Patient Self-Scanning for Lung Ultrasound: A Prospective Observational Study on the Feasibility and Diagnostic Accuracy of a Telemedicine Protocol
Katharine T Clark, Kathleen McFadden, Benjamin A Krauss, Lachlan Driver, Irene W Ma, Rachel Vivian, Jamie Gullikson, Lauren Selame, Calvin K Huang, Andrew S Liteplo, Hamid Shokoohi

TL;DR
This study shows that patients can successfully perform their own lung ultrasounds with brief video instructions, supporting the use of telemedicine for remote care.
Contribution
Demonstrates the feasibility and diagnostic potential of patient-performed lung ultrasound for telemedicine applications.
Findings
Patients achieved high comfort and willingness to perform lung ultrasound with minimal instruction.
Most patient-obtained images were interpretable, though provider images scored higher overall.
Inter-rater reliability for image quality was good, indicating consistent evaluation by trained physicians.
Abstract
Objective: To evaluate the feasibility and diagnostic accuracy of patient-performed lung ultrasound (P-PLUS) for telemedicine purposes. Methods: This prospective observation study included patients over 18 years old who presented to a tertiary care hospital's emergency department. Patients were provided a five-minute instructional video on a US protocol of four lung zones and then performed the protocol while being monitored by a study investigator. The physician sonographer subsequently repeated the protocol. Two emergency physicians with US fellowship training blindly reviewed and independently rated image quality on a scale of one to five, with a score of three or more considered interpretable. Inter-rater reliability was estimated using the intraclass correlation coefficient. Wilcoxon-Mann-Whitney tests and chi-square tests were used to compare group differences. Results: A total…
Genes, proteins, chemicals, diseases, species, mutations and cell lines named across the full text — each resolved to its canonical identifier and authoritative record.
| Baseline characteristics | N (%) |
| Mean age (SD) | 54.2 (17.0) |
| Sex | |
| Male | 31 (55) |
| Female | 25 (45) |
| Mean body mass index (SD) | 28.3 (5.2) |
| Ethnicity | |
| Hispanic | 5 (9) |
| Non-Hispanic* | 49 (91) |
| Self-identified race | |
| White | 46 (84) |
| Black or African American | 5 (9) |
| Other | 4 (7) |
| Self-reported English proficiency | |
| Native speaker | 51 (91) |
| Non-native speaker but fluent in English | 5 (9) |
| Preferred language | |
| English | 55 (98) |
| Spanish | 1 (2) |
| Other | 0 |
| Highest level of education | |
| High school or General Educational Development (GED) diploma | 12 (21) |
| Some college | 14 (25) |
| College degree | 16 (29) |
| Postgraduate degree | 14 (25) |
| Works in the medical field | 10 (18) |
| Has a family member who works in the medical field | 24 (43) |
| Use technology heavily at work (computers, cell phones, tablets) | 40 (71) |
| Median comfort using computer (1-5) | 4.5 (IQR 3-5) |
| Has had a lung or cardiac ultrasound (echo) | 30 (54) |
| Handedness | |
| Right | 51 (91) |
| Left | 4 (7) |
| Plays video games | 11 (20) |
| Sends pictures or videos via phone or computer | 37 (66) |
| Has access to a smartphone | 37 (93) |
| Has high-speed internet at home | 52 (93) |
| Patients' scanning characteristics | |||
| Median scan duration (N minutes, IQR, range) | 7 | 4-10.5 | 3-19 |
| Number able to find the correct probe (N (%)) | 52 (93) | ||
| Number able to apply gel (N (%)) | 56 (100) | ||
| Number able to press record (N (%)) | 53 (95) | ||
| Number of times video viewed (N, IQR, range) | 1 | 1-1 | 1-2 |
| Median comfort with performing LUS (N, IQR, range) | 4 | 3.5-5 | 1-5 |
