# Autogenous Costal Cartilage Grafting With Titanium Mesh Fixation for Comminuted Bilateral Zygomatic Arch Fractures: An Autobiographical Case Report

**Authors:** Richard M Cavero, Ines A Camejo, Adisley Triay, Dileisy Jimenez

PMC · DOI: 10.7759/cureus.104857 · Cureus · 2026-03-08

## TL;DR

A 49-year-old man with severe facial trauma from a climbing accident had successful facial reconstruction using cartilage grafts and titanium mesh.

## Contribution

This case report presents a novel reconstructive approach using autogenous costal cartilage and titanium mesh for complex bilateral zygomatic arch fractures.

## Key findings

- The patient showed satisfactory healing and facial symmetry three months post-surgery.
- The use of autogenous costal cartilage and titanium mesh provided structural stability in a complex fracture case.
- The patient reported high satisfaction with the surgical outcome.

## Abstract

Bilateral zygomatic arch fractures are uncommon but may result in significant midfacial deformity and functional impairment, particularly when fractures are comminuted and structural continuity is compromised. This report describes the surgical management of a 49-year-old male who sustained severe facial trauma following a mountain-climbing accident, resulting in comminuted bilateral zygomatic arch fractures and marked midfacial disfigurement. Due to the complexity of the injury and loss of structural support, autogenous costal cartilage grafting combined with titanium mesh fixation was selected for reconstruction.

Under general anesthesia, bilateral preauricular and infraorbital approaches were used to expose the fracture sites. Autogenous costal cartilage was harvested from the left costal cartilage (typically sixth-eighth rib), contoured according to the anatomical requirements of both zygomatic arches, and positioned to restore midfacial contour. Titanium mesh and screws were applied to achieve rigid fixation and maintain structural stability.

Short-term follow-up of three months demonstrated satisfactory healing without complications. Facial symmetry and midfacial projection were successfully restored, and the patient reported high satisfaction with the surgical results. The patient described in this report is also one of the authors, and this dual role is disclosed for ethical transparency. This case highlights autogenous costal cartilage grafting with titanium mesh fixation as a viable reconstructive option in complex bilateral zygomatic arch fractures when conventional reduction and fixation may be insufficient.

## Full-text entities

- **Diseases:** comminution (MESH:D018460), depression (MESH:D003866), facial asymmetry (MESH:D005146), deformity (MESH:D009140), Zygomatic Arch Fractures (MESH:D015051), displaced injuries (MESH:D006617), facial injuries (MESH:D005151), Costal Cartilage (MESH:D002357), midfacial deformity (MESH:C537559), falls (MESH:C537863), edema (MESH:D004487), impaired mastication (MESH:D060825), facial trauma (MESH:D020220), pain (MESH:D010146), fracture (MESH:D050723), arch fractures (MESH:D001015), inflammatory (MESH:D007249), injuries (MESH:D014947)
- **Chemicals:** omeprazole (MESH:D009853), Titanium (MESH:D014025), dexamethasone (MESH:D003907), cephalexin (MESH:D002506), amoxicillin (MESH:D000658), clindamycin (MESH:D002981), ibuprofen (MESH:D007052)
- **Species:** Homo sapiens (human, species) [taxon 9606]

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC12967801/full.md

## Figures

8 figures with captions in the complete paper: https://tomesphere.com/paper/PMC12967801/full.md

## References

8 references — full list in the complete paper: https://tomesphere.com/paper/PMC12967801/full.md

---
Source: https://tomesphere.com/paper/PMC12967801