAK2V617F mutational test.

## Linked entities

- **Genes:** JAK2 (Janus kinase 2) [NCBI Gene 3717]

## Full-text entities

- **Genes:** JAK2 (Janus kinase 2) [NCBI Gene 3717] {aka JTK10}
- **Mutations:** JAK2V617F, V617F

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC13042390/full.md

## Figures

4 figures with captions in the complete paper: https://tomesphere.com/paper/PMC13042390/full.md

## References

24 references — full list in the complete paper: https://tomesphere.com/paper/PMC13042390/full.md

---
Source: https://tomesphere.com/paper/PMC13042390