# A point-of-care assay for genotyping women prior to ovarian stimulation with recombinant or human menopausal gonadotropins in assisted reproduction

**Authors:** Mathilda Nilsson, Ida Hjelmér, Alexandra Prahl, Hannah Nenonen, Yvonne Lundberg Giwercman

PMC · DOI: 10.3389/fendo.2026.1697345 · Frontiers in Endocrinology · 2026-01-28

## TL;DR

This paper introduces a fast and easy genotyping test to help doctors choose the best ovarian stimulation treatment for IVF based on a patient's genetic profile.

## Contribution

A rapid, point-of-care genotyping assay for the FSHR N680S variant using LAMP technology is developed and validated.

## Key findings

- The LAMP assay achieved 91% overall accuracy in genotyping the FSHR N680S variant.
- The test demonstrated 86.8% clinical sensitivity and 100% specificity.
- The assay can be completed in under one hour by trained staff.

## Abstract

Prior to in vitro fertilization (IVF), physicians can choose either recombinant or urine-derived follicle-stimulating hormone (FSH) for ovarian stimulation. The common polymorphism N680S (rs6166) in the follicle-stimulating hormone receptor (FSHR) has been linked to individual variability in ovarian response to FSH stimulation and IVF outcomes, including live birth rates, highlighting its potential value in optimizing stimulation protocols. However, classical genotyping is laborious, often requiring blood as starting material and specialized laboratories for analysis. The aim of the study was to develop a system for rapid and easy-to-use genotyping of the FHSR N680S variant.

The assay constituted an allele-specific peptide nucleic acid-mediated loop-mediated isothermal amplification (AS PNA-mediated LAMP) assay with a colorimetric detection system. The analytical performance was analyzed with naked-eye detection and verified with fluorescence amplification. Clinical validation was assessed on 50 patients visiting an IVF-clinic in whom the variant was confirmed with Sanger sequencing.

Ninety-one out of 100 samples were genotyped correctly, demonstrating 91% overall accuracy. Clinical sensitivity reached 86.8 [95% Cl 76.4-93.8%], while specificity was 100% [95% Cl 89.1-100%]. The test was performed by trained laboratory staff in less than one hour.

The LAMP assay provides a rapid and user-friendly genotyping of the FSHR N680S, which makes it a valuable tool in point-of-care settings, where it may help guide treatment options prior to IVF.

## Linked entities

- **Genes:** FSHR (follicle stimulating hormone receptor) [NCBI Gene 2492]

## Full-text entities

- **Genes:** FSHR (follicle stimulating hormone receptor) [NCBI Gene 2492] {aka FSHR1, FSHRO, LGR1, ODG1}
- **Chemicals:** PNA (MESH:D020135), menopausal gonadotropins (-)
- **Species:** Homo sapiens (human, species) [taxon 9606]
- **Mutations:** N680S

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC12890628/full.md

## Figures

4 figures with captions in the complete paper: https://tomesphere.com/paper/PMC12890628/full.md

## References

35 references — full list in the complete paper: https://tomesphere.com/paper/PMC12890628/full.md

---
Source: https://tomesphere.com/paper/PMC12890628