# A novel AI-enhanced microwave sensor employing defected ground structure for non-invasive glucose monitoring

**Authors:** Fikret Alpay Tekşen, Seda Aygül, Berker Çolak, Fatih Özkan Alkurt, Muharrem Karaaslan, Yakup Hameş, Edik Rafaliov, Tatjana Gric

PMC · DOI: 10.1038/s41598-026-40171-9 · Scientific Reports · 2026-02-19

## TL;DR

This paper introduces a new non-invasive glucose monitoring sensor using AI-enhanced microwave technology for more accurate and comfortable diabetes management.

## Contribution

A novel chaotic defected ground structure microwave sensor with enhanced sensitivity for non-invasive glucose monitoring.

## Key findings

- The sensor achieved high sensitivity of 0.950 MHz/(mg/dL) in detecting glucose levels.
- It successfully differentiated clinically relevant glucose concentrations (50–200 mg/dL) using tissue-mimicking phantoms.
- The chaotic DGS design improved tissue penetration and sensitivity to dielectric changes.

## Abstract

Diabetes is a chronic disease that affects millions of people worldwide and significantly reduces quality of life. One of the most critical aspects of managing this condition is the accurate, continuous, and reliable monitoring of blood glucose levels. Fluctuations in glucose concentration can lead to both short-term complications and long-term irreversible organ damage. Currently, traditional glucose monitoring methods rely mainly on blood samples obtained through finger-pricking. While these methods are accurate, their invasive nature reduces user comfort, causes pain, poses a risk of infection, and negatively affects patient adherence in the long run. In response to these limitations, non-invasive glucose monitoring technologies, particularly those based on microwave and radio frequency (RF) sensor systems, have gained increasing attention. However, most reported systems still face challenges in achieving high sensitivity and stability under realistic physiological conditions. In this study, we introduce a novel hexagonal microstrip patch antenna with a chaotic Defected Ground Structure (DGS) based on a Duffing chaotic attractor, specifically designed for non-invasive blood glucose sensing. Unlike conventional DGS-based sensors, our chaotic DGS approach enhances tissue penetration and significantly improves sensitivity to subtle dielectric variations caused by glucose concentration changes. The sensor, optimized for finger placement, operates in the 4–5 GHz range to ensure effective tissue coupling. Experimental validation using multi-layer tissue-mimicking phantoms demonstrated the sensor’s ability to differentiate clinically relevant glucose levels (50–200 mg/dL), achieving a high sensitivity of 0.950 MHz/(mg/dL).

## Linked entities

- **Diseases:** Diabetes (MONDO:0005015)

## Full-text entities

- **Chemicals:** glucose (MESH:D005947)

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC13021957/full.md

## Figures

11 figures with captions in the complete paper: https://tomesphere.com/paper/PMC13021957/full.md

## References

17 references — full list in the complete paper: https://tomesphere.com/paper/PMC13021957/full.md

---
Source: https://tomesphere.com/paper/PMC13021957