# Tissue classification from raw diffusion‐weighted images using machine learning

**Authors:** Guangyu Dan, Cui Feng, Zheng Zhong, Kaibao Sun, Ping‐Shou Zhong, Daoyu Hu, Zhen Li, Xiaohong Joe Zhou

PMC · DOI: 10.1002/mp.17810 · 2025-04-08

## TL;DR

This study introduces a machine learning method called MODEM to classify tissues using raw diffusion MRI data, outperforming traditional models in detecting and staging cervical cancer.

## Contribution

MODEM is a novel model-free machine learning approach for tissue classification using raw diffusion-weighted images without relying on predefined diffusion models.

## Key findings

- MODEM outperformed five diffusion models in simulated data with high noise levels.
- MODEM achieved 91.9% accuracy in cervical cancer detection and 69.2% in staging.
- MODEM showed significantly higher AUC values than existing models in both detection and staging.

## Abstract

In diffusion‐weighted imaging (DWI), a large collection of diffusion models is available to provide insights into tissue characteristics. However, these models are limited by predefined assumptions and computational challenges, potentially hindering the full extraction of information from the diffusion MR signal.

This study aimed at developing a MOdel‐free Diffusion‐wEighted MRI (MODEM) method for tissue differentiation by using a machine learning (ML) algorithm based on raw diffusion images without relying on any specific diffusion model. MODEM has been applied to both simulation data and cervical cancer diffusion images and compared with several diffusion models.

With Institutional Review Board approval, 54 cervical cancer patients (median age, 52 years; age range, 29–73 years) participated in the study, including 26 in the early FIGO (International Federation of Gynecology and Obstetrics) stage (IB, 16; IIA, 10) and 28 the late stage (IIB, 8; IIIB, 14; IIIC, 1; IVA, 3; IVB, 2). The participants underwent DWI with 17 b‐values (0 to 4500 s/mm2) at 3 Tesla. Synthetic diffusion MRI signals were also generated using Monte‐Carlo simulation with Gaussian noise doping under varying substrates. MODEM with multilayer perceptron and five diffusion models (mono‐exponential, intra‐voxel incoherent‐motion, diffusion kurtosis imaging, fractional order calculus, and continuous‐time‐random‐walk models) were employed to distinguish different substrates in the simulation data and differentiate different pathological states (i.e., normal vs. cancerous tissue; and early‐stage vs. late‐stage cancers) in the cervical cancer dataset. Accuracy and area under the receiver operating characteristic (ROC) curve were evaluated. Mann–Whitney U‐test was used to compare the area under the curve (AUC) and accuracy values between MODEM and the five diffusion models.

For the simulation dataset, MODEM produced a higher AUC and better accuracy, particularly in scenarios where the noise level exceeded 5%. For the cervical cancer dataset, MODEM yielded the highest AUC and accuracy in cervical cancer detection (AUC, 0.976; accuracy, 91.9%) and cervical cancer staging (AUC, 0.773; accuracy, 69.2%), significantly outperforming any of the diffusion models (p < 0.05).

MODEM is useful for cervical cancer detection and staging and offers considerable advantages over analytical diffusion models for tissue characterization.

## Linked entities

- **Diseases:** cervical cancer (MONDO:0002974)

## Full-text entities

- **Diseases:** cervical cancer (MESH:D002583), cancerous (MESH:D009369)
- **Species:** Homo sapiens (human, species) [taxon 9606]

## Figures

7 figures with captions in the complete paper: https://tomesphere.com/paper/PMC12257445/full.md

---
Source: https://tomesphere.com/paper/PMC12257445