# Plug-based bail-out strategy for leaflet tear after mitral transcatheter edge-to-edge repair: a case report

**Authors:** Naoki Nishiura, Shunsuke Kubo, Kohei Osakada, Takeshi Maruo, Mitsuru Abe

PMC · DOI: 10.1093/ehjcr/ytag218 · European Heart Journal. Case Reports · 2026-03-26

## TL;DR

This case report describes a novel transcatheter bail-out strategy using a plug and additional device to treat a leaflet tear after a heart repair procedure.

## Contribution

A new plug-based bail-out strategy is proposed for leaflet tears following mitral TEER.

## Key findings

- A leaflet tear after TEER was successfully managed using a PASCAL Ace device and an Amplatzer Vascular Plug II.
- The plug-based strategy reduced MR jet to mild without requiring surgery.
- This approach may be considered when additional TEER devices alone are insufficient.

## Abstract

Mitral transcatheter edge-to-edge repair (TEER) is a safe and widespread treatment approach for severe mitral regurgitation (MR). However, rare but serious device-related complications, including single leaflet device attachment, perforation, and leaflet tear, may occur, often requiring surgical correction.

An 82-year-old man with congestive heart failure and ischaemic cardiomyopathy underwent mitral TEER using MitraClip XTW clip for severe functional MR. Two days after the procedure, MR recurrence due to a leaflet tear was observed. Given the patient’s advanced age and reduced left ventricular function, our cardiac team decided to perform a transcatheter bail-out procedure. First, the tear was converted to a hole shape by implanting a PASCAL Ace device (Edwards Lifesciences) lateral to the XTW, as this device has a lower risk of leaflet damage compared to the MitraClip device. Then, Amplatzer Vascular Plug II (AVP II) was deployed into the hole, with its mid-lobe positioned in contact with the devices and leaflets. After releasing the AVP II, the MR jet reduced to mild.

An optimal bail-out strategy for leaflet tears has not yet been established. When it is difficult to sufficiently cover the leaflet tear using only an additional TEER device, the use of a plug with additional TEER devices can be considered a bail-out strategy.

## Linked entities

- **Diseases:** congestive heart failure (MONDO:0005009)

## Full-text entities

- **Diseases:** ischaemic cardiomyopathy (MESH:D009202), MR (MESH:D008944), congestive heart failure (MESH:D006333), leaflet tear (MESH:D012167)
- **Species:** Homo sapiens (human, species) [taxon 9606]

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC13034730/full.md

## Figures

4 figures with captions in the complete paper: https://tomesphere.com/paper/PMC13034730/full.md

## References

5 references — full list in the complete paper: https://tomesphere.com/paper/PMC13034730/full.md

---
Source: https://tomesphere.com/paper/PMC13034730