# Retained Lead Fragments in Superior Vena Cava and Early Post-Transplant Outcomes: A Single Center Preliminary Retrospective Study

**Authors:** Federica Mazzone, Lorenzo Giovannico, Vincenzo Ezio Santobuono, Giuseppe Fischetti, Domenico Parigino, Luca Savino, Claudia Leo, Giuseppe Cristiano, Aldo Domenico Milano, Andrea Igoren Guaricci, Massimo Padalino, Marco Matteo Ciccone, Tomaso Bottio

PMC · DOI: 10.3390/biomedicines13102509 · Biomedicines · 2025-10-15

## TL;DR

This study finds that leftover parts from heart devices after transplant are linked to higher early death rates in patients.

## Contribution

The study shows for the first time that retained CIED lead fragments are independently associated with increased early post-transplant mortality.

## Key findings

- 18% of patients with pre-transplant CIEDs had retained lead fragments.
- Patients with retained fragments had significantly lower 30, 90, and 150-day survival rates.
- Retained leads were independently associated with increased mortality (HR: 3.71).

## Abstract

Background/Objectives: Retained fragments of cardiovascular implantable electronic device (CIED) leads are frequently observed after orthotopic heart transplantation (OHT), but their clinical relevance remains unclear. Methods: We conducted a single-center, retrospective study of 179 adult patients who underwent OHT between January 2022 and January 2025. Post-transplant imaging was used to identify retained lead fragments. Patients were grouped based on the presence or absence of retained leads. The primary endpoint was all-cause mortality at 30, 90, and 150 days post-transplant. Survival analysis was performed using Kaplan–Meier estimates and Cox proportional hazards modeling. Results: Among 112 patients with pre-transplant CIEDs, 18 (16%) had retained intravascular lead fragments. These patients had significantly lower survival at 30 days (66.7% vs. 94.7%), 90 days (61.1% vs. 90.3%), and 150 days (55.0% vs. 83.5%) compared to those without retained fragments (log-rank p = 0.002). The presence of retained leads was independently associated with increased mortality (HR: 3.71; 95% CI: 1.55–8.84; p = 0.003), even after adjusting for potential confounders. Conclusions: Retained CIED lead fragments are independently associated with higher early post-transplant mortality. These findings support the need for individualized intraoperative strategies to mitigate hardware-related risks in high-risk transplant candidates.

## Linked entities

- **Diseases:** cardiovascular disease (MONDO:0004995)
- **Species:** Homo sapiens (taxon 9606)

## Full-text entities

- **Species:** Homo sapiens (human, species) [taxon 9606]

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC12561180/full.md

## Figures

2 figures with captions in the complete paper: https://tomesphere.com/paper/PMC12561180/full.md

## References

18 references — full list in the complete paper: https://tomesphere.com/paper/PMC12561180/full.md

---
Source: https://tomesphere.com/paper/PMC12561180