| Median willingness to perform LUS (N, IQR, range | 4 | 4-5 | 1-5 |
| Type of assistance needed | Video alone | Online materials | Virtual expert | In-person expert | Complete Inability to perform |
| N(%) | 35 (63) | 11 (20) | 7 (13) | 3 (5) | 0 (0) |
| Location of image acquisition | Right anterior chest | Right lateral chest | Left anterior chest | Left lateral chest |
| Number of complete scans | 54 (96) | 39 (70) | 52 (93) | 35 (63) |
| Type of instruction required | ||||
| Video alone | 35 (63) | 41 (75) | 44 (79) | 42 (75) |
| Minimum instruction | 16 (29) | 9 (16) | 8 (14) | 8 (14) |
| Multiple instructions | 4 (7) | 4 (7) | 3 (5) | 4 (7) |
| Manually assist the patient | 1 (2) | 4 (7) | 0 | 1 (2) |
| Unable to perform LUS | 0 (0) | 1 (2) | 1 (2) | 1 (2) |
| Chest location | Physician-performed | Patient-performed | Wilcoxon MW p-value |
| Median R anterior chest avg quality score | 4.5 IQR 3.5-5.0 | 3.5 IQR 2.5-4.0 | <0.0001 |
| Median R lateral chest avg quality score | 3.5 (3.0-4.5) | 3.0 (2.5-4.0) | 0.0023 |
| Median L anterior chest avg quality score | 4.0 (4.0-4.5) | 3.5 (3.0-4.0) | <0.0001 |
| Median L lateral chest avg quality score | 3.5 (2.5-4.0) | 2.5 (1.5-3.5) | 0.0004 |
| Using an average quality score of 3 or more as interpretable quality (Chi-square p-values presented) | |||
| R anterior chest | 50/55 (91%) | 39/56 (60%) | 0.64 |
| R lateral chest | 46/55 (84%) | 32/56 (57%) | 0.96 |
| L anterior chest | 53/56 (95%) | 45/56 (80%) | 0.38 |
| L lateral chest | 39/54 (72%) | 22/55 (40%) | 0.58 |
| Scan location | ICC | 95%% CI | p-value | ICC interpretation |
| R anterior chest by the patient | 0.84 | 0.73-0.91 | <0.001 | Good |
| R anterior chest by the MD | 0.60 | 0.33-0.77 | <0.001 | Moderate |
| R lateral chest by the patient | 0.85 | 0.74-0.91 | <0.001 | Good |
| R lateral chest by the MD | 0.60 | 0.32-0.77 | <0.001 | Moderate |
| L anterior chest by the patient | 0.65 | 0.41-0.80 | <0.001 | Moderate |
| L anterior chest by the MD | 0.56 | 0.26-0.74 | 0.001 | Moderate |
| L lateral chest by the patient | 0.86 | 0.75-0.92 | <0.001 | Good |
| L lateral chest by the MD | 0.59 | 0.29-0.76 | <0.001 | Moderate |
Peer Reviews
No public reviews on file for this paper yet. If you reviewed it on a platform where reviews are public (OpenReview, ICLR, NeurIPS, ICML), you can paste yours below so the community can read it here.
Videos
No videos yet. Explain this paper in a talk, walkthrough, or lecture? Add one.
Taxonomy
TopicsUltrasound in Clinical Applications · Radiation Dose and Imaging · Radiology practices and education
Introduction
Lung ultrasound (LUS) is a valuable tool for evaluating patients with dyspnea in the emergency department [1-3], as it has a higher sensitivity than chest X-ray in detecting various pulmonary conditions [3-7] and is cost-effective, portable, and time-efficient. During the recent COVID-19 pandemic, LUS was particularly useful in evaluating patients with suspected COVID-19 infection and helped to reduce provider exposure to infectious patients [8, 9-13].
Recent studies have demonstrated that novice patients can be taught to self-perform LUS with the guidance of experts via telemedicine [14-18], showing the feasibility of self-performed US surveillance of lung health in at-risk patients. However, these studies have required the real-time direction and supervision of expert ultrasonographers, and it is not yet known if patients can self-perform LUS remotely without the aid of real-time mentoring by experts. The ability of patients to self-perform LUS without real-time expert guidance could decrease both the monetary costs and opportunity costs (in terms of time and provider availability) associated with retaining a clinician on call to guide scanning.
