Relativistic Limits on the Discretization and Temporal Resolution of a Quantum Clock
Tommaso Favalli

TL;DR
The paper explores how relativity affects the precision and resolution of a quantum clock's time measurements.
Contribution
The paper introduces relativistic limits on quantum clock discretization and temporal resolution using POVMs.
Findings
A limit on time eigenvalue discretization is found when the Hamiltonian has an equally spaced spectrum.
Increasing time states reduces the bound on minimum time quanta and allows treating clock values as continuous.
A temporal resolution limit arises when using the clock in a relativistic spacetime measurement framework.
Abstract
We provide a brief discussion regarding relativistic limits on the discretization and temporal resolution of time values in a quantum clock. Our clock is characterized by a time observable chosen to be the complement of a bounded and discrete Hamiltonian that can have an equally spaced or a generic spectrum. In the first case, the time observable can be described by a Hermitian operator, and we find a limit in the discretization for the time eigenvalues. Nevertheless, in both cases, the time observable can be described by a POVM, and, by increasing the number of time states, we show how the bound on the minimum time quantum can be reduced and identify the conditions under which the clock values can be treated as continuous. Finally, we find a limit for the temporal resolution of our time observable when the clock is used (together with light signals) in a relativistic framework for the…
Genes, proteins, chemicals, diseases, species, mutations and cell lines named across the full text — each resolved to its canonical identifier and authoritative record.
Peer Reviews
No public reviews on file for this paper yet. If you reviewed it on a platform where reviews are public (OpenReview, ICLR, NeurIPS, ICML), you can paste yours below so the community can read it here.
Videos
No videos yet. Explain this paper in a talk, walkthrough, or lecture? Add one.
Taxonomy
TopicsAdvanced Frequency and Time Standards · Quantum Mechanics and Applications · Time Series Analysis and Forecasting
1. Introduction
It is well known that fundamental limits emerge in the precision with which we can measure space and time when quantum mechanics and the theory of relativity are considered together [1,2,3,4,5] (see also [6,7,8]). Our purpose in this work is to study the relativistic limits in the discretization and temporal resolution of time values in a quantum clock. A good definition of a clock can be found in the work by Peres [9]: “A clock is a dynamical system which passes through a succession of states at constant time intervals”. Our quantum clock is described by a quantum time observable chosen to be the complement of a bounded and discrete Hamiltonian that can have both an equally spaced and a generic spectrum. Only in the case of an equally spaced energy spectrum can the time observable be described by a Hermitian operator, while, in general, it will be described by a POVM. This type of observable was introduced by Pegg in [10] (see also [11,12,13,14,15]). It generalizes the quantum clock proposed by Salecker and Wigner (SW) in [16,17], where the authors used clocks and light signals in order to measure distances between spacetime events.
Pegg’s clock is, for example, widely used as a time observable in the Page and Wootters quantum time formalism [18,19] (see also [20,21,22,23,24,25,26,27,28,29,30,31,32,33,34] and references therein). However, we do not adopt this framework here, and we treat our time states (to be introduced) as evolving in an external time parameter, which is standard in quantum mechanics. We will return to the Page and Wootters approach in the Conclusions.
As we will see in the following, Pegg’s observable can exhibit both discrete and continuous time values, and we therefore ask whether there is a fundamental limit in the spacing between discrete time values of a clock and whether time values can be safely considered as continuous. Finally, although the time values may be continuous, we ask what is the minimum resolvable interval between them when the clock operates within the relativistic SW framework—that is, the temporal resolution (in what follows, we will refer to also as temporal accuracy). Note that, throughout the text, we use time values or clock values to refer to the values of the clock observable and not to the external time parameter.
We perform our investigation by first considering a clock with equally spaced energy levels in Section 2; then, we generalize the discussion to a clock with a generic spectrum in Section 3. We emphasize that, since any realistic clock is a system with a finite size, the introduction of unbounded Hamiltonians with continuous spectra would not be possible. This is the reason that we choose to focus on bounded and discrete Hamiltonians in describing our clock, also considering that this may encourage experimental applications.
