Blood Component Utilization and Discard Patterns in Telangana, India: A Three-Year Retrospective Study
Jeeth Rai, Nirlipta Kumar Behera, Manoj Kumar Gupta, Prathyusha Vemuri, Balaji Dhanraj Kendre, Heena Dixit, Rahul VC Tiwari, Deepak Agrawal, Seema Gupta

TL;DR
This study examines blood component usage and waste in Telangana, India, finding high red cell efficiency but significant plasma and platelet waste.
Contribution
The study provides empirical data on blood component utilization and discard patterns in Telangana over three years, identifying key areas for improvement.
Findings
Packed red cells had the highest utilization (92.1%) and lowest discard (7.9%).
FFP and PCs had higher discard ratios (16.9% and 17.0%) due to expiry and suboptimal use in oncology and pediatrics.
Expiry-related discards increased from 1,068 units in 2022 to 1,373 units in 2024.
Abstract
Background Blood transfusion services play a central role in emergency and routine clinical care, making the optimal utilization of blood components essential for healthcare efficiency. The present study aimed to evaluate statewide patterns of requisition, utilization, and discard of blood components across licensed blood banks in Telangana over a three-year period, and to identify component-specific and system-level factors contributing to wastage. Methodology This retrospective, observational study analyzed records from 50 licensed blood banks across Telangana between January 2022 and December 2024. Data on requisition, cross-matching, issue, transfusion, return, and discarding of packed red cells (PRCs), fresh frozen plasma (FFP), and platelet concentrates (PCs) were collected using a standardized protocol. Key indicators such as crossmatch-to-transfusion ratio (C/T), transfusion…
Genes, proteins, chemicals, diseases, species, mutations and cell lines named across the full text — each resolved to its canonical identifier and authoritative record.
| Year | Components requisitioned | Components issued | Components transfused | Components discarded | Utilization ratio (%) | Discard ratio (%) |
| 2022 | 18,209 | 16,571 | 14,638 | 1,933 | 88.3% | 11.7% |
| 2023 | 19,142 | 17,316 | 15,267 | 2,049 | 88.2% | 11.8% |
| 2024 | 19,131 | 17,176 | 14,884 | 2,292 | 86.7% | 13.3% |
| Total | 56,482 | 51,063 | 44,789 | 6,274 | 87.7% | 12.3% |
| Component type | Requisitioned | Issued | Transfused | Discarded | Utilization ratio (%) | Discard ratio (%) |
| Packed red blood cells | 28,127 | 26,048 | 24,002 | 2,046 | 92.1% | 7.9% |
| Fresh frozen plasma | 15,764 | 13,721 | 11,409 | 2,312 | 83.1% | 16.9% |
| Platelet concentrates | 12,591 | 11,294 | 9,378 | 1,916 | 83.0% | 17.0% |
| Total | 56,482 | 51,063 | 44,789 | 6,274 | 87.7% | 12.3% |
| Department | Components issued | Components transfused | Utilization ratio (%) |
| Surgery | 14,441 | 13,329 | 92.3 |
| Obstetrics & Gynecology | 9,292 | 8,326 | 89.6 |
| Medicine | 10,192 | 8,989 | 88.2 |
| Oncology | 7,261 | 5,722 | 78.8 |
| Intensive Care Unit | 5,104 | 4,823 | 94.5 |
| Others (Pediatrics, etc.) | 4,772 | 3,608 | 75.6 |
| Total | 51,063 | 44,797 | 87.7 |
| Discard reason | 2022 (n = 1,933) | 2023 (n = 2,049) | 2024 (n = 2,292) | Total (n = 6,274) |
| Expiry | 1,068 (55.3) | 1,194 (58.3) | 1,373 (59.9) | 3,635 (58.0) |
| TTI seropositivity | 445 (23.0) | 470 (22.9) | 492 (21.5) | 1,407 (22.4) |
| Leakage/Breakage | 193 (10.0) | 203 (9.9) | 263 (11.5) | 659 (10.5) |
| Clerical errors | 145 (7.5) | 155 (7.6) | 165 (7.2) | 465 (7.4) |
| Clot formation | 82 (4.2) | 85 (4.1) | 90 (3.9) | 257 (4.1) |
| Total | 1,933 (100) | 2,049 (100) | 2,292 (100) | 6,274 (100) |
| Blood bank code | Units crossmatched (C) | Units transfused (T) | C/T ratio | Transfusion probability (%T) | Transfusion index (TI) |
| BB-01 | 2,410 | 1,986 | 1.21 | 82.4 | 0.82 |
| BB-07 | 1,893 | 1,102 | 1.72 | 58.2 | 0.58 |
| BB-14 | 1,504 | 802 | 1.87 | 53.3 | 0.53 |
| BB-21 | 2,208 | 1,576 | 1.40 | 71.4 | 0.71 |
| BB-29 | 1,601 | 904 | 1.77 | 56.5 | 0.56 |
| BB-37 | 1,946 | 1,365 | 1.42 | 70.1 | 0.70 |
| BB-45 | 1,701 | 1,209 | 1.41 | 71.1 | 0.71 |
| Mean | 1,894.7 | 1,277.7 | 1.50 | 66.1 | 0.70 |
| SD | 327.21 | 408.21 | 0.24 | 10.4 | 0.10 |
Peer Reviews
No public reviews on file for this paper yet. If you reviewed it on a platform where reviews are public (OpenReview, ICLR, NeurIPS, ICML), you can paste yours below so the community can read it here.