This study aims to evaluate the feasibility and diagnostic accuracy of patient-performed LUS (P-PLUS) using minimal video-based instruction, without real-time expert guidance. We hypothesized that patients could independently acquire diagnostically useful LUS images with minimal tele-guidance and that these images would be accurately interpreted by expert sonographers. By assessing image quality, patient comfort, and usability across different lung zones, this study explores whether P-PLUS could support remote patient monitoring, particularly for individuals with respiratory illnesses who require ongoing evaluation. Our findings may inform the development of patient-centered telemedicine protocols and expand access to point-of-care imaging in home and low-resource settings, offering a potential shift in how US is used outside traditional clinical environments.
Materials and methods
Participant enrollment
This study was a prospective, observational study enrolling English-speaking patients aged 18 or older presenting to the ED of a tertiary care center. In a convenience-based sampling method, subjects, some with pulmonary symptoms and others without, were identified by examining the chief complaints in the ED electronic medical record and after discussion with the clinical team caring for enrolled patients. Patients who were hemodynamically unstable, had altered mental status, or had pulmonary symptoms secondary to trauma were excluded. Patients were not excluded on the grounds of race, gender, or ethnicity. Informed consent for participation was obtained for all participants by a research team member. The Institutional Review Board (IRB) of Mass General Brigham, Boston, MA, approved this study (approval number: 2020P002611). Because this was a prospective feasibility study aimed at assessing whether patients could independently perform LUS using video instruction, a formal sample size calculation was not performed, as the goal was to observe technical capability and general trends in image quality.
Patients watched a five-minute instructional video via a portable handheld iPad (Apple Inc., Cupertino, CA). Participants could pause, rewind, and replay the video as needed. The video described performing a four-zone LUS scan (right superior anterior, left superior anterior, right hemidiaphragm, left hemidiaphragm) to obtain a clip of the anterior chest in the midclavicular line and the lateral chest in the midaxillary line at the anticipated level of the lung-diaphragm interface. In our protocol, the left anterior chest refers to scanning the upper and mid portions of the thorax in the midclavicular line, while the left hemidiaphragm refers more specifically to the lower chest zone where the lung and diaphragm interface, typically approached from a more inferior and lateral angle around the posterior axillary line. Participants were provided with a handout to illustrate the technique. The handout included images that patients were expected to obtain to be used as a reference, as desired. The ultrasound machines used were standard equipment in the ED, and we dedicated a Mindray TE7 (Mindray North America, Mahwah, NJ) for the purpose of completing this study. The Mindray TE7 ultrasound system was used with a Mindray C62 convex transducer (Mindray North America). Scans were performed using the standard lung preset.
Scanning protocol
The scanning protocol for the study included the following steps: First, patients watched an instructional video on a four-zone LUS protocol. Using a Mindray C62 ultrasound transducer (Mindray North America), patients obtained images of the four zones of the lung, recording short clips when they felt they had achieved an adequate image at each point. The six-second clips were labeled with zones 1-4, corresponding to the specific zone being scanned, and the images were wirelessly stored on the Visage Imaging System (Visage Imaging, Inc., San Diego, CA). Next, an expert sonographer repeated the four-point LUS protocol, using the same ultrasound transducer and following the same instructions as the patients. Finally, the findings noted by the investigator were shared with the clinical team in real time.
Data collection and scoring
After the images were obtained, patients completed a survey using a five-point Likert scale, which examined their willingness and comfort to perform the study independently. They were also asked to rate their hypothetical willingness to complete self-scans as part of home monitoring. Demographic data and clinical information were collected from the patient's electronic medical records, including their levels of education and previous experience with technology.
The images were then deidentified, and two fellowship-trained attending physicians who were blind to whether the images were obtained by the patient or the sonographer independently reviewed and scored the images. The physicians rated the image quality on a Likert scale from one to five, with a score of three or higher considered interpretable. They evaluated the images for diagnostic quality and recorded any pathological findings, such as pleural effusion, B lines, subpleural consolidation, or pleural irregularity.
