## TL;DR

A new rapid HIV test (POCT) was tested in China and showed high accuracy and faster results compared to traditional lab tests, helping diagnose early HIV infections more efficiently.

## Contribution

The study is the first real-world evaluation of POCT for acute HIV-1 diagnosis in China, demonstrating its clinical utility and rapid turnaround.

## Key findings

- POCT showed 98.87% sensitivity and 100% specificity for diagnosing acute HIV-1 infection.
- POCT reduced the median time from screening to result reporting by half compared to lab-based testing.
- 94.64% of POCT and lab viral load measurements were within agreement limits, with strong quantitative correlation.

## Abstract

Timely diagnosis of acute HIV infection (AHI) is critical for curbing transmission. However, the diagnostic window prior to antibody development limits the utility of conventional serological assays. Conventional laboratory-based nucleic acid testing (LABT) is often hindered by operational complexity and long turnaround times. Point-of-care nucleic acid testing (POCT) provides a rapid alternative.

This multicenter cross-sectional study enrolled 1,829 adults from 13 cities in Jiangsu Province and Kunming, Yunnan Province, who had reactive screening results but negative or indeterminate Western blot outcomes. The diagnostic accuracy, quantitative correlation, and agreement of the POCT (Xpert® HIV-1 Viral Load point-of-care test) were compared with LABT using the Roche COBAS TaqMan v2.0 or Abbott RealTime HIV-1 assays, with follow-up seroconversion serving as the reference standard. Turnaround time from initial screening to NAT result reporting was compared using Kaplan–Meier analysis. Laboratory staff perceptions of POCT usability were evaluated via questionnaire.

Using follow-up seroconversion as a reference, POCT demonstrated a sensitivity of 98.87% and specificity of 100.00%, with almost perfect agreement with LABT (99.76%, Cohen’s κ = 0.994). Quantitative viral load results exhibited strong correlation between POCT and LABT (r = 0.89), with 94.64% of paired measurements falling within the limits of agreement. POCT significantly reduced the median time from initial screening to result reporting compared to LABT (7 vs. 14 days, p < 0.001) and increased the likelihood of results being returned within 7 days (Hazard Ratio = 2.29, p < 0.001). Most laboratory personnel reported ease of use (30/33, 90.9%) and a preference for the POCT workflow (21/33, 63.6%).

The Xpert HIV-1 POCT provides a highly accurate and rapid alternative to LABT for diagnosing AHI in China. Its implementation can dramatically shorten diagnostic delays, potentially reducing loss to follow-up and onward transmission, thus offering significant value within the national HIV diagnostic framework.

## Full-text entities

- **Diseases:** AHI (MESH:D015658), seroconversion (MESH:D006679)
- **Chemicals:** Xpert (-)
- **Species:** Human immunodeficiency virus 1 (no rank) [taxon 11676]

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC12757961/full.md

## Figures

5 figures with captions in the complete paper: https://tomesphere.com/paper/PMC12757961/full.md

## References

33 references — full list in the complete paper: https://tomesphere.com/paper/PMC12757961/full.md

---
Source: https://tomesphere.com/paper/PMC12757961