# Three-Dimensional Transesophageal Echocardiography Is Useful for Preventing Prosthetic-Patient Mismatch After Surgical Aortic Valve Replacement

**Authors:** Kazuki Yoshida, Haruka Sasaki, Hiroyuki Takaoka, Moe Matsumoto, Yusei Nishikawa, Yoshitada Noguchi, Shuhei Aoki, Katsuya Suzuki, Satomi Yashima, Makiko Kinoshita, Noriko Suzuki-Eguchi, Shuichiro Takanashi, Kazuyuki Matsushita, Goro Matsumiya, Yoshio Kobayashi

PMC · DOI: 10.3390/jcm14134762 · 2025-07-05

## TL;DR

Using 3D transesophageal echocardiography before surgery helps choose the right valve size and reduce the risk of poor outcomes after aortic valve replacement.

## Contribution

This study shows that preoperative 3D-TEE improves valve size selection and prevents prosthetic-patient mismatch.

## Key findings

- PPM occurred in 2.9% of patients after SAVR.
- Using a valve smaller than the recommended size was strongly linked to PPM.
- 3D-TEE-based valve sizing is an independent predictor for preventing PPM.

## Abstract

Introduction: Prosthesis-patient mismatch (PPM) in surgical aortic valve replacement (SAVR) is known to be a poor prognostic factor. However, the parameters for preventing postoperative PPM in SAVR have not been established. Materials and Methods: Two hundred and five patients (mean age 72.5 ± 7.4 years, 129 males) who underwent SAVR were analyzed. Preoperatively, we determined the recommended prosthesis valve size from the mean aortic valve (AV) diameter derived from the AV annulus area by preoperative three-dimensional transesophageal echocardiography (3D-TEE). We investigated the association between pre- and postoperative changes in annulus diameter and the occurrence of PPM. Results: PPM was present in 6 patients (2.9%). Pre- and postoperative AV annulus diameter change ratio was greater in the group with PPM than in that without PPM (10.4 ± 3.6% vs. 3.0 ± 5.6%, p = 0.002). The use of prosthetic valve rings smaller than the recommended size was higher in the group with PPM than in that without PPM. (83.3% vs. 20.6%, p = 0.002). On multivariate logistic regression analysis, use of a valve smaller than the recommended size was an independent predictor of PPM (odds ratio 19.3, 95% confidence interval 2.14–174.5, p = 0.008). Conclusions: The recommended prosthetic AV size based on preoperative 3D-TEE is useful for determining the optimal prosthetic AV size to prevent PPM after SAVR.

## Full-text entities

- **Species:** Homo sapiens (human, species) [taxon 9606]

## Figures

3 figures with captions in the complete paper: https://tomesphere.com/paper/PMC12251291/full.md

---
Source: https://tomesphere.com/paper/PMC12251291