# Artifact-reference multivariate backward regression (ARMBR): a novel method for EEG blink artifact removal with minimal data requirements

**Authors:** L Alkhoury, G Scanavini, S Louviot, A Radanovic, S A Shah, N J Hill

PMC · DOI: 10.1088/1741-2552/ade566 · Journal of Neural Engineering · 2025-06-26

## TL;DR

This paper introduces a new lightweight method for removing blink artifacts from EEG data that performs well compared to existing techniques and could be used in real-time applications.

## Contribution

The novel ARMBR method enables effective blink artifact removal with minimal training data and potential for online use.

## Key findings

- ARMBR outperformed MNE native methods in reconstructing ground truth blink-contaminated EEG data.
- ARMBR had comparable or better performance than ASR and ICA+ICLabel in blink artifact removal.
- ARMBR preserved desired event-related-potential signals while removing blink artifacts in real datasets.

## Abstract

Objective. We present a novel and lightweight method that removes ocular artifacts from electroencephalography (EEG) recordings while demanding minimal training data. Approach. A robust, cross-validated thresholding procedure automatically detects the times at which eye blinks occur, then a linear scalp projection is estimated by regressing a simplified time-locked reference signal against the multi-channel EEG. Main results. Performance was compared against four commonly-used and readily available blink removal methods: signal subspace projection and forward regression (Reg) from the MNE toolbox, EEGLab’s independent component analysis (ICA) combined with ICLabel for automated component identification, and Artifact Subspace Reconstruction (ASR) Python implementation compatible with MNE. On semi-synthetic blink-contaminated EEG data, our method exhibited better reconstruction of the ground truth than the two MNE native methods, and comparable (or better in some scenarios) performance to ASR algorithm and ICA+IClabel. We also examined a real EEG dataset from 16 human participants, where the ground truth was unknown. Our method affected contaminated channels in blink intervals more than the two MNE native methods and ASR, while having a smaller impact on non-blink intervals, uncontaminated channels, and higher-frequency amplitudes, than the two MNE methods; its performance was again similar to ICA+ICLabel. On a second real dataset from 42 human participants, we showed that ARMBR removed the unwanted blink artifacts while successfully preserving the desired event-related-potential signals. Significance. The proposed algorithm exhibited comparable, and in some scenarios better performance relative to readily-available implementations of other widely-used methods. Another feature of our method is its potential as method for online applications. Therefore, it stands to make valuable contributions towards the automation of neural-engineering technologies and their translation from laboratory to clinical and other real-world usage.

## Full-text entities

- **Diseases:** eye blinks (MESH:D000092164)
- **Species:** Homo sapiens (human, species) [taxon 9606]

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC12539671/full.md

## Figures

13 figures with captions in the complete paper: https://tomesphere.com/paper/PMC12539671/full.md

## References

53 references — full list in the complete paper: https://tomesphere.com/paper/PMC12539671/full.md

---