## TL;DR

This study assesses the isomer purity of synthetic phosphatidylethanol standards and compares them to natural variations in blood samples to improve alcohol consumption testing accuracy.

## Contribution

The study introduces a new method using CID/OzID to evaluate isomer purity in PEth reference materials and compares them to clinical samples.

## Key findings

- Synthetic PEth reference materials have >95% regioisomeric purity.
- Natural isomer distributions in blood samples range from 88.8% to 98.85%.
- Variation in isomer composition does not significantly impact clinical classification.

## Abstract

The direct blood‐alcohol biomarker phosphatidylethanol (PEth), especially its most abundant analogue 1‐palmitoyl‐2‐oleoyl‐sn‐phosphatidylethanol (PEth 16:0/18:1) has gained increasing relevance in clinical and forensic applications for assessing alcohol consumption. Accurate quantification of PEth is essential to reliably differentiate between abstinence, moderate alcohol consumption and excessive alcohol intake. Measurement accuracy of PEth 16:0/18:1 by well‐established liquid chromatography–tandem mass spectrometry (LC‐MS/MS) approaches such as multiple reaction monitoring (MRM) can be confounded by the presence of the regioisomer 1‐oleoyl‐2‐palmitoyl‐sn‐phosphatidylethanol (PEth 18:1/16:0) in samples and synthetic reference standards. To address this measurement uncertainty, we conducted a new assessment of the isomeric composition of six currently available reference materials from four suppliers using collision‐induced dissociation/ozone‐induced dissociation (CID/OzID). Examination of these synthetic compounds found a high degree of regioisomeric purity of > 95%. Thus verified, the relative abundance of two key LC–MS/MS transitions were compared across a range of collision energies for both reference materials and an exemplary set of 10 dried blood spot case samples. These findings suggest a significantly wider range of natural isomer distributions spanning both higher and lower regiochemical composition (88.8%–98.85%) than the reference materials but within a range that would not significantly impact clinical classification.

This study examines the isomeric composition of PEth reference materials and compares it with the natural variation in isomer distribution found in blood samples.

## Linked entities

- **Chemicals:** phosphatidylethanol (PubChem CID 52946593)

## Full-text entities

- **Chemicals:** PEth (MESH:C051521), Ozone (MESH:D010126), 1-oleoyl-2-palmitoyl-sn-phosphatidylethanol (-), alcohol (MESH:D000438)

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC13040422/full.md

## Figures

4 figures with captions in the complete paper: https://tomesphere.com/paper/PMC13040422/full.md

## References

16 references — full list in the complete paper: https://tomesphere.com/paper/PMC13040422/full.md

---
Source: https://tomesphere.com/paper/PMC13040422