# Noninvasive Assessment of Hepatic Steatosis in Living Liver Donors

**Authors:** Iman Al-Saleh, Hamad Alashgar, Ali Albenmousa, Ruba Alsaeed, Madiha Jamal

PMC · DOI: 10.3390/diagnostics16050772 · Diagnostics · 2026-03-04

## TL;DR

This study evaluates noninvasive tools for detecting liver fat in liver donors, finding that CAP and MRI-PDFF are effective for screening and confirmation.

## Contribution

The study provides a practical diagnostic workflow for hepatic steatosis in liver donors using noninvasive methods.

## Key findings

- MRI-PDFF identified hepatic steatosis in 19.4% of donors.
- CAP had high sensitivity and negative predictive value for ruling out steatosis.
- CT showed high specificity but low sensitivity for detecting steatosis.

## Abstract

Background & Aims: The accurate, noninvasive assessment of hepatic steatosis is essential in living liver donor evaluation, where disease prevalence is low, and donor safety is paramount. This study evaluated commonly used noninvasive diagnostic tools for detecting hepatic steatosis in a real-world donor screening setting. Methods: We analyzed 108 living liver donor candidates (18–53 years) with complete MRI, CT, transient elastography (FibroScan®), and biochemical data obtained during routine donor evaluation. Hepatic steatosis was defined as an MRI-proton density fat fraction (PDFF) ≥5%, which served as the noninvasive reference standard. Diagnostic performance metrics, receiver operating characteristic (ROC) analyses, and correlations with serum fibrosis indices (FIB-4 and APRI) were assessed. Results: MRI-PDFF identified hepatic steatosis in 21 donors (19.4%). Controlled attenuation parameter (CAP), measured by transient elastography, demonstrated high sensitivity (90.5%) and negative predictive value (97.1%), supporting its role as a rule-out screening tool. CT showed excellent specificity (97.7%) but lower sensitivity (61.9%), consistent with a confirmatory role when MRI is unavailable. Serum fibrosis indices were generally low and did not correlate strongly with imaging-based steatosis. Conclusions: In the low-prevalence setting of living liver donor evaluation, CAP-based transient elastography provides effective noninvasive screening for hepatic steatosis, while MRI-PDFF serves as a confirmatory reference when indicated. These findings support a stepwise, clinically practical diagnostic approach that prioritizes donor safety and workflow efficiency.

## Full-text entities

- **Diseases:** fibrosis (MESH:D005355), Hepatic Steatosis (MESH:D005234)

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC12984876/full.md

## Figures

2 figures with captions in the complete paper: https://tomesphere.com/paper/PMC12984876/full.md

## References

30 references — full list in the complete paper: https://tomesphere.com/paper/PMC12984876/full.md

---
Source: https://tomesphere.com/paper/PMC12984876