Statistical analyses
Survey questions used a five-point Likert scale to assess comfort and willingness, though the instrument was not formally validated. Statistical analyses were performed using Wilcoxon-Mann-Whitney and chi-squared tests to compare group differences in the evaluation of interpretable videos and quality scores of patient-acquired scans versus physician sonographer scans. Inter-rater reliability between the two reviewers was also assessed using the intraclass correlation coefficient (ICC). More specifically, Wilcoxon-Mann-Whitney tests were used to compare image quality scores due to the ordinal nature of the Likert scale ratings and non-normal distribution of quality scores. Chi-square tests were used to compare the proportions of interpretable images. These non-parametric tests were selected to accommodate the categorical and non-normally distributed data. All analyses were conducted using SAS v9.4 (SAS Institute Inc., Cary, NC) and IBM SPSS Statistics software, version 26 (IBM Corp., Armonk, NY).
Results
Fifty-six patients participated in this prospective observational study (Table 1).
A total of 417 LUS scan clips were collected from patient-performed and physician-sonographer-acquired scans. For the novice scanners, the median duration of the scans was seven minutes (interquartile range (IQR): four minutes to 10.5 minutes), with a range of three to 19 minutes. The majority of participants were able to find the correct probe, and all participants were able to apply the gel for the US. Fifty-three (95%) of the participants could press the US machine's record button. Most participants watched the instructional video only once (IQR: 1-1; range: 1-2) (Table 2).
In reference to the potential future home-based individual scans, 35 (63%) felt that the video was sufficient instruction alone, and 18 (33%) expressed they may need some access to online material or virtual expert instruction if they had to repeat scans at their own home (Table 3).
The majority were also able to complete the four-point lung US protocol using the instructional video alone, with the exception of the left lung base, where 12 (21%) required additional verbal instructions and one (2%) required manual assistance. Overall, patients reported high comfort in performing the self-LUS (median score: 4, IQR: 3.5-5) and high willingness to perform it again in the future (median score: 4, IQR: 4-5) (Table 4).
In general, the quality of cine loops obtained by the experts was higher than that obtained by the patients. Differences in quality reached statistical significance for all areas of the chest wall. The left hemidiaphragm had the highest proportion of interpretable patient-obtained images, while the right anterior chest had the lowest. The lower interpretability rates for patient-acquired images of the left hemidiaphragm likely reflect the increased technical difficulty in locating this interface, especially for novice users without real-time guidance. Yet, despite differences in quality, the majority of patient-performed clips were still deemed interpretable. The percentage of interpretable images was higher for expert-obtained scans (Table 5).
Inter-rater reliability of image quality scores was good, with an ICC of 0.80 (95% CI: 0.76-0.84; p<0.001). Agreement between the two raters regarding interpretability varied from moderate to good, depending on the region, with an overall agreement for the decision of interpretability being moderate (Kappa = 0.54, 95% CI 0.44-0.63, p<0.001) (Table 6).
Table 6: ICC with agreement by area of chest wall. Reviewer agreement of scores is good when all clips were combined: ICC = 0.80, 95% CI 0.76-0.84; P<0.001. Overall agreement for decision regarding interpretable or not (3 and above or <3); considered only Moderate: Kappa = 0.54, 95% CI 0.44-0.63; P<0.001ICC: intraclass correlation coefficients; MD: Doctor of Medicine; R: right; L: left
Discussion
In this study, we evaluated the feasibility and diagnostic accuracy of P-PLUS for telemedicine purposes. The results of this study demonstrate that with minimal video-based instruction, patients can obtain interpretable LUS images in all views. This is a promising finding, as it suggests that P-PLUS has the potential to be used as a tool for remote patient monitoring in the future. This includes monitoring clinically stable patients from home using handheld US devices. While interest in remote imaging was accelerated by the COVID-19 pandemic, the value of P-PLUS extends to other chronic respiratory and cardiovascular conditions. In particular, patients with heart failure or chronic obstructive pulmonary disease (COPD) may benefit from routine, at-home scanning as part of a remote care model. This is particularly important for patients with chronic pulmonary infections and stable pulmonary edema whose clinical course may be prolonged and have unpredictable changes in acuity [18, 19].
