# Research on Acoustic Field Correction Vector-Coherent Total Focusing Imaging Method Based on Coarse-Grained Elastic Anisotropic Material Properties

**Authors:** Tianwei Zhao, Ziyu Liu, Donghui Zhang, Junlong Wang, Guowen Peng

PMC · DOI: 10.3390/s25154550 · Sensors (Basel, Switzerland) · 2025-07-23

## TL;DR

This paper introduces a new imaging method to improve ultrasound imaging in materials with coarse crystal structures, enhancing signal quality and defect detection accuracy.

## Contribution

A novel acoustic field correction vector-coherent total focusing imaging method is proposed for coarse-grained elastic anisotropic materials.

## Key findings

- The method improved imaging amplitude uniformity and reduced structural noise in austenitic stainless steel.
- Detection SNR for seven defects increased by 2.34 dB to 10.95 dB compared to conventional methods.
- Defect localization error was reduced from 0.1 mm to 0.05 mm.

## Abstract

This study aims to address the challenges posed by uneven energy amplitude and a low signal-to-noise ratio (SNR) in the total focus imaging of coarse-crystalline elastic anisotropic materials. A novel method for acoustic field correction vector-coherent total focus imaging, based on the materials’ properties, is proposed. To demonstrate the effectiveness of this method, a test specimen, an austenitic stainless steel nozzle weld, was employed. Seven side-drilled hole defects located at varying positions and depths, each with a diameter of 2 mm, were examined. An ultrasound simulation model was developed based on material backscatter diffraction results, and the scattering attenuation compensation factor was optimized. The acoustic field correction function was derived by combining acoustic field directivity with diffusion attenuation compensation. The phase coherence weighting coefficients were calculated, followed by image reconstruction. The results show that the proposed method significantly improves imaging amplitude uniformity and reduces the structural noise caused by the coarse crystal structure of austenitic stainless steel. Compared to conventional total focus imaging, the detection SNR of the seven defects increased by 2.34 dB to 10.95 dB. Additionally, the defect localization error was reduced from 0.1 mm to 0.05 mm, with a range of 0.70 mm to 0.88 mm.

## Full-text entities

- **Chemicals:** stainless steel (MESH:D013193)

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC12349457/full.md

## Figures

15 figures with captions in the complete paper: https://tomesphere.com/paper/PMC12349457/full.md

## References

30 references — full list in the complete paper: https://tomesphere.com/paper/PMC12349457/full.md

---
Source: https://tomesphere.com/paper/PMC12349457