# Evaluation of occupational exposure to airborne quartz in the cutting and grinding of ceramic tiles

**Authors:** Francesca Borghi, Francesca Graziosi, Silvia Contessi, David C Christiani, Francesco Decataldo, Deborah Glass, Francesco S Violante

PMC · DOI: 10.1093/annweh/wxaf044 · Annals of Work Exposures and Health · 2025-09-16

## TL;DR

This study measures high silica dust exposure during ceramic tile cutting, showing it can exceed safety limits even with short work periods.

## Contribution

The study evaluates real-world silica exposure during tile cutting and calculates how quickly safety limits are exceeded.

## Key findings

- Silica exposure during tile cutting reached up to 240.9 µg/m³, exceeding European safety limits.
- Even short work periods can lead to silica exposure exceeding 8-hour time-weighted average limits.
- Respiratory protection can reduce exposure by factors of 10 or 20.

## Abstract

Crystalline silica was categorized by the International Agency for Research on Cancer as a known human carcinogen. Activities related to the processing of ceramic tiles, releasing crystalline silica, may vary considerably in terms of hours worked per day and days worked per week. This variability could be particularly high for craftsmen who process ceramic materials directly on-site during installation. The aim of this study is to measure the likely exposure to respirable crystalline silica (RCS) during ceramic tiles installation, evaluating the exposure to RCS of workers processing these tiles. Exposure assessments to RCS were conducted via both fixed-site and personal sampling for 2 working hours. The measured concentrations were calculated as 8-h time-weighted average (TWA) exposures, assuming no further RCS exposure in the time period. The permitted exposure time, not to exceed the occupational exposure limit (OEL) value, was then calculated also considering the assigned protection factor of selected respiratory protective equipment. The results of this study, considered as a worst-case simulation, show that, during the processing of ceramic tiles releasing RCS, the worker exposure can be very high (up to 240.9 µg/m3), exceedance of several OELs, including the European OEL of 100 µg/m³.

Even working for a few hours a day, the RCS 8-h TWA OEL is likely to be exceeded. Inhaled exposure concentrations can be reduced by using appropriate respiratory protection, by a factor equal to 10 or 20. The assumption of this work was that (i) the cutting/grinding times are not always necessarily equal to 2 h and that (ii) these processes are not characterized by pre-established and continuous processing times. For these reasons, it is important to carefully evaluate the duration of exposure to RCS during the various tasks/activities performed, as these may vary depending on different factors.

## Linked entities

- **Chemicals:** crystalline silica (PubChem CID 24261)

## Full-text entities

- **Diseases:** Cancer (MESH:D009369)
- **Chemicals:** Crystalline silica (-), RCS (MESH:D011791)
- **Species:** Homo sapiens (human, species) [taxon 9606]

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC12822604/full.md

## Figures

1 figure with captions in the complete paper: https://tomesphere.com/paper/PMC12822604/full.md

## References

35 references — full list in the complete paper: https://tomesphere.com/paper/PMC12822604/full.md

---
Source: https://tomesphere.com/paper/PMC12822604