# A composite index for predicting improvement of mitral regurgitation in patients with multivalvular heart disease after transcatheter aortic valve replacement

**Authors:** Zhi-Cheng Xiao, Gui-Bin Zheng, Tian-Xiang Geng, Zhong-Fei Lu, Zhen Wang, Lei Zheng, Meng-Meng Ren, Fa-Xin Ren

PMC · DOI: 10.3389/fcvm.2025.1679115 · Frontiers in Cardiovascular Medicine · 2025-11-03

## TL;DR

This study develops a composite index to predict whether mitral regurgitation improves after a heart valve procedure called TAVR.

## Contribution

A novel composite index is introduced to predict mitral regurgitation improvement after TAVR with high accuracy.

## Key findings

- Persistent atrial fibrillation and eccentric MR are negative predictors of MR improvement after TAVR.
- Greater interventricular septal thickness is a positive predictor of MR improvement.
- The composite index has excellent predictive performance with an area under the ROC curve of 0.909.

## Abstract

Transcatheter aortic valve replacement (TAVR) has become a standard treatment for severe aortic stenosis (AS). Concomitant mitral regurgitation (MR) is observed in approximately 19%–29% of these patients. Although MR frequently improves after TAVR, persistent MR is associated with worse clinical outcomes, highlighting the need for reliable predictors of MR persistence.

We conducted a single-center, retrospective study that included 53 patients with severe AS and moderate-to-severe MR who underwent TAVR between 2017 and 2024. The primary outcome was MR improvement, defined as a reduction of at least one grade at the 1-year follow-up. To identify independent predictors, we performed multivariable logistic regression analysis.

At 1-year follow-up, MR improvement was observed in 67.9% of patients. Multivariable analysis identified persistent atrial fibrillation [odds ratio (OR): 0.099, 95% CI: 0.017–0.575; P = 0.01] and eccentric MR (OR: 0.066, 95% CI: 0.012–0.370; P = 0.002) as independent negative predictors of improvement. Conversely, greater interventricular septal thickness (OR: 1.825, 95% CI: 1.075–3.099; P = 0.026) was a positive predictor. A composite predictive index integrating these three variables demonstrated excellent discriminative ability, with an area under the receiver operating characteristic curve of 0.909.

This study identifies persistent atrial fibrillation, eccentric MR, and interventricular septal thickness as key independent predictors of MR improvement after TAVR. The derived composite index, with its outstanding predictive performance, provides a novel tool to aid in patient selection and prognostic assessment.

## Linked entities

- **Diseases:** aortic stenosis (MONDO:0042981), atrial fibrillation (MONDO:0004981)

## Full-text entities

- **Diseases:** multivalvular heart disease (MESH:D006331), AS (MESH:D001024), MR (MESH:D008944), atrial fibrillation (MESH:D001281)
- **Species:** Homo sapiens (human, species) [taxon 9606]

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC12620972/full.md

## Figures

2 figures with captions in the complete paper: https://tomesphere.com/paper/PMC12620972/full.md

## References

26 references — full list in the complete paper: https://tomesphere.com/paper/PMC12620972/full.md

---
Source: https://tomesphere.com/paper/PMC12620972