# Proton boron capture therapy: microdosimetry and treatment planning study with boron

**Authors:** Seung Hoon Yoo, Ilya Sedliarou, Jennifer A. MacDiarmid, Himanshu Brahmbhatt, Soorim Han, Kum Bae Kim, Linh T. Tran, Anatoly B. Rosenfeld, Eun Ho Kim, Yen Hwa Lin, Wei Sing Tan, Ying Ying Cheah, Ru Xin Wong, Wen Shen Looi, Shaun Ho, Kwek Boon Han, Paul Yeo, SK Djeng

PMC · DOI: 10.3389/fonc.2025.1615241 · Frontiers in Oncology · 2025-10-17

## TL;DR

This study explores how adding boron to proton therapy can improve radiation effectiveness by increasing microdosimetric lineal energy and enhancing dose uniformity.

## Contribution

The study provides new microdosimetric and treatment planning insights into proton-boron capture therapy under FLASH and conventional delivery.

## Key findings

- At 190 MeV, boron increased lineal energy at the Bragg peak but not at entrance depth.
- Localized boron improved dose uniformity and reduced RBE model discrepancies under FLASH conditions.
- PBCT shows potential to enhance biological effectiveness without macroscopic dose changes.

## Abstract

Proton-boron capture therapy (PBCT) has been proposed as a method to enhance the biological effectiveness of proton therapy through the p + 11B → 3α nuclear reaction. The resulting alpha particles may increase local radiation quality, but the dosimetric and microdosimetric consequences remain uncertain.

Lineal energy distributions were measured using a Silicon-On-Insulator (SOI) microdosimeter under 70 MeV and 190 MeV monoenergetic proton beams delivered with pencil beam scanning. Dose-averaged lineal energy (
yD¯
) values were derived from oscilloscope signals calibrated against Geant4 Monte Carlo simulations. Measurements were performed at both entrance and Bragg peak depths, with and without boronophenylalanine (BPA) delivered via EnGeneIC Dream Vector (EDV™). In parallel, a treatment planning study was conducted in Eclipse TPS to assess the impact of localized high-density boron regions on dose distributions under conventional and FLASH-simulated delivery, using both fixed and variable RBE models.

For 70 MeV protons, no significant difference in 
yD¯
 was observed between boron-loaded and control conditions. At 190 MeV, a reproducible increase in 
yD¯
 was detected at the Bragg peak in the presence of boron (p < 0.01), while no effect was observed at the entrance depth. Treatment planning simulations showed that localized boron density improved dose uniformity within the clinical target volume and reduced discrepancies between fixed and variable RBE dose distributions under FLASH conditions.

These findings indicate that PBCT can induce detectable increases in microdosimetric lineal energy under high-energy proton beams, even in the absence of macroscopic dose enhancement. The treatment planning results further highlight the potential of boron-enhanced LET modulation in conjunction with FLASH delivery. Together, the study supports continued investigation of PBCT as a strategy to optimize biological effectiveness in proton therapy, with future work focusing on realistic boron distribution models and integration of dose-rate effects.

## Linked entities

- **Chemicals:** boronophenylalanine (PubChem CID 53503), BPA (PubChem CID 6623)

## Full-text entities

- **Chemicals:** boron (MESH:D001895), FLASH (-), BPA (MESH:C033685)

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC12589801/full.md

## Figures

8 figures with captions in the complete paper: https://tomesphere.com/paper/PMC12589801/full.md

## References

24 references — full list in the complete paper: https://tomesphere.com/paper/PMC12589801/full.md

---
Source: https://tomesphere.com/paper/PMC12589801