# Objective Effects and Patient Preferences for Ambulatory Oxygen in Fibrotic Interstitial Lung Disease With Isolated Exertional Hypoxaemia: A Placebo‐Controlled 6‐Minute Walk Test Study

**Authors:** Giuseppina Ciarleglio, Paolo Cameli, David Bennett, Behar Cekorja, Paola Rottoli, Elisabetta A. Renzoni, Piersante Sestini, Elena Bargagli

PMC · DOI: 10.1111/resp.70020 · 2025-03-11

## TL;DR

Ambulatory oxygen improves walking ability and reduces breathlessness in patients with fibrotic lung disease, more than placebo.

## Contribution

This study provides strong evidence that ambulatory oxygen has real benefits beyond placebo in fibrotic interstitial lung disease.

## Key findings

- Ambulatory oxygen increased walking distance by 37 meters compared to placebo.
- Patients preferred ambulatory oxygen over placebo and reported less dyspnoea and fatigue.
- Some patients had a negative perception of oxygen, which may affect treatment acceptance.

## Abstract

The available evidence on the effects of ambulatory oxygen on exercise impairment in patients with fibrotic interstitial lung diseases (F‐ILD) is of limited quality.

We conducted a randomised, double‐blind, placebo‐controlled crossover trial with 32 normoxaemic F‐ILD patients, desaturating to ≤ 88% during a baseline 6‐minute walk test (6MWT) on ambient air. After determining the oxygen flow needed to prevent desaturation, patients completed two double‐blind 6MWTs with either oxygen or placebo (compressed medical air) at the same personalised flow. Objective measures included oxygen saturation, pulse rate, and distance walked. Patient‐reported outcomes, assessed via visual analogue scales, included end‐of‐test dyspnoea, fatigue, and preferences for walking with oxygen or placebo versus each other and ambient air.

Ambulatory oxygen, compared to placebo, prevented desaturation, reduced tachycardia, increased walking distance by 37 m (95% CI: 10–74, p = 0.008), and lessened dyspnoea and fatigue. The mean preference score for oxygen over placebo was 2.6 (95% CI: 1.9–3.2, p < 0.0005), significantly greater than equivalence. The preference score for placebo over ambient air was −1.5 (−2.4 to 0.64, p = 0.005), significantly lower than equivalence, while the score for oxygen over ambient air was 0.4 (−0.7 to 1.5), not significantly different from equivalence.

Our data confirm that ambulatory oxygen provides significant benefits beyond a placebo effect; although in some patients it is associated with a negative perception that may hinder treatment acceptance. This strengthens the evidence supporting current recommendations and suggests that incorporating patient preferences recorded at the time of the 6MWT into clinical discussions can aid shared decision making regarding ambulatory oxygen.

Trial Registration:
ClinicalTrials.gov identifier: NCT02668029

In a double‐blind, placebo‐controlled 6‐minute walk test study, patients with Fibrotic Interstitial Lung Diseases and exertional breathlessness with hypoxaemia experienced less dyspnoea and fatigue, walked farther, and preferred ambulatory oxygen at a flow rate preventing desaturation, compared to medical air at the same flow rate.

## Full-text entities

- **Diseases:** tachycardia (MESH:D013610), fatigue (MESH:D005221), F-ILD (MESH:D017563)
- **Species:** Homo sapiens (human, species) [taxon 9606]

## Figures

3 figures with captions in the complete paper: https://tomesphere.com/paper/PMC12231771/full.md

---
Source: https://tomesphere.com/paper/PMC12231771