# Potential impact of [18F]-FACBC PET in radiotherapy target definition of glioma

**Authors:** Benedikte Emilie Vindstad, Tora Skeidsvoll Solheim, Josefine Ståhl-Kornerup, Ole Skeidsvoll Solheim, Erik Magnus Berntsen, Lars Kjelsberg Pedersen, Anna Maria Karlberg, Live Eikenes

PMC · DOI: 10.1186/s13014-025-02752-2 · Radiation Oncology (London, England) · 2025-11-21

## TL;DR

This study compares [18F]-FACBC PET and MRI for defining radiation therapy targets in glioma patients, finding that PET may help reduce treatment volumes in certain cases.

## Contribution

The study evaluates the impact of [18F]-FACBC PET on radiotherapy planning for gliomas, particularly in non-enhancing tumor regions.

## Key findings

- PET-based GTVs were significantly smaller than MR GTVs when FLAIR hyperintensity was included.
- PET showed high concordance with MR volumes for CTVs based on contrast-enhanced T1 sequences.
- PET underestimates tumor extension in non-enhancing glioma regions, suggesting lower sensitivity to low-grade tissue.

## Abstract

The aim of the study was to compare [18F]-FACBC positron emission tomography (PET)-based radiotherapy (RT) volumes to magnetic resonance (MR)-based volumes and investigate the potential impact of including [18F]-FACBC PET in RT treatment planning for gliomas.

MR- and PET-defined gross tumor volumes (GTVs) were independently contoured on pre-operative [18F]-FACBC PET/MR images in 24 patients with primary or recurrent low- or high-grade glioma. MR GTVs were defined from regions of contrast-enhancement on T1-weighted (ce-T1) sequences. For non-enhancing tumors or non-enhancing tumor components, regions of FLAIR hyperintensity were also included. PET-based GTVs were delineated using a tumor-to-background ratio (TBR) threshold of 2. GTVs were expanded by an isotropic margin to form clinical target volumes (CTVs). Volumetric analysis was performed using size comparisons, Dice coefficients (DC), overlap coefficients (OC) and Hausdorff distances (HD).

PET GTVs were overall significantly smaller than MR GTVs, with median values of 14.8 ccm (6.5–26.7 ccm) and 28.5 ccm (17.2–62.7 ccm), respectively (p = 0.011). No significant volume difference was found between PET and MR volumes when MR volumes were based on ce-T1 only, but PET-based GTVs and CTVs were significantly smaller than MR-based GTVs and CTVs when the latter included FLAIR hyperintensity (p < 0.01). Similarity metrics showed a high degree of concordance between PET and MR volumes in cases where MR volumes were based on ce-T1 only, particularly for CTVs (DC: 0.88 (0.82–0.94), OC: 0.98 (0.96–0.99), HD: 0.86 cm (0.7–1.4 cm)). In comparison, for cases including FLAIR hyperintensity, MR CTVs had a high overlap with PET CTVs (OC: 0.99 (0.96–0.99)), but otherwise significantly lower degree of concordance (DC: 0.66 (0.46–0.81), p < 0.01, HD: 2.65 cm (2.22–3.85 cm), p < 0.001).

[18F]-FACBC PET underestimates tumor extension compared to FLAIR in contrast negative tumors and tumors containing non-enhancing components, indicating reduced sensitivity to low-grade tumor tissue and microscopic tumor infiltration. Inclusion of [18F]-FACBC PET as supplement to MR in RT planning for glioma could however help identify regions of highly malignant tumor, to facilitate target volume reduction and dose escalation strategies.

## Linked entities

- **Chemicals:** [18F]-FACBC (PubChem CID 450601)
- **Diseases:** glioma (MONDO:0021042)

## Full-text entities

- **Diseases:** glioma (MESH:D005910)
- **Chemicals:** [18F]-FACBC (MESH:C117460)

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC12639995/full.md

## Figures

6 figures with captions in the complete paper: https://tomesphere.com/paper/PMC12639995/full.md

## References

4 references — full list in the complete paper: https://tomesphere.com/paper/PMC12639995/full.md

---
Source: https://tomesphere.com/paper/PMC12639995