# Blockbuster Laryngeal Mask Airway Versus Endotracheal Tube for Airway Management in Off-Pump Cardiothoracic Surgery: A Randomized Controlled Study

**Authors:** Kavya Rajagopal, Bharat Choudhary, Kriti Bhandari, Abhinav Singh, Shikha Soni, Rakesh Karnawat

PMC · DOI: 10.7759/cureus.103946 · Cureus · 2026-02-20

## TL;DR

This study compares a new airway device to traditional tubes in heart surgery, finding the new device faster and safer.

## Contribution

The study evaluates the Blockbuster LMA as an alternative to endotracheal tubes in off-pump cardiothoracic surgery.

## Key findings

- Blockbuster LMA provided quicker airway establishment compared to endotracheal tubes.
- Endotracheal tubes caused higher hemodynamic responses and more post-operative sore throats.
- Ventilatory parameters were similar between the two airway methods.

## Abstract

Background and aims

The increasing use of supraglottic airway devices has led to a shift in airway management practices. BlockBuster® Laryngeal Mask Airway (BLMA; Henan Tuoren Medical Device Co., Ltd., China) is a newer second-generation device, and its use in prolonged surgeries remains limited. Off-pump cardiothoracic surgeries are conventionally performed using endotracheal intubation, which may be associated with significant haemodynamic responses.

Methods

This prospective randomized study included 60 adult patients undergoing elective off-pump cardiothoracic surgeries, allocated into two groups of 30 each. Group A had the airway secured using a Blockbuster LMA, and Group B used an endotracheal tube. Time taken to achieve an effective airway, number of attempts, ease of insertion, intraoperative haemodynamic and ventilatory parameters, and post-operative complications were assessed.

Results

The time taken to achieve effective airway was significantly shorter in Group A compared to Group B (p<0.001). Haemodynamic parameters including heart rate, systolic blood pressure, diastolic blood pressure, and mean arterial pressure were significantly higher in Group B during the immediate period following airway securement (p<0.05). The incidence of post-operative sore throat was significantly higher in the endotracheal tube group (p<0.05). Ventilatory parameters were comparable between the two groups.

Conclusion

Blockbuster LMA is a suitable alternative to the endotracheal tube for airway management in patients undergoing off-pump cardiothoracic surgery, providing quicker airway establishment, better haemodynamic stability, effective ventilation, and fewer post-operative complications.

## Full-text entities

- **Diseases:** sore throat (MESH:D010612)
- **Chemicals:** Endotracheal Tube (-)
- **Species:** Homo sapiens (human, species) [taxon 9606]

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC13006104/full.md

## Figures

2 figures with captions in the complete paper: https://tomesphere.com/paper/PMC13006104/full.md

## References

18 references — full list in the complete paper: https://tomesphere.com/paper/PMC13006104/full.md

---
Source: https://tomesphere.com/paper/PMC13006104