# Bridging the Diagnostic Gap: A Rapid, Cost-Effective, and Equitable Hepatitis C Virus RNA Detection Method for Resource-Limited Settings

**Authors:** Shyam Prakash, Supriya Bharti, Ram Aasarey, Manish Saroj, Shahid Khan, Shivam Pandey

PMC · DOI: 10.7759/cureus.92101 · Cureus · 2025-09-11

## TL;DR

This paper introduces a fast and affordable HCV RNA detection method suitable for low-resource areas, using LAMP technology to enable same-day diagnosis and treatment.

## Contribution

The study presents a validated LAMP-based HCV RNA detection method that is rapid, cost-effective, and requires minimal infrastructure.

## Key findings

- LAMP methods (HNB and calcein) showed high sensitivity (99.6%) and specificity (95.6-99.2%) compared to qPCR.
- HNB-LAMP provides a visual readout without specialized equipment, while calcein-LAMP uses fluorescence under UV light.
- LAMP tests cost less than $5 and can be completed in under 60 minutes, making them ideal for resource-limited settings.

## Abstract

Hepatitis C virus (HCV) remains a major global health challenge, particularly in resource-limited settings where access to molecular diagnostics is restricted. The loop-mediated isothermal amplification (LAMP) assay offers a rapid, cost-effective alternative to polymerase chain reaction (PCR) for HCV RNA detection. Unlike PCR, LAMP uses isothermal amplification (60-65°C), eliminating the need for expensive thermal cyclers and yielding results in under 60 minutes. We evaluated two LAMP detection methods - hydroxynaphthol blue (HNB, colorimetric) and calcein (fluorescent) - against an in-house TaqMan qPCR assay. Both LAMP methods demonstrated high sensitivity (99.6%) and specificity (95.6% for HNB, 99.2% for calcein), with a broad dynamic range (10-10⁶ copies/mL). Clinical validation against real-time PCR showed strong agreement, with a positive predictive value of 98.6% and a negative predictive value of 94.4%. The HNB-LAMP assay, in particular, provides a simple visual readout (blue to sky blue), requiring no specialized equipment, while calcein-LAMP offers fluorescence-based detection under UV light. Both methods showed no significant correlation (p > 0.5), confirming their reliability. LAMP’s advantages - minimal infrastructure, ambient temperature stability, and low cost (<$5 per test) - make it ideal for decentralized testing in low-resource settings. This approach could revolutionize HCV diagnosis by enabling same-day test-and-treat strategies, improving linkage to care, and supporting global HCV elimination efforts. Future steps include field validation in remote clinics, manufacturing scale-up, and integration into point-of-care platforms to maximize accessibility. By bridging the diagnostic gap, LAMP can potentially transform HCV management in underserved regions worldwide.

## Full-text entities

- **Chemicals:** calcein (MESH:C007740), HNB (MESH:C540250)
- **Species:** Hepatitis C Virus [taxon 11103]

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC12516101/full.md

## Figures

8 figures with captions in the complete paper: https://tomesphere.com/paper/PMC12516101/full.md

## References

22 references — full list in the complete paper: https://tomesphere.com/paper/PMC12516101/full.md

---
Source: https://tomesphere.com/paper/PMC12516101