Videos
No videos yet. Explain this paper in a talk, walkthrough, or lecture? Add one.
Taxonomy
TopicsBlood transfusion and management · Blood donation and transfusion practices · Trauma, Hemostasis, Coagulopathy, Resuscitation
Introduction
Blood transfusion services form a vital lifeline in modern healthcare, supporting the management of trauma, major surgeries, obstetric emergencies, malignancies, and chronic anemia. With rising demand and persistent shortages, the rational use of blood and its components has become a global priority [1]. In low- and middle-income countries, despite a well-structured national blood policy advocating voluntary donation and component separation, significant gaps persist in clinical practices, leading to precautionary overordering, underutilization of issued units, and high discard ratios [2,3]. These inefficiencies not only escalate costs but also undermine the efforts of voluntary donors and strain an already limited resource.
The shift from whole blood to component therapy has improved therapeutic precision; however, it has introduced new challenges related to shelf life and storage conditions. Packed red blood cells (PRCs) enjoy a longer shelf-life of 35-42 days, whereas platelets remain viable for only five days, and fresh frozen plasma (FFP), although stable for one year when frozen, often faces expiry after thawing if not utilized promptly [4]. Consequently, platelets and plasma consistently record higher waste worldwide, particularly in resource-constrained settings with unpredictable demand and suboptimal inventory management [5].
In India, a previous single-center study reported a discard ratio of 6.95%, largely attributable to expiry, transfusion-transmitted infection (TTI) seropositivity, and clerical errors [6]. However, most audits are institution-specific, of short duration, or limited to whole blood, offering little insight into state-wide or component-specific trends. Telangana, with its rapidly expanding network of over 120 licensed blood banks serving urban, semi-urban, and rural populations, lacks comprehensive data to date on requisition patterns, utilization efficiency, and discarding causes across diverse healthcare tiers.
Therefore, this retrospective study was undertaken to analyze blood component requisition, issue, transfusion, and discard practices across 50 licensed blood banks in Telangana using standardized quality indicators such as crossmatch-to-transfusion ratio (C/T), transfusion probability (%T), and transfusion index (TI), with the aim of generating evidence-based insights to strengthen rational transfusion practices and minimize preventable wastage in the region.
Materials and methods
This retrospective observational study was conducted over a three-month period (May-July 2025). The analysis encompassed data spanning three calendar years (January 1, 2022, to December 31, 2024) collected from 50 licensed blood banks across Telangana, India. The participating blood banks were purposively selected from the state’s 153 licensed facilities (as per Drugs Control Administration, Telangana, January 2025) to ensure representation of all healthcare tiers and geographical regions: tertiary-care teaching and corporate hospitals in urban areas, district and area hospitals in semi-urban locations, and community health centers with standalone blood banks in rural districts. Only centers equipped with component separation facilities and maintaining complete records throughout the study period were included; those exclusively providing whole-blood transfusions or having more than 10% missing data in any year were excluded.
A convenience sampling approach was employed, wherein licensed blood banks that were willing to participate and had complete records for the study period were included. To enhance representativeness and reduce selection bias, purposive stratification was applied to ensure inclusion of blood banks from different healthcare tiers (tertiary-care teaching and corporate hospitals, district hospitals, and rural standalone blood banks) and from diverse geographic regions of Telangana, including urban, semi-urban, and rural areas.
