# Short-Term Outcomes of Partial Upper Ministernotomy for Aortic Valve Replacement Within the Learning Curve Context

**Authors:** Tomáš Toporcer, Marián Homola, Anton Bereš, Michal Trebišovský, Tomáš Lopuchovský, Štefánia Mižáková, Lukáš Vajda, Štefan Lukačín, Adrián Kolesár

PMC · DOI: 10.3390/jcdd12070254 · 2025-07-01

## TL;DR

This study compares outcomes of aortic valve replacement using partial upper mini-sternotomy versus conventional sternotomy, finding similar results despite a learning curve.

## Contribution

The study evaluates the effectiveness of partial upper mini-sternotomy during the learning curve phase for aortic valve surgery.

## Key findings

- PUMS patients had longer cardiopulmonary bypass and cross-clamping times but similar survival and hospitalization outcomes.
- Echocardiographic follow-up showed no differences in prosthetic valve performance between PUMS and MS groups.
- PUMS offers cosmetic benefits without compromising surgical outcomes compared to conventional median sternotomy.

## Abstract

Background: In recent decades, aortic valve surgery has transitioned from conventional median sternotomy (MS) to minimally invasive techniques, including partial upper mini-sternotomy (PUMS) and right anterolateral mini-thoracotomy (RAMT). This study retrospectively compares the outcomes of aortic valve replacement (AVR) using PUMS during the learning phase with those of standard MS. Methods: A retrospective analysis was conducted on patients (n = 211) who underwent AVR for aortic stenosis. They were divided into MS (n = 119) and PUMS (n = 92) groups. Various preoperative, surgical and postoperative parameters, including survival, were examined. Results: Preoperatively, the main difference was age, with PUMS patients being older (67.5 ± 7 vs. 66.5 ± 9.6; p = 0.010). PUMS patients also had longer cardiopulmonary bypass (CPB) and cross-clamping times (99 ± 25 vs. 80 ± 16 min; p < 0.002; 79 ± 18 vs. 65 ± 13 min; p < 0.024). There were no significant differences in body mass index, prosthesis size, indexed effective orifice area, hospitalisation duration or any other monitored parameter. Echocardiographic follow-up found no differences in prosthetic pressure gradients, flow velocity or paravalvular leak between the PUMS and MS groups. Survival rates were similar over 1000 days. Conclusions: The data suggest that PUMS offers comparable surgical outcomes to MS for AVR with additional cosmetic benefits, undeterred by a learning curve.

## Linked entities

- **Diseases:** aortic stenosis (MONDO:0042981)

## Full-text entities

- **Diseases:** aortic stenosis (MESH:D001024), paravalvular leak (MESH:D019559)
- **Species:** Homo sapiens (human, species) [taxon 9606]

## Figures

5 figures with captions in the complete paper: https://tomesphere.com/paper/PMC12295865/full.md

---
Source: https://tomesphere.com/paper/PMC12295865