# Finite element biomechanics of novel intramedullary nails with varying diameters for intertrochanteric femoral fractures with lateral wall injury

**Authors:** En Wu, Zhongjian Tang, Liucheng Wang, Haitao Liu, Zhiwei Peng, Yonghui Liang

PMC · DOI: 10.3389/fbioe.2026.1758146 · Frontiers in Bioengineering and Biotechnology · 2026-02-24

## TL;DR

This study compares new types of intramedullary nails for hip fractures and finds that a bionic nail (PFTBN) performs best in reducing stress and displacement in the bone.

## Contribution

The paper introduces and evaluates novel bionic intramedullary nails for hip fractures using finite element analysis.

## Key findings

- PFTBN showed the lowest peak stress and displacement in both reamed and unreamed conditions.
- Reaming increased nail-bone contact and reduced femoral stress concentration.
- Both PFTBN and II PFBN provided better stability than traditional PFNA.

## Abstract

This study aimed to compare the fixation performance differences between the traditional proximal femoral nail antirotation (PFNA), “II” proximal femoral bionic nail (PFBN), and proximal femoral total bionic nail (PFTBN) in the treatment of intertrochanteric femoral fractures complicated by lateral wall injury using finite element analysis. Additionally, it intended to explore the biomechanical effects of reamed versus unreamed techniques on these novel intramedullary nail devices.

Validated FEA models of intertrochanteric fractures (lateral wall injury) were constructed with 9 mm (unreamed) and 11 mm (reamed) medullary canals, followed by implantation of PFNA, “II” PFBN, or PFTBN. Under a vertical load of 2100 N, Von Mises Stress (VMS) and displacement of the femur and implants were quantified.

Under a vertical load of 2100 N, in the unreamed condition, the PFTBN exhibited the lowest peak stress and displacement among the three devices, followed by the “II” PFBN, while the traditional PFNA showed the poorest performance. After reaming, all three implants demonstrated increased peak stress and slightly elevated peak displacement; however, PFTBN remained the most stable. Notably, reaming significantly reduced the overall peak stress of the femur. Collectively, PFTBN more effectively reduced the stress and displacement of both the femur and the implant under both reamed and unreamed conditions, with “II” PFBN showing intermediate efficacy. Both novel devices provided superior internal fixation stability compared to PFNA, which may contribute to a reduced risk of postoperative complications.

PFTBN outperforms “II” PFBN and PFNA in load/shear resistance for intertrochanteric fractures with lateral wall injury, regardless of reaming. “II” PFBN also shows superior stability to PFNA. Reaming increases nail-bone contact, mitigating femoral stress concentration and refracture risk. Both PFTBN and “II” PFBN are reliable fixation options with promising clinical utility.

## Full-text entities

- **Diseases:** femoral fractures (MESH:D005264), intertrochanteric fractures (MESH:D006620)

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC12971711/full.md

## Figures

6 figures with captions in the complete paper: https://tomesphere.com/paper/PMC12971711/full.md

## References

30 references — full list in the complete paper: https://tomesphere.com/paper/PMC12971711/full.md

---
Source: https://tomesphere.com/paper/PMC12971711