The study protocol was approved by the Institutional Ethics Committee of Index Medical College, Malwanchal University, Indore, Madhya Pradesh, India (IEC Ref: MU/RO/Ph.D/GN/2025/121), which served as the coordinating institution. Additional administrative approval was obtained from the Telangana State Blood Transfusion Council and medical superintendents or directors of individual centers. As the study involved only aggregate, anonymized data without patient or donor identifiers, the requirement for individual consent was waived.
All documented requirements for blood components, such as PRCs, FFP, and platelet concentrate (PC), issued during the study period were included, and records of requisition, cross-matching, issue, transfusion, return, and discard were complete. Whole-blood units, emergency uncross-matched O-negative issues without subsequent transfusion confirmation, autologous or directed donations, and records with ambiguous reasons for discarding were excluded.
Data were extracted using standardized, pre-tested proforma from blood bank registers, issue and transfusion logs, discard registers, and requisition forms. The variables collected included total units requisitioned, cross-matched, issued, transfused, returned unused, and discarded; component type; requesting clinical department; reason for discarding (expiry, TTI seroreactivity, leakage/hemolysis, clotting, broken bag, clerical/labeling error, or others); donor category (voluntary/replacement); and relevant dates. Four trained postgraduate residents performed data collection over four months, with 10% of the records independently verified by the principal investigator. Double-data entry was performed, and discrepancies were resolved by re-examination of the original registers.
Transfused probability (%T) was calculated as follows [7]:
[ \text{Percent unit transfused (%T)} = \frac{\text{Patients transfused}}{\text{Patients cross-matched}} \times 100 % ]
Acceptable T≥30%.
The transfused index (TI) was calculated as follows [7]:
[ \text{Transfusion index (T)} = \frac{\text{Patients transfused}}{\text{Patients cross-matched}} ]
Utilization ratio was calculated as follows [7]:
[ \text{Utilization ratio} = \frac{\text{Units transfused}}{\text{Units issued}} \times 100% ]
Discard ratio was calculated as follows [7]:
[ \text{Discard ratio} = \frac{\text{Units discarded}}{\text{Units issued}} \times 100% ]
The primary outcomes were overall and component-specific utilization and discard ratios, along with the reasons for discarding. Secondary outcomes included C/T ratio [7], %T, and TI across departments and facility types, as well as year-wise trends over the three-year study period. Data were analyzed using SPSS version 23.0 (IBM Corp., Armonk, NY, USA). Descriptive statistics are expressed as frequencies, percentages, and means ± standard deviations. Year-wise comparisons were descriptive; no formal statistical test for temporal trend was applied. Comparisons across blood components and clinical departments were descriptive in nature; no inferential statistical testing was performed for these comparisons.
Results
Table 1 summarizes the yearly utilization and discarding ratio of blood components from 2022 to 2024. The number of requisitioned and issued components shows a steady increase over the years, with the highest requisition in 2023. Although the number of transfusions has also increased, 2024 recorded a slight decline in utilization efficiency, reflected by the lowest utilization ratio of 86.7%. The discard ratio increased to 13.3% in 2024, indicating higher wastage compared to previous years. Overall, across the three years, an average utilization ratio of 87.7% and a discard ratio of 12.3% highlight consistent service efficiency, with a need for improved inventory management to reduce discards.
Table 2 presents the utilization and discard ratio of different blood components. PRC showed the highest efficiency, with a utilization ratio of 92.1% and the lowest discard ratio of 7.9%. In contrast, FFP and PC demonstrated lower utilization ratios and higher discard ratios. These findings indicate that PRCs are used more effectively, whereas FFP and PCs experience greater wastage, likely due to their shorter shelf life and specific storage requirements.
Table 3 shows the department-wise utilization of the blood components. The intensive care unit (ICU) demonstrated the highest utilization ratio (94.5%), followed closely by the surgery department (92.3%), indicating the efficient use of blood units. Obstetrics and gynecology (89.6%) and medicine (88.2%) also showed good utilization. Oncology recorded a moderate rate of 78.8%, while the “Others” category, including pediatrics, had the lowest utilization at 75.6%. Overall, across all departments, the utilization ratio was 87.7%, reflecting the generally effective use of blood components.
