# Dual-Head Pix2Pix Network for Material Decomposition of Conventional CT Projections with Photon-Counting Guidance

**Authors:** Yanyun Liu, Zhiqiang Li, Yang Wang, Ruitao Chen, Dinghong Duan, Xiaoyi Liu, Xiangyu Liu, Yu Shi, Songlin Li, Shouping Zhu

PMC · DOI: 10.3390/s25195960 · Sensors (Basel, Switzerland) · 2025-09-25

## TL;DR

This paper introduces a new deep learning framework that enables accurate material decomposition from conventional X-ray images, reducing the need for expensive photon-counting detectors.

## Contribution

The novel Dual-head Pix2Pix framework achieves improved iodine and bone decomposition using conventional detectors, with strong generalization capabilities.

## Key findings

- Dual-head Pix2Pix outperforms baseline models in iodine and bone decomposition with lower mean absolute error.
- The model achieves higher MS-SSIM, PSNR, and Pearson correlation coefficients across benchmarks.
- It successfully generalizes to new domains, demonstrating effective separation of iodine and bone in cross-domain validation.

## Abstract

Material decomposition in X-ray imaging is essential for enhancing tissue differentiation and reducing the radiation dose, but the clinical adoption of photon-counting detectors (PCDs) is limited by their high cost and technical complexity. To address this, we propose Dual-head Pix2Pix, a PCD-guided deep learning framework that enables simultaneous iodine and bone decomposition from single-energy X-ray projections acquired with conventional energy-integrating detectors. The model was trained and tested on 1440 groups of energy-integrating detector (EID) projections with their corresponding iodine/bone decomposition images. Experimental results demonstrate that the Dual-head Pix2Pix outperforms baseline models. For iodine decomposition, it achieved a mean absolute error (MAE) of 5.30 ± 1.81, representing an ~10% improvement over Pix2Pix (5.92) and a substantial advantage over CycleGAN (10.39). For bone decomposition, the MAE was reduced to 9.55 ± 2.49, an ~6% improvement over Pix2Pix (10.18). Moreover, Dual-head Pix2Pix consistently achieved the highest MS-SSIM, PSNR, and Pearson correlation coefficients across all benchmarks. In addition, we performed a cross-domain validation using projection images acquired from a conventional EID-CT system. The results show that the model successfully achieved the effective separation of iodine and bone in this new domain, demonstrating a strong generalization capability beyond the training distribution. In summary, Dual-head Pix2Pix provides a cost-effective, scalable, and hardware-friendly solution for accurate dual-material decomposition, paving the way for the broader clinical and industrial adoption of material-specific imaging without requiring PCDs.

## Full-text entities

- **Chemicals:** iodine (MESH:D007455)

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC12526964/full.md

## Figures

2 figures with captions in the complete paper: https://tomesphere.com/paper/PMC12526964/full.md

## References

32 references — full list in the complete paper: https://tomesphere.com/paper/PMC12526964/full.md

---