# Case Report: False vertebral artery stenosis: an rare phenomenon

**Authors:** Yan Nao, Yang Niao, Sun Dong, Mei Bin

PMC · DOI: 10.3389/fsurg.2025.1598842 · Frontiers in Surgery · 2025-10-07

## TL;DR

A rare case shows how a catheter loop can create a false appearance of artery blockage during brain imaging procedures.

## Contribution

Identifies a previously unrecognized catheter-induced artifact causing false vertebral artery stenosis in trans-radial cerebral angiography.

## Key findings

- Simmons-2 catheter loop altered vessel angles, creating apparent stenosis.
- Preoperative stenosis resolved during intraoperative angiography.
- The artifact originated from catheter-induced vascular angle changes.

## Abstract

Trans-radial access (TRA) has gained widespread adoption in neurointerventional procedures, particularly for cerebral angiography. The success of trans-radial cerebral angiography crucially relies on the proper formation of the simmons-2 catheter loop to navigate the aortic arch and selectively catheterize the cerebral vessels. However, the potential of simmons-2 catheter loop configuration to induce angle change of the vasculature was not previously recognized in our institutional practice.

We present a rare cerebrovascular imaging phenomenon identified during diagnostic and therapeutic neurointerventional procedures in a 60-year-old male patient. Selective cerebral angiography performed via right radial access demonstrated severe ostial stenosis of the right vertebral artery. Thus, endovascular stent placement was scheduled to address the right vertebral artery stenosis via trans-radial approach. Surprisingly, intraoperative vertebral artery angiography via 6F guiding catheter demonstrated complete resolution of the preoperative stenosis. We conducted a comparative analysis of subclavian artery and brachiocephalic trunk morphology using pre- and post-loop formation angiographic imaging.

Angiographic analysis revealed that the simmons-2 catheter loop configuration resulted in a significant alteration of the angle between the horizontal subclavian artery and the descending brachiocephalic trunk, producing vertebral artery traction and apparent stenosis.

The discrepancy arose from a previously unrecognized phenomenon: simmons-2 catheter loop configuration altered the angulation between the vessels, resulting in artefactual vertebral artery ostium stenosis during initial angiography. This case reveals previously unrecognized anatomic-vascular interactions influencing for trans-radial neurointerventional procedures. This report carries significant implications for procedural techniques and image interpretation in neurointerventional practice.

## Full-text entities

- **Diseases:** stenosis (MESH:D003251), vertebral artery ostium stenosis (MESH:D014715)
- **Species:** Homo sapiens (human, species) [taxon 9606]

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC12537717/full.md

## Figures

1 figure with captions in the complete paper: https://tomesphere.com/paper/PMC12537717/full.md

## References

7 references — full list in the complete paper: https://tomesphere.com/paper/PMC12537717/full.md

---
Source: https://tomesphere.com/paper/PMC12537717