# Local Diagnostic Reference Levels for Common Nuclear Medicine Procedures for Pediatric in Dubai Health

**Authors:** Entesar Z. Dalah, Najlaa K. Al Mazrouei, Zahra A. Al Ali

PMC · DOI: 10.3390/pediatric18010021 · Pediatric Reports · 2026-02-03

## TL;DR

This study establishes diagnostic reference levels for pediatric nuclear medicine procedures in Dubai to improve patient safety and standardize care.

## Contribution

The paper provides the first pediatric nuclear medicine diagnostic reference levels specific to the Dubai Health sector.

## Key findings

- Significant variation in administered activities was observed across different pediatric nuclear medicine procedures.
- Diagnostic reference levels for the 15–<30 kg weight band include 98.4 MBq for renal dynamic and 155 MBq for tumor/infection scans.
- Systematic protocol revisions and continuous dose monitoring are needed for effective dose optimization.

## Abstract

This study aims to establish diagnostic reference levels (DRLs) for common pediatric nuclear medicine (NM) procedures performed within the Dubai Health sector. The established DRLs will serve as a benchmark for pediatric NM practice, supporting standardized healthcare delivery and guiding ongoing quality improvement and internal audit activities. Patient dose survey data were collected from the solo NM center within the Dubai Health sector. The study included common scintigraphy procedures using gamma cameras and the hybrid positron emission tomography with computed tomography (PET/CT) procedures. Scintigraphy procedures include the dynamic and static renal scans, and ocular eye scans. The hybrid PET/CT procedures entail tumor/infection and neuroendocrine scans. Patient demographics, administered activities, CT doses, and study description were recorded. Both weight bands of <5, 5–<15, 15–<30, 30–<50, and 50–<80 kg, and age bands of <1, 1–<5, 5–<10, and 10–<15 years were considered. Statistical analysis was performed to determine the 25th percentile, median and 75th percentile of the dose distribution. The median value was used to establish the DRLs for the Dubai Health sector. The analyses revealed significant variation in the administered activities across the different pediatric NM procedures. The proposed DRLs for various pediatric NM procedures for the weight band 15–<30 kg are as follows: renal dynamic 98.4 MBq, renal static 96.2 MBq, ocular eyes 18.5 MBq, tumor/infection 155 MBq, and neuroendocrine 80 MBq. This work provides the first pediatric NM DRLs for the Dubai Health sector, offering a key reference for developing the local DRLs for the Emirate of Dubai. The findings indicate that achieving meaningful dose optimization will require systematic revision of existing imaging protocols, with targeted parameter adjustments informed by continuous dose monitoring and benchmarking to enhance patient safety and overall diagnostic quality.

## Full-text entities

- **Diseases:** DRLs (MESH:D053591), infection (MESH:D007239), Meckel's diverticulum (MESH:D008467), tumor (MESH:D009369), NM (MESH:C564596), injury to (MESH:D014947), neuroendocrine tumor (MESH:D018358)
- **Chemicals:** 18F-FDG (MESH:D019788), 99mTc-MAA (-), 68Ga-DOTATOC (MESH:C499142), 99m-technetium (MESH:D013667)
- **Species:** Homo sapiens (human, species) [taxon 9606]

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC12921923/full.md

## Figures

4 figures with captions in the complete paper: https://tomesphere.com/paper/PMC12921923/full.md

## References

25 references — full list in the complete paper: https://tomesphere.com/paper/PMC12921923/full.md

---
Source: https://tomesphere.com/paper/PMC12921923