# Development of a colloidal gold immunochromatographic strip for the rapid detection of fowl adenovirus serotype 4 using prepared penton protein-specific monoclonal antibodies

**Authors:** Sisi Luo, Bingyi Yang, Jiaoling Huang, You Wei, Zhixun Xie, Xiaofeng Li, Aiqiong Wu, Zhihua Ruan, Sheng Wang, Yanfang Zhang, Meng Li, Liji Xie, Ming Yan, Weiwei Wang, Ping Wei

PMC · DOI: 10.3389/fvets.2026.1758143 · 2026-03-05

## TL;DR

This study developed a fast and accurate test strip using monoclonal antibodies to detect a deadly chicken virus, which could help control outbreaks.

## Contribution

A new colloidal gold immunochromatographic strip for rapid FAdV-4 detection using penton-specific monoclonal antibodies.

## Key findings

- Monoclonal antibodies 6B3 and 8G11 showed high specificity for FAdV-4 without cross-reactivity.
- The developed test strip detected FAdV-4 with 98.6% concordance compared to ELISA in clinical samples.
- The method achieved a detection sensitivity of 7.81 × 10⁴ TCID₅₀/0.1 mL within 15 minutes.

## Abstract

Fowl adenovirus serotype 4 (FAdV-4) is the primary pathogen responsible for hydropericardium-hepatitis syndrome (HHS) and is associated with high mortality rates (20–80%) in 3–6-week-old chickens. This study aimed to develop a rapid and specific method for detecting FAdV-4. Two monoclonal antibodies (mAbs 6B3 and 8G11) against the FAdV-4 penton protein were successfully generated using hybridoma technology, both of which exhibited high titers (1:100,000) and strong serotype specificity. Specificity analysis confirmed that these mAbs recognized 12 FAdV-4 isolates from diverse origins without cross-reactivity to other FAdV serotypes or common avian pathogens. On this basis, a colloidal gold immunochromatographic assay was developed; systematic optimization of its key parameters yielded an optimal labeling pH of 8.3, an antibody labeling concentration of 7.2 μg/mL, and optimal coating concentrations for the test line (T-line) and control line (C-line) of 2.5 mg/mL and 1.5 mg/mL, respectively. Performance evaluation of the method demonstrated that it achieved a detection sensitivity of 7.81 × 104 TCID₅₀/0.1 mL with a detection time of 15 min. Clinical sample validation revealed a positive concordance rate of 91.6%, a negative concordance rate of 100%, and an overall concordance rate of 98.6% relative to those of the ELISAs. The proposed colloidal gold immunochromatographic method offers advantages such as ease of operability, rapid visualization and high specificity and serves as a practical technical tool for onsite rapid diagnosis and epidemiological surveillance of FAdV-4 infection, thus it has high potential in the prevention and control of HHS.

## Full-text entities

- **Diseases:** FAdV-4 infection (MESH:D000257), HHS (MESH:D056486)
- **Chemicals:** gold (MESH:D006046)
- **Species:** Gallus gallus (bantam, species) [taxon 9031]

## Figures

10 figures with captions in the complete paper: https://tomesphere.com/paper/PMC12999416/full.md

---
Source: https://tomesphere.com/paper/PMC12999416