2. Clock with Equally Spaced Energy Spectrum
2.1. The Quantum Clock
We introduce the clock in the case of an equally spaced energy spectrum. The non-degenerate clock Hamiltonian can be written as
where
with and dimension of the Hilbert space of our clock system. The meaning of T will become clear. Notice that we have chosen to avoid unnecessary complications. The case with can be considered as a generalization, which we do not address here. Next, we introduce the time observable by defining time states:
where
with . The states (3) exhibit a cyclic condition and the meaning of T is now clear: it represents the time taken by the clock to return to its initial state. We therefore consider three cases of interest.
For , we can introduce the Hermitian operator
where the time states provide an orthonormal and complete basis in . The operator (5) can be considered as conjugated (or a complement) to the Hamiltonian : it is indeed easy to show that is the generator of shifts in values and, vice versa, is the generator of energy shifts [21].For , the number of time states is greater than the number of energy states, and the time observable is represented by a POVM with elements . The resolution of identity is indeed still satisfied even if the time states are not orthogonal.In the limiting case , it is possible to redefine the time states as
where t is a continuous variable taking all the real values in the interval . The time observable is again described by a POVM generated with the operators , and the resolution of the identity reads as .
In the first two cases, the time values of the clock are discrete, and we can search the fundamental limit in the spacing between them. We will then see that such a limit reduces to zero in the case of , allowing us to safely consider the time values as continuous in this limiting case. Finally, we will derive a bound on the minimal resolvable interval in the clock time values.
2.2. Limit in Discretizing Time
We proceed in our analysis by considering , and we will study as a special case. From (2) and (4), we can easily calculate the spacing between two neighbors’ time eigenvalues:
where is the interval between two neighbors’ energy levels. We now search a lower limit for . The extent of the energy spectrum is , and it can be bound considering that energy cannot be arbitrarily confined in a region of space. Assuming the clock to be spherically symmetric, we thus require that (half) the diameter of the clock not be smaller than its Schwarzschild radius [3,4,8]. Denoting by the rest mass of the clock (excluding its internal energy), we therefore ask
which leads to
and finally to
where we have introduced the Planck length and the Planck time as
It is worth noting that the condition guarantees that the expression (which appears in the denominator of Equation (10)) remains positive.
In the case , where the time states are orthogonal and we can introduce the Hermitian operator , Equation (10) becomes
which imposes a bound in the minimum spacing between time values depending on the rest mass and the physical size of the clock.
For , we can instead obtain an arbitrarily small bound for by taking z to be arbitrarily large. Furthermore, under the condition (which is satisfied in any realistic scenario), Equations (10) and (7) ensure that we can safely take the limit , where time values become continuous. Indeed, as , also the constraint on tends to zero (with the same scaling) and always remains above the bound.
2.3. Limit in Resolving Time
We work here in the limit , where the time states are defined as in (6) and the continuous variable t takes all the real values in the interval . The eigenvalues of the clock Hamiltonian do not change, and they are again described by (2). Our goal is to identify a fundamental limit for the minimal resolvable interval between time values when relativistic considerations are taken into account.
In a truly relativistic framework, the concept of time is closely connected with the concept of space. The basic measurement in general relativity is indeed the measurement of distances between events in spacetime. Such measurements make the definition of a coordinate system possible. For this reason, in deriving the bound for the temporal accuracy, we consider the SW framework, in which clocks and light signals are used to measure spacetime distances [16,17]. In some sense, we are doing the opposite of what SW did: we are not looking for quantum limitations to general relativity, but, instead, we are searching the limitations that a relativistic framework imposes on quantum theory.
The distances between events in spacetime could be measured using clocks and rods, but Wigner noted, “we found that measurements with yardsticks are rather difficult to describe and that their use would involve a great deal of unnecessary complications […]. It is desirable, therefore, to reduce all measurements in spacetime to measurements by clocks” [17]. Clearly, only time-like distances between events can be measured by clocks directly, while space-like distances between events (which would naturally be measured by rods) have to be measured indirectly with the help of light signals.
Summarizing SW’s argument, the simplest framework in spacetime capable of measuring the distances between events is a set of clocks together with light signals. The clocks should be only slowly moving with respect to each other, namely with world lines approximately parallel (for a detailed discussion regarding spacetime measurements between events with clocks, we directly refer to [16,17]).
We thus consider our clock with accuracy , being able to measure time intervals up to a maximum T. The time state of the clock is given by Equation (6), which we rewrite to facilitate the reading:
Such a state evolves through orthogonal states at time values with , implying a first bound (which we will call the structural bound) on the temporal accuracy
leading to
Notice that we have already found the lower limit for in Equation (12).
