# Associated uncertainty estimation during the validation process of TCID50 and FRNT neutralization assays against SARS-CoV-2 variants, used in population surveillance research and correlates of protection

**Authors:** Edgar Reyna-Rosas, Milton Nieto-Ponce, Andrea Palencia-Reyes, Carlos Blancas-Ruíz, Claudia Carranza, Martha Torres, Horacio Zamudio-Meza

PMC · DOI: 10.3389/fimmu.2026.1768395 · Frontiers in Immunology · 2026-03-18

## TL;DR

This study evaluates the uncertainty in two SARS-CoV-2 neutralization assays to improve their reliability for vaccine research and population surveillance.

## Contribution

The study provides a validated framework for nAb quantification compliant with international standards, emphasizing uncertainty estimation and quality control.

## Key findings

- FRNT showed higher sensitivity but greater inter-analyst variability compared to TCID50MN.
- Both assays demonstrated high diagnostic performance for detecting neutralizing activity against SARS-CoV-2 variants.
- Standardization and analyst training are critical to reducing variability and improving reliability.

## Abstract

Neutralizing antibody (nAb) assays are essential for evaluating antibody-mediated immune response against SARS-CoV-2, in the context of efficacy and potency of vaccines, as well as population-level surveillance. This study aimed to estimate the associated uncertainty during the validation of two neutralization assays—50% tissue culture infectious dose microneutralization (TCID50MN) and fluorescent focus reduction neutralization test (FRNT)—to measure activity of nAbs against SARS-CoV-2 variants of concern (VOCs) within an ISO/IEC 17025:2017 accredited laboratory. Human serum samples were tested against five SARS-CoV-2 variants (Wuhan, BA.2, BA.5, XBB.1, and JN.1) using vesicular stomatitis virus (VSV) pseudotyped viruses. The validation process was based on international guidelines for the suitability and validation of analytical methods. Both assays demonstrated high diagnostic performance to detect neutralizing activity, where FRNT yielded higher sensitivity but greater inter-analyst variability than TCID50MN. These results highlight the importance of identifying the level of impact of factors associated with obtaining a result, such as the training of analysts and the standardization of the test. This study establishes a validated framework for nAb quantification in compliance with international standards. The declaration of associated uncertainty to each method, along with sustained internal quality control, strengthens the diagnostic capacity of these assays in clinical research of correlates of protection and immunity induced by vaccination, in addition to reinforcing transparency and regulatory compliance, as critical elements in decision-making.

## Linked entities

- **Diseases:** SARS-CoV-2 (MONDO:0100096)

## Full-text entities

- **Species:** Homo sapiens (human, species) [taxon 9606], Vesicular stomatitis virus (species) [taxon 11276], Severe acute respiratory syndrome coronavirus 2 (no rank) [taxon 2697049]

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC13038988/full.md

## References

38 references — full list in the complete paper: https://tomesphere.com/paper/PMC13038988/full.md

---
Source: https://tomesphere.com/paper/PMC13038988