# Robust filtering of thin‐slice reconstructions improves lacunar stroke detection in CT perfusion imaging

**Authors:** Joris Vromans, Edwin Bennink, Jan Willem Dankbaar, Birgitta K. Velthuis, Hugo W. A. M. de Jong

PMC · DOI: 10.1002/mp.70271 · Medical Physics · 2026-01-14

## TL;DR

Using thin-slice CT perfusion imaging with a specific noise filter improves detection of small lacunar strokes.

## Contribution

Temporal-average guided filtering significantly enhances detection of lacunar strokes in thin-slice CTP imaging.

## Key findings

- Temporal-average guided filtering achieved the highest F1-scores for thin-slice reconstructions.
- Thin-slice temporal-average guided filtering improved contrast-to-noise ratio and observer confidence.
- Sensitivity for detecting 7 mm and 10 mm lacunar infarcts reached 73% and 75%, respectively.

## Abstract

The detection of lacunar strokes in CT perfusion (CTP) imaging may be improved by reducing the reconstructed CTP slice thickness. However, this increases noise, necessitating the use of robust noise filters.

To Investigate the impact of slice thickness and three state‐of‐the‐art noise filters on the detection of lacunar strokes of varying sizes.

Artificial spherical lacunar infarcts (diameter: 5, 7, and 10 mm) were added to 40 thin slice CTP acquisitions. The performance of time‐intensity profile guided filtering, temporal‐average guided filtering, and a U‐Net based filter were compared based on infarct detectability in cerebral blood volume maps of thick‐ (4.9 mm) and thin‐slice (0.7 mm) reconstructions. One observer evaluated the maps for each combination of filter and slice thickness. A second observer repeated the evaluation for the two best performing combinations. F1‐score, contrast‐to‐noise ratio, and observer confidence were calculated for every combination of filter, slice thickness, and observer.

The highest F1‐scores were achieved with the temporal‐average guided filter (thin slices: 0.70, thick slices: 0.49). The other filters did not exceed an F1‐score of 0.36 on either thin‐ or thick slices. Thin‐slice temporal‐average guided filtering also achieved the highest contrast‐to‐noise ratio and observer confidence, which resulted in a sensitivity of 10% for 5 mm, 73% for 7 mm, and 75% for 10 mm diameter lacunar infarcts.

This study demonstrates that robust noise filtering, particularly temporal‐average guided filtering, enables improved detection of lacunar strokes (≥7 mm) in CTP imaging using thin‐slice reconstructions.

## Full-text entities

- **Diseases:** lacunar infarcts (MESH:D059409), infarct (MESH:D007238)

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC12802825/full.md

## Figures

10 figures with captions in the complete paper: https://tomesphere.com/paper/PMC12802825/full.md

## References

20 references — full list in the complete paper: https://tomesphere.com/paper/PMC12802825/full.md

---
Source: https://tomesphere.com/paper/PMC12802825