We now move to the second bound for the clock. Assuming the clock as not absolutely stationary, we can think of it as having an indeterminate momentum and thus a spread in the velocity. From the Heisemberg uncertainty principle, identifying with the spread in the position, we have that such spread in the velocity is
where m denotes the inertial (and gravitational) mass of the clock (with in any realistic setting). Therefore, after a time interval (denoting the operational time), the uncertainty in the position becomes , which (given the mass m) assumes its minimum for . We emphasize here that we are imposing a strong simplification, restricting the spreads in position and velocity only to one spatial dimension. For a detailed discussion about the physical arguments underlying this assumption, we refer to [16].
We now ask that the clock position does not introduce any statistical uncertainty in the determination of time. That is, we assume that the position spread is small enough so that the uncertainty in the time at which the clock interacts with a reference event (i.e., a light signal) remains within a time interval . This can be achieved by requiring throughout the interval , namely
On the other hand, to ensure gravitational consistency, we ask that the spatial uncertainty of the clock be no smaller than (twice) its Schwarzschild radius
which leads to the requirement for the mass
Combining Equations (17) and (19), we obtain
and finally
Our derivation combines the quantum-spreading argument of SW [16,17] with a gravitational consistency condition requiring that the clock cannot be localized within its own Schwarzschild radius. This leads to a bound on the time resolution of our clock, aligning with previous analyses that have explored fundamental limits on time measurement precision (see [2,3,4,5]). In particular, we highlight the findings of Gambini and Pullin [1], who derive a similar limit based on time dilation effects.
Importantly, we have verified that including the Compton wavelength bound
together with the spreading constraint (17) and the gravitational consistency condition does not affect our result when . Indeed, in this physically relevant regime, minimizing over the clock mass m subject to all three bounds yields an optimal mass for which the spreading and gravitational constraints coincide and jointly determine the final limit, while the Compton bound is less restrictive and thus plays no role. For sufficiently small clock masses, the Compton bound would dominate. However, in such cases, it lies above the other two bounds and therefore does not lower the achievable .
For completeness, we note that, for , the optimal clock mass obtained by minimizing under the three bounds is determined by the intersection of the Compton and gravitational constraints, which sets a lower floor (this same floor also occurs at , where the optimal mass lies at the intersection of all three bounds). We reiterate, however, that all physically realistic scenarios correspond to , where (21) applies.
We emphasize that, in realistic parameter regimes such as those corresponding to currently achievable clock spectra, the structural bound dominates over our second fundamental constraint (21). Moreover, we note that, for physically accessible clock masses (typically much smaller than the mass scale optimizing the second bound), the quantum-spreading constraint becomes the relevant competitor as the second bound, so the structural one must be compared with it to determine the actual limitation on clock accuracy. Nevertheless, Equation (21) retains its role as the ultimate fundamental limitation that cannot be surpassed, even if it lies beyond the range of any physically realizable implementation.
3. Clock with Generic Spectrum
3.1. The Generalized Quantum Clock
We consider here again the clock as a quantum system described by energy states and energy levels with , but we do not assume an equally spaced energy spectrum. In this case, we cannot find a subset of time states (3) that are orthogonal, but we can make progress by requiring that the ratios are rational numbers. Thus, we can write , where and are integers with no common factors. We define for , with the lowest common multiple of the values of with , and we take . In this framework, the values are integers for all . Next, we redefine
and then
In this framework, we introduce again the time states
with . We now show that these states still satisfy the resolution of the identity. We have
Replacing the expression of on the right-hand side of Equation (26), we obtain
For a rational , and thus as an integer, we have
by virtue of the identity . Combining all the above, we thus finally obtain
We can ensure that is not a multiple of by taking , which is the largest value for . This implies that, in this new scenario, the generalized quantum clock is only described by the POVM, where the elements are given by .
As in the previous Section, since z is lower-bounded, we can take the limit , defining the time states as
where . The clock is here described by the POVM generated with the operators , and the resolution of the identity reads
To conclude this part, we emphasize that this framework allows us to use any generic (discrete) clock Hamiltonian with arbitrary (not rational) energy level ratios. In this case, the resolutions of the identity (29) and (31) are no longer exact, and the time states do not provide an overcomplete basis for the system. Nevertheless, since any real number can be approximated with arbitrary precision by a ratio between two rational numbers, the residual terms in the resolutions of the identity and consequent small corrections can be arbitrarily reduced.