Table 4 summarizes the annual reasons for discarding blood components from 2022 to 2024. Expiry remained the most common cause, steadily increasing from 1,068 units in 2022 to 1,373 units in 2024 and contributing to more than half of all discards. TTI seropositivity was the second major reason, followed by leakage or breakage, both of which showed a gradual increase over the years. Clerical errors and clot formation accounted for smaller but consistent proportions of discarded units. Overall, 6,274 components were discarded across three years, indicating the need for improved inventory management, enhanced donor screening, and stricter handling protocols to reduce preventable wastage.
Table 5 presents the operational efficiency indicators for various blood banks. BB-01 showed the highest efficiency, with the lowest C/T ratio (1.21), highest transfusion probability (82.4%), and a strong transfusion index (0.82). Blood banks BB-07, BB-14, and BB-29 demonstrated lower efficiency, as reflected by higher C/T ratios and reduced transfusion probability. BB-21, BB-37, and BB-45 showed moderate to good performance, with balanced utilization indicators. The mean C/T ratio of 1.5 and transfusion probability of 66.1% suggested overall acceptable efficiency across centers, although variability indicated by the standard deviations highlights the need for performance standardization and improved crossmatch-to-transfusion practices. Table 5 presents selected examples to demonstrate variability in performance indicators across blood banks; summary statistics derived from this subset are not intended to represent statewide estimates.
Discussion
This three-year retrospective study involving 50 licensed blood banks in Telangana provides the most comprehensive statewide insight into blood component utilization and wastage patterns in a rapidly developing Indian state. During the study period (2022-2024), approximately 51,063 blood component units were issued, with 87.7% utilization ratio and 12.3% discard ratio. Kulkarni et al. [8] found that a total of 3,280, 1,868, and 486 units of whole blood were collected in 2018, 2019, and 2020, respectively. The observed whole blood discard ratios were 9.48%, 17.23%, and 43% in 2018, 2019, and 2020, respectively, in a tertiary care hospital blood bank in North Karnataka. A progressive increase in the discard ratio from 10.8% in 2022 to 13.3% in 2024 was found in our study despite increasing requirements, signals worsening inventory-pressure mismatch, and calls for urgent system-level corrective measures.
Component-specific analysis reinforces global trends: PRC exhibited the highest utilization (92.1%) and lowest wastage (7.9%), attributable to its longer shelf-life (35-42 days) and more predictable demand. Far et al. [9] determined that a significant proportion (77.9%) of PRCs were rendered unusable owing to expiration, with a reported variability ranging from 1.93% to 30.7%. The rates of wastage for PRC, FFP, and PC were quantified as 5.7 ± 0.7, 1.4 ± 0.4, and 3.2 ± 0.5, respectively, as documented by Amini Kafi-Abad et al. [10] in their study conducted in Iran between the years 2005 and 2015. The principal factors contributing to the wastage of blood components were identified as expiration and protocols surrounding the reservation and return of these components from the operating room.
In contrast, platelets (random donor PC or pooled PC) and FFP recorded utilization ratios of only ~83% and discard ratios exceeding 16%, findings almost identical to large audits from India (platelets 51.8%) [11] and New Hampshire (plasma 43% to 66%) [12]. The short shelf life of platelets (five days) and narrow post-thaw window for FFP (24 hours at 4°C) make them highly vulnerable to outdating in settings with fluctuating emergency demand and limited real-time inter-facility transfer mechanisms, a challenge repeatedly documented in low- and middle-income countries [1].
The predominant reason for discarding across all years was expiry, followed by TTI seroreactivity. The rising absolute number of expiry-related discards despite increasing collections reflects overstockpiling driven by fear of shortages, a behavioral pattern well-described in transfusion medicine literature as “just-in-case” ordering [13]. Suresh et al. [14] reported that a 49% discard ratio was due to TTI, suggesting scope for further improvement in donor questionnaire sensitivity, pre-donation counseling, and adoption of pathogen reduction technologies where feasible.
Department-wise utilization data offers actionable insights. ICUs and surgical departments achieved near-optimal efficiency, likely reflecting protocol-driven transfusion triggers and bedside decision making by senior clinicians. Conversely, oncology and miscellaneous (including pediatric) departments exhibited significantly lower utilization, consistent with reports of prophylactic platelet transfusions at higher thresholds and overuse of FFP in hypoalbuminemia or liver disease without coagulopathy. Similar findings have been reported in previous studies [15,16]. These practices contravene international patient blood management (PBM) guidelines and contribute disproportionately to platelet and plasma wastage [17].
