# Design and performance analysis of a vertically stacked gate-all-around nanosheet FET with embedded nanocavity for biosensing applications

**Authors:** Rudra Lakshmi Prasanna, Srinivasa Rao Karumuri, Vakkalakula Bharath Sreenivasulu, Girija Sravani Kondaveeti

PMC · DOI: 10.1038/s41598-026-35132-1 · Scientific Reports · 2026-01-29

## TL;DR

This paper presents a new biosensor design using a vertically stacked transistor that can detect cancer biomolecules with high sensitivity and faster response times.

## Contribution

A novel vertically stacked gate-all-around nanosheet FET with embedded nanocavity for enhanced biosensing performance is proposed.

## Key findings

- The biosensor achieves a current sensitivity of 3.1 × 10³ and a subthreshold swing of 27.72 mV/dec.
- Sensitivity is primarily influenced by the number of biomolecules rather than their filling position.
- The device shows significantly higher sensitivity compared to existing biosensors.

## Abstract

In this article, we designed and analyzed a Vertically Stacked Gate All Around Dielectric Modulated Nano Sheet Field Effect Transistor (DM-NSFET) based biosensor through TCAD simulations. The DM-NSFET is designed for detection of Cancer biomolecules like SW 620, HEK293, and other biomolecules like DNA, gelatin. This functionality comes out through the modulation of its electrical properties by incorporating cavity all around at two sides of dielectric material (HfO2) under the gate electrode to allow biomolecules. The proposed device contains gate all around to increase the sensitivity of device. The sensitivity variation of biosensors is analyzed in terms of subthreshold swing (SS), Selectivity and response time (τ). Further, the effect of filling positions on sensitivity is examined under different cases, this biosensor sensitivity mainly depends on number of biomolecules filling rather than the specific filling position. The obtained results indicates that the proposed device is reaches its current sensitivity of 3.1 × 103, subthreshold swing (SS) of 27.72 mV/dec. The proposed device exhibits significantly enhanced sensitivity compared to existing biosensors and therefore, this biosensor is highly suitable for diagnosis of Cancer Biomolecule.

## Linked entities

- **Chemicals:** HfO2 (PubChem CID 159422)
- **Diseases:** Cancer (MONDO:0004992)

## Full-text entities

- **Diseases:** Cancer (MESH:D009369)
- **Chemicals:** HfO2 (-)

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC12886953/full.md

## Figures

15 figures with captions in the complete paper: https://tomesphere.com/paper/PMC12886953/full.md

## References

4 references — full list in the complete paper: https://tomesphere.com/paper/PMC12886953/full.md

---
Source: https://tomesphere.com/paper/PMC12886953