# Effect of screw thread type on implant-related complications following femoral neck fracture fixation in non-geriatric adults: a multicenter, retrospective cohort study

**Authors:** Yuquan Bian, Kai Yang, Sen Lin, Shizan He, Dajun Jiang, Weitao Jia

PMC · DOI: 10.3389/fsurg.2025.1745105 · 2026-01-13

## TL;DR

This study compares the use of partially and fully threaded screws in treating femoral neck fractures in non-geriatric adults, finding that screw type affects complication rates depending on fracture severity.

## Contribution

The study provides evidence-based guidance on screw thread type selection for femoral neck fracture fixation based on fracture comminution status.

## Key findings

- Partially threaded screws are associated with lower implant cut-out rates in non-comminuted fractures.
- Fully threaded screws reduce femoral neck shortening and avascular necrosis in comminuted fractures.
- Fracture comminution significantly increases the risk of femoral neck shortening and avascular necrosis.

## Abstract

This study compared implant-related complications after femoral neck fracture fixation using partially vs. fully threaded cannulated screws in non-geriatric patients.

This retrospective cohort study included 1,035 patients with femoral neck fractures aged 18–60 years treated with cannulated screws from 2012 to 2022. Patients were followed until clinical failure—defined as the occurrence of any of the following: implant cut-out, femoral neck shortening, nonunion, or avascular necrosis—or for a minimum of 2 years. Patients were categorized into two groups according to thread type and balanced using propensity score matching. The primary outcome was the clinical failure rate. Subgroup analyses were performed for comminuted vs. non-comminuted fractures.

The overall clinical failure rate was 35.4%, including implant cut-out (1.9%), femoral neck shortening (15.0%), nonunion (9.3%) and avascular necrosis (23.5%); this rate was significantly higher for those with comminuted fractures. After balancing covariates, the partially threaded group demonstrated higher rates of femoral neck shortening (13.7% vs. 6%, p = 0.017) and avascular necrosis (17.9% vs. 9.5%, p = 0.027) than the fully threaded group in the overall cohort. In the non-comminuted subgroup, the partially threaded group was associated with significantly lower rates of implant cut-out (0% vs. 8.7%, p < 0.01) than the fully threaded group. However, in the comminuted fracture subgroup, the fully threaded group exhibited significantly lower incidences of femoral neck shortening (6.6% vs. 22.4%, p < 0.01) and avascular necrosis (10.5% vs. 36.2%, p < 0.01).

Fracture comminution increases the risk of femoral neck shortening and avascular necrosis. In non-comminuted fractures, the use of partially threaded screws should be prioritized. However, in comminuted fractures, using fully threaded screws decreases rates of femoral neck shortening and avascular necrosis. This study provides evidence to guide cannulated screw thread type selection for comminuted fractures and paves the way for future randomized controlled trials.

## Linked entities

- **Diseases:** avascular necrosis (MONDO:0018373)

## Full-text entities

- **Diseases:** Fracture comminution (MESH:D018460), nonunion (MESH:C538144), fracture (MESH:D050723), femoral neck fracture (MESH:D005265), avascular necrosis (MESH:D010020)
- **Species:** Homo sapiens (human, species) [taxon 9606]

## Figures

2 figures with captions in the complete paper: https://tomesphere.com/paper/PMC12835346/full.md

---
Source: https://tomesphere.com/paper/PMC12835346