3.2. Limit in Discretizing Time
As in the previous section, we search here the relativistic limit in discretizing the time values considering as finite. The spacing between neighboring time values is given again by
where, for T, from (24), we can derive the following key relation:
Equation (33) must be valid for each n and, in particular, for , leading to
where the amplitude of the energy spectrum appears explicitly in the denominator.
Combining now Equations (32) and (34), we obtain
The fundamental inequality is obtained again by requiring that (half) the diameter of the clock not be smaller than its Schwarzschild radius, namely
which, together with (35), leads to
Given the number of time states , Equation (37) shows that the limit in the discretization of time values depends on and the physical size of the clock. As in the previous section, this bound on can be made arbitrarily small by choosing to be arbitrarily large. Furthermore, also in this case, under the condition for the period T (which is always satisfied in any realistic scenario), the two Equations (32) and (37) ensure that we can safely take the limit , where time values become continuous. Indeed, while tends to zero, the constraint on also tends to zero (with the same scaling), and always remains above the bound.
3.3. Limit in Resolving Time
We briefly discuss here the limit in clock accuracy, working again in the limiting case . The main part of the discussion is essentially the same as that already covered in Section 2.3; therefore, we will not repeat it. The only difference with respect to the previous section is that, in the case of the generalized quantum clock, we no longer have a set of orthogonal time states. Thus, we resort to the quantum speed limit [35,36,37,38] to estimate the interval required for the state (30) to evolve into an orthogonal configuration. The structural bound on clock accuracy is thus [36]
where is the mean energy defined through and is given by
Notice that, by considering , together with (36) and (38), we can find the (more restrictive of the two) lower limit for , namely
which is consistent with what we found in the previous section in Equation (12).
As mentioned, when considering the relativistic SW framework, the second bound on can be directly obtained by applying the discussion developed in the previous section, leading to
which turns out to be a general limit, independent of the clock energy spectrum.
The discussion in Section 2.3 on which bound effectively constrains the clock accuracy for realistic parameter regimes still holds here. Importantly, the fact that, in the generic case, the clock period T is no longer rigidly tied to the uniform energy level spacing, but rather is determined through Equation (23), represents a major advantage in two respects. On the one hand, very small energy gaps can make T significantly larger, thereby allowing for longer operational times ; on the other hand, a generic spectrum naturally broadens the range of physical systems that can effectively function as quantum clocks. This makes the generic case particularly relevant for realistic implementations.
4. Conclusions
In conclusion, we have studied the relativistic limits in discretizing and resolving the time values of a quantum clock, originally introduced in [10] and then further developed in [11]. Our clock is represented by an observable complement of a bounded and discrete clock Hamiltonian, which can have an equally spaced or a generic spectrum: we address both cases. We emphasize again that the choice of a bounded Hamiltonian seems the most natural considering that, when we deal with quantum systems, we are always working with systems of finite dimension and the introduction of unbounded Hamiltonians with continuous spectra would not be possible.
In the case of clock Hamiltonian with equally spaced energy spectra, the (discrete) time observable can be described both by a Hermitian operator (when ) and by a POVM (when ). Continuous values for the time observable are recovered for .
For , we found that the minimum time quantum is actually limited. Nevertheless, we have seen that this limit can be arbitrarily reduced by taking an arbitrarily large , and we have shown that the bound on the minimum time quantum tends to zero in the limit . Thus, we indicated the conditions under which to safely take a continuous flow of time. When considering the minimum resolvable interval between time values, we derived two bounds through inequalities (15) and (21), where the latter is in agreement with a previous analysis performed to search for a limit in the accuracy of a time measurement [1,2,3,4,5]. As discussed, in realistic parameter regimes, the first bound (denoted as structural) largely dominates over the relativistic one and must, if anything, be compared with the quantum-spreading constraint (17) (which effectively becomes the second bound) in determining the actual clock accuracy. Equation (21) should be regarded as an ultimate, fundamental bound that cannot be surpassed, even though realizable implementations remain far from it.
