# Telemetric intracranial pressure monitoring in patients with hydrocephalus: a systematic literature review

**Authors:** Kivanc Yangi, Daniel W. Gulick, Carlos E. Calderon Valero, Egemen Gok, Michael C. D'Saachs, Ishaan Bassi, Thomas J. On, Mark C. Preul

PMC · DOI: 10.3389/fped.2025.1632216 · Frontiers in Pediatrics · 2025-10-10

## TL;DR

This review examines telemetric intracranial pressure monitoring devices for managing hydrocephalus, showing their benefits over traditional methods and their growing use since 2011.

## Contribution

The paper provides a systematic review of telemetric ICP monitoring devices, emphasizing their adoption and clinical benefits in hydrocephalus management.

## Key findings

- Telemetric ICP monitoring offers continuous, noninvasive monitoring, improving diagnostic accuracy and treatment adjustments.
- The use of these devices has increased significantly since 2011, with most studies focusing on Raumedic and Miethke devices.
- Despite challenges like high costs and sensor drift, these devices show potential to reduce hospital admissions and invasive procedures.

## Abstract

This systematic literature review sought to examine telemetric intracranial pressure (ICP) monitoring devices, evaluate their operating principles and applications in hydrocephalus management, and highlight their advantages over traditional ICP monitoring methods.

A comprehensive search using Medical Subject Headings terms was conducted in the Medline (via PubMed), Scopus, and Embase databases for articles published in English. In accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, a strict selection process was followed. Three reviewers independently examined the full texts of the selected articles.

A total of 300 articles were retrieved, with 52 meeting the inclusion criteria after removing duplicates and noneligible studies. Telemetric ICP monitoring has been studied since the 1980s, but research remained limited until 2011 (16 [31%] studies), although it increased significantly thereafter (36 [69%] studies). The Raumedic Neurovent-P-tel was introduced in 2009, and 22 of the 36 studies published since 2011 focused solely on Raumedic devices. Likewise, after the Miethke Sensor Reservoir was released in 2015, interest in this field grew, with 9 studies evaluating Miethke devices between 2017 and 2024. Since 2019, 4 studies have reported experiences using both Raumedic and Miethke devices. Among the total of 52 studies, 11 (21%) focused on pediatric patients, 10 (19%) focused on adults, 22 (42%) included both age groups, and 9 (17%) did not specify patient age.

Telemetric ICP monitoring has emerged as a valuable tool in managing hydrocephalus, offering continuous, noninvasive monitoring that enhances diagnostic accuracy and treatment adjustments. This review highlights the increasing adoption of these devices and their potential to improve clinical outcomes while reducing hospital admissions and invasive interventions. Despite challenges such as high initial costs and sensor drift, technological advancements and further research could enhance their reliability and expand their applications in neurosurgery.

## Linked entities

- **Diseases:** hydrocephalus (MONDO:0001150)

## Full-text entities

- **Diseases:** hydrocephalus (MESH:D006849)
- **Species:** Homo sapiens (human, species) [taxon 9606]

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC12549288/full.md

## Figures

8 figures with captions in the complete paper: https://tomesphere.com/paper/PMC12549288/full.md

## References

109 references — full list in the complete paper: https://tomesphere.com/paper/PMC12549288/full.md

---
Source: https://tomesphere.com/paper/PMC12549288