The mean C/T ratio of 1.5, %T of 66.1%, and TI of 0.82 are considerably better than earlier Indian studies reporting C/T ratios of 1-2.3 [18,19] and approach the benchmarks recommended by the British Committee for Standards in Haematology (C/T ≤2.0, %T ≥50%) [20]. However, the wide inter-facility variation (C/T ranging from 1.21 to >3.0) highlights the unequal adoption of maximum surgical blood ordering schedules, type-and-screen policies, and electronic crossmatch systems. Centers achieving C/T ratios close to 1.0, such as tertiary teaching or corporate hospitals with 24×7 specialist cover and robust PBM programs.
Clinical and policy implications
The 12-13% discard ratio corresponds to approximately 6,274 wasted components over three years, underscoring the substantial operational and potential economic impact of blood component wastage at the system level. More importantly, this undermines public trust in voluntary donations. Implementing statewide real-time inventory dashboards, first-in-first-out (FIFO) strict enforcement, daily platelet/FFP pooling and redistribution networks, and mandatory prospective audit of all FFP and prophylactic platelet requests could reduce wastage. Adoption of single-unit PRC policies in stable anemia, restrictive thresholds (hemoglobin <7-8 g/dL), and viscoelastic testing in place of conventional coagulation screens would further rationalize their use without compromising outcomes [21].
Limitations
The study relied on retrospective register-based data; underreporting of returned or discarded units cannot be ruled out. Emergency O-negative uncross-matched issues and whole-blood transfusions were excluded, potentially underestimating the total wastage in rural facilities. Detailed clinical indications and patient outcome data were not captured, limiting the correlation with inappropriate use. Finally, although centers were purposively selected for representation, participation was restricted to those with component separation facilities and complete records, introducing a degree of selection bias toward better-resourced blood banks.
Conclusions
This multicenter study revealed that Telangana’s blood transfusion services achieved high red cell utilization and an acceptable mean C/T ratio; however, the overall component wastage reached 12.3%, driven predominantly by expiry of platelets and FFP. The rising discard trend over three years, despite increasing collections, persistent over-ordering, and inadequate redistribution mechanisms. Targeted implementation of statewide real-time inventory sharing, strict FIFO protocols, restrictive transfusion thresholds, and robust PBM programs can substantially reduce preventable waste, enhance resource efficiency, and strengthen public trust in voluntary blood donation across the region.
The reference list from the paper itself. Each links out to its DOI / PubMed record.
- 1The global need and availability of blood products: a modelling study Lancet Haematol Roberts N James S Delaney M Fitzmaurice C 0156201910.1016/S 2352-3026(19)30200-531631023 · doi ↗ · pubmed ↗
- 2Problems and approaches for blood transfusion in the developing countries Hematol Oncol Clin North Am Roberts DJ Field S Delaney M Bates I 4774953020162704096610.1016/j.hoc.2015.11.011 · doi ↗ · pubmed ↗
- 3Status of hospital-based blood transfusion services in low-income and middle-income countries: a cross-sectional international survey BMJ Open Barnes LS Stanley J Bloch EM 012202210.1136/bmjopen-2021-055017 PMC 885276235168978 · doi ↗ · pubmed ↗
- 4The use of whole blood transfusion in trauma Curr Anesthesiol Rep Hanna M Knittel J Gillihan J 2342391220223506901710.1007/s 40140-021-00514-w PMC 8761832 · doi ↗ · pubmed ↗
- 5Platelet inventory management with demand and supply uncertainty and variable pricing considerations Transfus Apher Sci Mallari CB Alegre MC Chuang KG Gallardo GK Sy AW San Juan JL 1037706220233751794110.1016/j.transci.2023.103770 · doi ↗ · pubmed ↗
- 6Analysis on discard of blood and its products with suggested possible strategies to reduce its occurrence in a blood bank of tertiary care hospital in Western India Glob J Transfus Med Kanani A Vachhani J Dholakiya S Upadhyay S 13013622017
- 7The maximum surgical blood order schedule and surgical blood use in the United States Transfusion Friedman BA Oberman HA Chadwick AR Kingdon KI 38038716197695173710.1046/j.1537-2995.1976.16476247063.x · doi ↗ · pubmed ↗
- 8The rationale for discarding blood and its components in a tertiary care hospital blood bank in North Karnataka Cureus Kulkarni KR Kulkarni P Jamkhandi U 014202210.7759/cureus.31112 PMC 972035036479408 · doi ↗ · pubmed ↗