# Validity and Reliability of Force Insoles to Measure Center of Pressure During Return-to-Sport Testing

**Authors:** Delaney McNeese, Charles Eisner, Rachel Todd, Brian Noehren, Meredith K. Owen

PMC · DOI: 10.3390/s26010066 · Sensors (Basel, Switzerland) · 2025-12-22

## TL;DR

This study evaluates how well force insoles can measure pressure during jump tests, finding them reliable for some but not all measurements.

## Contribution

The study provides new evidence on the validity and reliability of force insoles for measuring biomechanical variables during return-to-sport testing.

## Key findings

- Force insoles are valid for measuring vertical ground reaction force and anterior-posterior center of pressure.
- They are not valid for medial-lateral center of pressure measurements.
- Force insoles show good reliability for most tested jump types.

## Abstract

Center of pressure is a valuable biomechanical variable, predicting joint loading contributions during movement and giving insight into compensatory patterns. The purpose of this study was to assess the validity and reliability of force insoles in calculating vertical ground reaction force and center of pressure during return-to-sport jump testing. Ten healthy individuals performed double- and single-leg vertical and horizontal jumps on an instrumented treadmill while wearing instrumented force insoles. Vertical ground reaction force and anterior–posterior and medial–lateral center of pressure were collected at peak vertical ground reaction force from both devices. Repeat testing occurred 7 ± 5 days following the initial session. Force insoles were valid for measuring vertical ground reaction force (mean absolute error (MAE): 4.34 N/kg) and anterior–posterior center of pressure (MAE: 10% foot length) but were not valid for medial–lateral center of pressure (MAE: 50% foot width). During double-leg vertical, single-leg vertical, double-leg horizontal, and single-leg horizontal jumps, force insoles demonstrated good reliability for measurements of vertical ground reaction force (ICC: 0.89, 0.75, 0.89, and 0.91), anterior–posterior center of pressure (ICC: 0.88, 0.89, 0.94, and 0.97), and medial–lateral center of pressure (ICC: 0.72, 0.09, 0.82, and 0.73). Force insoles are a valid and reliable alternative to evaluating vertical ground reaction force and anterior–posterior center of pressure during return-to-sport jump testing.

## Full-text entities

- **Genes:** CARD16 (caspase recruitment domain family member 16) [NCBI Gene 114769] {aka COP, COP1, LLID-114769, PSEUDO-ICE}
- **Diseases:** orthopedic injuries (MESH:D009140), lower extremity injury (MESH:D010291), ACLR (MESH:D000070598), injury to (MESH:D014947)
- **Species:** Homo sapiens (human, species) [taxon 9606]

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC12787798/full.md

## Figures

7 figures with captions in the complete paper: https://tomesphere.com/paper/PMC12787798/full.md

## References

19 references — full list in the complete paper: https://tomesphere.com/paper/PMC12787798/full.md

---
Source: https://tomesphere.com/paper/PMC12787798