# Development and validation of a novel UPLC-Q-Orbitrap HRMS method for determining p-Nitroaniline and its metabolites in blood

**Authors:** Peng Wang, Junlin Wang, Qiuliang Xu, Hua Zou, Xiangjing Gao, Hong Ren, Yiyao Cao

PMC · DOI: 10.3389/fchem.2025.1631203 · Frontiers in Chemistry · 2025-10-08

## TL;DR

A new method using advanced mass spectrometry was developed to detect p-Nitroaniline and its metabolites in blood with high accuracy and sensitivity.

## Contribution

A novel UPLC-Q-Orbitrap HRMS method was developed and validated for detecting p-Nitroaniline and its metabolites in blood.

## Key findings

- The method showed excellent linearity with correlation coefficients greater than 0.999.
- The detection limits were as low as 0.6 μg/L, making it highly sensitive.
- The method was successfully applied to blood samples from workers exposed to p-Nitroaniline.

## Abstract

An accurate, reliable, and sensitive method was successfully developed to simultaneously determine p-Nitroaniline (p-NA) and its metabolites in blood based on the hyphenated technology of quadrupole-orbitrap high resolution mass spectrometry (Q-Orbitrap HRMS) and ultra-performance liquid chromatography (UPLC). After the blood sample was extracted with ethyl acetate, the organic layer was taken for injection and analysis. Within the concentration range of 1–100 μg/L, the calibration curves of p-NA and its metabolites had a good linearity, with correlation coefficient(r) values greater than 0.999. This method has excellent precision and accuracy. The intra- and inter-day coefficients of variation (CVs) were less than 9.9% and 8.7% respectively, and the analytical accuracy ranged from 83.1% to 101.3%. The lower limits of detection (LLODs) for all target analytes were between 0.6 μg/L and 2.2 μg/L, and the lower limits of quantification (LLOQs) were between 2.0 μg/L and 7.4 μg/L. In addition, the application potential of this method was verified by analyzing the blood samples of workers exposed to p-NA. The results indicated that this method was accurate, reliable and sensitive, and was applicable to the detection of p-NA and its metabolites in the blood.

## Linked entities

- **Chemicals:** p-Nitroaniline (PubChem CID 7475), ethyl acetate (PubChem CID 8857)

## Full-text entities

- **Chemicals:** ethyl acetate (MESH:C007650), p-NA (MESH:C019498)

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC12540305/full.md

## Figures

4 figures with captions in the complete paper: https://tomesphere.com/paper/PMC12540305/full.md

## References

20 references — full list in the complete paper: https://tomesphere.com/paper/PMC12540305/full.md

---
Source: https://tomesphere.com/paper/PMC12540305