Finally, we have discussed the generalization of our framework to the case of a clock with a generic spectrum. In this new scenario, we cannot find a subset of time states that are orthogonal, meaning that the time observable can only be described by the POVM. Nevertheless, also in this case, we found the limit in the discretization of the time values when they are discrete, and we showed again how to safely take the limit leading to a continuous flow of time. Then, we addressed the question of the minimal resolvable interval achievable by the generalized quantum clock. We stress once more that, in the generic case, the period T is determined by the energy spectrum through Equation (23), rather than by a fixed uniform spacing. This feature offers a twofold advantage: it allows for longer operational times whenever very small energy gaps are present, and it greatly enlarges the class of physical systems that can be employed as clocks.
However, it is important to emphasize that this work does not aim to propose a realizable clock but rather to identify fundamental limits on the structure and resolution of time values within a specific proposal of a quantum clock [10,11,12] when it is constrained by the interplay between quantum mechanics and general relativity. The derived bounds are not engineering prescriptions but theoretical constraints that define the boundary of what is physically consistent when both quantum uncertainty and relativistic effects are taken into account.
Our original contribution can thus be summarized as follows. Assuming a bounded and discrete clock Hamiltonian, for the case in which the time observable is represented by a Hermitian operator, we derived a gravitational consistency bound on the discretization of the clock values, identifying a minimum possible time quantum. In the more general case, where the time observable is described by a POVM (which also includes clocks with generic discrete spectra), we determined the condition under which the clock values can be safely treated as continuous, ensuring that this limiting procedure does not violate any constraint imposed by general relativity. Finally, we established a fundamental limit on the resolution of a quantum clock by combining quantum spreading and gravitational arguments and explicitly verifying that the Compton bound does not play a role in determining this ultimate limit. Importantly, this result is completely general, as it does not depend on the specific structure of the clock spectrum. Our discussion thus demonstrates that the fundamental bound applies not only to time measurements, as considered in the previous literature, but also to the accuracy achievable in distinguishing the values of quantum time operators, independently of the spectral properties of the clock.
As already mentioned, the time observable that we studied in this work finds suitable physical justification (and is thus widely used) within the Page and Wootters quantum time formalism [18,19]. In such a framework, time is a quantum degree of freedom that belongs to an ancillary Hilbert space and, in such a space, it is represented by a clock observable. The Page and Wootters theory is thus a protocol for internalizing the temporal reference frame, leading to a new conception of quantum time where the time observable plays a central role. In the quantum gravity literature, it has been suggested that quantum reference frames are needed in order to formulate a workable quantum theory of gravity [39,40,41,42]. We hope that our discussion will be useful in this regard, but we do not go further into the topic, since it is beyond the scope of the present work.
The reference list from the paper itself. Each links out to its DOI / PubMed record.
- 1Gambini R. Pullin J. Fundamental bound for time measurements and minimum uncertainty clocks J. Phys. Commun.2020406500810.1088/2399-6528/ab 9a 07 · doi ↗
- 2Karolyhazy F. Gravitation and quantum mechanics of macroscopic objects Nuovo Cimento A 19664239040210.1007/BF 02717926 · doi ↗
- 3Ng Y.J. van Dam H. Limit to space-time measurement Mod. Phys. Lett. A 1994933534010.1142/s 0217732394000356 · doi ↗
- 4Ng Y.J. van Dam H. Limitation to Quantum Measurements of Space-Time Distances Ann. N. Y. Acad. Sci.199575557958410.1111/j.1749-6632.1995.tb 38998.x · doi ↗
- 5Amelino-Camelia G. Limits on the measurability of space-time distances in (the semiclassical approximation of) quantum gravity Mod. Phys. Lett. A 199493415342210.1142/S 0217732394003245 · doi ↗
- 6Greiner W. Relativistic Quantum Mechanics. Wave Equations Springer Berlin/Heidelberg, Germany 200010.1007/978-3-662-04275-5 · doi ↗
- 7Peskin M.E. Schroeder D.V. An Introduction to Quantum Field Theory CRC Press Boca Raton, FL, USA 199510.1201/9780429503559 · doi ↗
- 8Rovelli C. Vidotto F. Covariant Loop Quantum Gravity: An Elementary Introduction to Quantum Gravity and Spinfoam Theory Cambridge University Press Cambridge, UK 201410.1017/CBO 9781107706910 · doi ↗
