# Development and biomechanical validation of a whole spine–thorax finite element model for quantitative biomechanical analysis

**Authors:** Junhua Li, Yaoshuai Yu, Yuanxun Lin, Hongwen Liu, Weixing Zhong, Lixin Tang, Diangu Chen, Yongliang Ye, Xiaoguang Lin, Tianzhao Tian, Yikai Li

PMC · DOI: 10.7717/peerj.20961 · PeerJ · 2026-03-18

## TL;DR

This paper presents a detailed 3D model of the spine and thorax validated against real data to study biomechanics under various conditions.

## Contribution

A high-fidelity finite element model of the whole spine–thorax complex with validation under realistic loading scenarios.

## Key findings

- The model accurately reproduced segmental moment–rotation behavior within experimental ranges.
- Frontal chest impact simulation results matched cadaveric data with low error percentages.
- The model provides a non-invasive platform for analyzing biomechanical responses under different conditions.

## Abstract

To develop a high-fidelity three-dimensional finite element model of the whole spine–thorax complex based on high-resolution computed tomography (CT) images of a healthy adult male, and to perform initial validation under representative loading conditions for quantitative analysis of load transmission, coupled motion, and stress distribution. We hypothesized that the model would reproduce published quasi-static segmental moment–rotation behavior and cadaveric thoracic impact responses within acceptable error ranges.

High-resolution CT data of one healthy adult Chinese male volunteer (25 years; 175 cm; 70 kg) were used to reconstruct detailed anatomical structures, including vertebrae, intervertebral discs, ribs, costal cartilage, sternum, ligaments, respiratory muscles, lungs, and heart. Material properties were assigned based on literature data, and nonlinear contacts were defined among articular and cartilaginous structures. Model validation was carried out using two scenarios: pure-moment loading of the T12–L1 functional spinal unit and a frontal chest impact simulation, with the numerical responses compared against available experimental and cadaveric data.

The T12–L1 moment–rotation curves agreed well with published biomechanical ranges, and the frontal impact simulation produced a peak force (3,270 N) and chest compression (79 mm) closely matching experimental results (3,453 N and 80 mm), with errors of 5.3% and 1.25%, respectively.

The finite element model reproduced static and dynamic responses of the spine–thorax complex within available experimental ranges for the loading conditions examined, providing an initial, non-invasive platform for investigating load transmission, coupled motion, and stress distribution under physiological, pathological, and interventional conditions.

## Linked entities

- **Species:** Homo sapiens (taxon 9606)

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC13005614/full.md

## Figures

7 figures with captions in the complete paper: https://tomesphere.com/paper/PMC13005614/full.md

## References

42 references — full list in the complete paper: https://tomesphere.com/paper/PMC13005614/full.md

---
Source: https://tomesphere.com/paper/PMC13005614