# Evaluating the Accuracy and Repeatability of Mobile 3D Imaging Applications for Breast Phantom Reconstruction

**Authors:** Elena Botti, Bart Jansen, Felipe Ballen-Moreno, Ayush Kapila, Redona Brahimetaj

PMC · DOI: 10.3390/s25154596 · Sensors (Basel, Switzerland) · 2025-07-24

## TL;DR

This study compares six mobile 3D scanning apps for their accuracy in reconstructing a breast mannequin, finding that some smartphone-based tools can produce clinically useful scans.

## Contribution

The study provides a systematic evaluation of mobile 3D scanning apps using a controlled silicone breast phantom, highlighting software as the main performance driver.

## Key findings

- SureScan had the lowest mean error (2.9 mm), while Polycam showed the highest error (21.4 mm).
- Software, not hardware, was found to be the primary factor affecting accuracy.
- Scaling errors and alignment artifacts were identified as key limitations.

## Abstract

Three-dimensional imaging technologies are increasingly used in breast reconstructive and plastic surgery due to their potential for efficient and accurate preoperative assessment and planning. This study systematically evaluates the accuracy and consistency of six commercially available 3D scanning applications (apps)—Structure Sensor, 3D Scanner App, Heges, Polycam, SureScan, and Kiri—in reconstructing the female torso. To avoid variability introduced by human subjects, a silicone breast mannequin model was scanned, with fiducial markers placed at known anatomical landmarks. Manual distance measurements were obtained using calipers by two independent evaluators and compared to digital measurements extracted from 3D reconstructions in Blender software. Each scan was repeated six times per application to ensure reliability. SureScan demonstrated the lowest mean error (2.9 mm), followed by Structure Sensor (3.0 mm), Heges (3.6 mm), 3D Scanner App (4.4 mm), Kiri (5.0 mm), and Polycam (21.4 mm), which showed the highest error and variability. Even the app using an external depth sensor (Structure Sensor) showed no statistically significant accuracy advantage over those using only the iPad’s built-in camera (except for Polycam), underscoring that software is the primary driver of performance, not hardware (alone). This work provides practical insights for selecting mobile 3D scanning tools in clinical workflows and highlights key limitations, such as scaling errors and alignment artifacts. Future work should include patient-based validation and explore deep learning to enhance reconstruction quality. Ultimately, this study lays the foundation for more accessible and cost-effective 3D imaging in surgical practice, showing that smartphone-based tools can produce clinically useful scans.

## Full-text entities

- **Chemicals:** silicone (MESH:D012828)
- **Species:** Homo sapiens (human, species) [taxon 9606]

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC12349111/full.md

## Figures

7 figures with captions in the complete paper: https://tomesphere.com/paper/PMC12349111/full.md

## References

29 references — full list in the complete paper: https://tomesphere.com/paper/PMC12349111/full.md

---
Source: https://tomesphere.com/paper/PMC12349111