## TL;DR

This study compares ultrasound risk stratification methods for thyroid nodules using video sequences versus static images, finding strong correlations but also notable differences in image quality and observer confidence.

## Contribution

The study introduces cine loop video sequences as a novel alternative to static images in thyroid nodule risk stratification.

## Key findings

- Cine loop and static image methods showed strong correlations in ultrasound features and risk ratings.
- Cine loop captured more echogenic foci but had more artifacts and lower observer confidence.
- Kwak TIRADS better reflected the benign nature of autonomously functioning thyroid nodules than ACR ratings.

## Abstract

Background/Objectives: Autonomously functioning thyroid nodules (AFTNs) are most frequently diagnosed as benign. However, they show high ratings in ultrasound (US) risk stratification systems (RSSs) that utilize the current clinical standard methodology of conventional static image capture (SIC) documentation. The objective of this study was to evaluate the RSS ratings and respective fine needle cytology (FNC) recommendations of cine loop (CL) video sequences in comparison to SIC. Methods: 407 patients with 424 AFTNs were enrolled in this unicentric, retrospective study between 11/2015 and 11/2023. Recorded US CL and SIC were analyzed lesion-wise and compared regarding US features, Kwak and ACR TIRADS, ACR FNC recommendations, as well as assessment difficulties and artifacts. Statistical analyses were conducted using the Chi2 test and Spearman’s correlation coefficient in SPSS software. p-values < 0.05 were considered significant. Results: Strong to very strong correlations were observed for all US features, RSS ratings, and ACR FNC recommendations (Spearman’s correlation: each p < 0.001), comparing CL and SIC. For >60% of the AFTNs, ACR FNC recommendation was given. Kwak TIRADS were more consistent with the benign nature of AFTNs than the ACR ratings. CL captured significantly more “echogenic foci” than SIC (Chi2: p < 0.001). Artifacts (poor image quality, acoustic shadowing, sagittal incompletely displayed AFTN) were significantly more common on CL, affecting ~40% of AFTNs, compared to ~15% on SIC (Chi2: each p < 0.05). Weak correlation was observed for assessment confidence between CL and SIC, with SIC outperforming CL (Spearman’s correlation: each p < 0.001). Conclusions: A strong correlation was identified between CL and SIC in terms of RSS ratings and ACR FNC recommendations. Kwak is a superior representative of the benign character of AFTNs than ACR. However, CL provided more detailed information while being associated with decreased observer confidence and more artifacts. Specific operator training and technical improvements, including AI implementation, could improve image quality in future.

## Full-text entities

- **Diseases:** Thyroid (MESH:D013966)
- **Chemicals:** ACR (-)
- **Species:** Homo sapiens (human, species) [taxon 9606]

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC12524186/full.md

## Figures

5 figures with captions in the complete paper: https://tomesphere.com/paper/PMC12524186/full.md

## References

47 references — full list in the complete paper: https://tomesphere.com/paper/PMC12524186/full.md

---
Source: https://tomesphere.com/paper/PMC12524186