# Neural network enabled wide field-of-view imaging with hyperbolic metalenses

**Authors:** Joel Yeo, Deepak K. Sharma, Saurabh Srivastava, Aihong Huang, Emmanuel Lassalle, Egor Khaidarov, Keng Heng Lai, Yuan Hsing Fu, N. Duane Loh, Arseniy I. Kuznetsov, Ramon Paniagua-Dominguez

PMC · DOI: 10.1515/nanoph-2025-0354 · Nanophotonics · 2025-09-18

## TL;DR

Researchers used a neural network to correct imaging distortions in hyperbolic metalenses, enabling high-quality wide-angle imaging.

## Contribution

A Restormer neural network was successfully trained on simulated data to correct off-axis aberrations in hyperbolic metalenses.

## Key findings

- Restormer neural network corrected severe off-axis aberrations in hyperbolic metalenses.
- High-quality imaging over a 54° field-of-view was achieved experimentally.
- Simulated datasets enabled reference-free training without experimental data collection.

## Abstract

The ultrathin form factor of metalenses makes them highly appealing for novel sensing and imaging applications. Amongst the various phase profiles, the hyperbolic metalens stands out for being free from spherical aberrations and having one of the highest focusing efficiencies to date. For imaging, however, hyperbolic metalenses present significant off-axis aberrations, severely restricting the achievable field-of-view (FOV). Extending the FOV of hyperbolic metalenses is thus feasible only if these aberrations can be corrected. Here, we demonstrate that a Restormer neural network can be used to correct these severe off-axis aberrations, enabling wide FOV imaging with a hyperbolic metalens camera. Importantly, we demonstrate the feasibility of training the Restormer network purely on simulated datasets of spatially-varying blurred images generated by the eigen-point-spread function (eigenPSF) method, eliminating the need for time-intensive experimental data collection. This reference-free training ensures that Restormer learns solely to correct optical aberrations, resulting in reconstructions that are faithful to the original scene. Using this method, we show that a hyperbolic metalens camera can be used to obtain high-quality imaging over a wide FOV of 54° in experimentally captured scenes under diverse lighting conditions.

## Full-text entities

- **Genes:** CHKA (choline kinase alpha) [NCBI Gene 1119] {aka CHK, CK, CKI, EK, NEDMIMS}
- **Diseases:** coma (MESH:D003128)
- **Chemicals:** ArF (MESH:C047730), metalens (-), Si (MESH:D012825), SiO2 (MESH:D012822)

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC12588562/full.md

## Figures

6 figures with captions in the complete paper: https://tomesphere.com/paper/PMC12588562/full.md

## References

42 references — full list in the complete paper: https://tomesphere.com/paper/PMC12588562/full.md

---
Source: https://tomesphere.com/paper/PMC12588562