However, the results of this study also showed that the proportion of interpretable images was lower for patient-obtained images compared to expert-obtained images. This finding is consistent with previous studies showing that novice ultrasonographers may have difficulty obtaining high-quality images [17-19]. Additionally, the mean image scores were significantly higher for expert-obtained images, indicating a potential difference in image quality between patient-obtained and expert-obtained images. However, previous studies found that in almost all cases, novice users who received guidance from experts via live tele-US were able to independently obtain interpretable images of the lateral and anterior lung chest [15, 17]. In contrast, our study involved patients independently obtaining images without live or remote guidance. This suggests that patient-performed US may be a feasible and efficient alternative for home-based care and remotely performed US. Our study highlights a more scalable approach that could reduce reliance on clinician supervision in future tele-US applications. Given variability in patient performance, this points to the need for targeted training tools or supplemental guidance to ensure diagnostic reliability. Future studies should also compare patient performance with and without tele-US support to determine whether real-time feedback improves consistency and quality.
The results of the study may be limited by its single-center design and small sample size, which may not be representative of the larger population and may not have sufficient power to detect significant differences. This study was designed as a preliminary investigation of feasibility and was not powered to detect outcome differences. Therefore, a formal sample size calculation was not performed. Future multi-site studies with larger and more diverse populations are needed to validate these findings and assess performance across varying clinical and demographic contexts. The lack of diversity in the study sample, for example, which was predominantly white, English-speaking, and highly educated, may limit the generalizability of the results to other demographic groups, including more diverse or underserved populations. Future research should aim to include a broader demographic range to assess usability and performance across different patient backgrounds. Participants may also have been more motivated or technologically comfortable than the general population, introducing a possible selection bias that further limits generalizability. Furthermore, although patient diagnosis was not formally collected or analyzed in this study, future research should evaluate whether specific clinical conditions, such as pulmonary disease, obesity, or prior imaging experience, affect image quality or patient performance. Factors such as age, prior technology use, and clinical stability may have impacted performance but were not adjusted for in this analysis. Future work should explore these confounding factors through stratified analysis or multivariate modeling.
Self-reported measures of diagnostic accuracy may be subject to bias and may not be as reliable as those obtained by a trained professional. The study may not have adequately controlled for other factors that could influence the accuracy of the diagnostic test, such as the patient's knowledge or experience with US, physical condition, or other medical conditions. The study has not adequately evaluated the long-term effectiveness of P-PLUS in improving diagnostic accuracy and patient outcomes.
Additionally, for image acquisition, the Mindray TE7 was selected primarily because it was the standard US machine readily available in our ED at the time of the study. Although the TE7 is not a handheld device, it allowed us to evaluate patient scanning in a consistent and controlled clinical environment, serving as a practical first step for assessing feasibility. Because the TE7 is a cart-based US system, it may not reflect the equipment available in home or low-resource environments. Future studies should incorporate handheld devices to better assess real-world applicability in remote care settings, as well as to better reflect real-world home use and assess whether device type affects image quality, usability, or patient performance.
Although expert sonographers performed scans using the same protocol, these were not intended to serve as a formal control group. Future studies should include provider-performed scans under similar conditions as a benchmark for image quality and diagnostic utility. While this study focused on technical feasibility, future research should explore the downstream clinical value of P-PLUS, including its effect on clinical decision-making, time to diagnosis, and patient outcomes in home-monitoring scenarios.
Despite these limitations, the high levels of comfort and willingness to perform P-PLUS among patients suggest that this method of remote patient monitoring, which could be used for patients with chronic respiratory conditions or those recovering from infections such as COVID-19, has the potential to be well-received by patients. While this study supports the feasibility of P-PLUS, further research is needed to determine whether such scans can influence clinical decision-making or detect early changes in disease progression and whether that improves patient outcomes in chronic care settings and in real-world clinical settings. In addition, the use of artificial intelligence (AI) in interpreting self-acquired LUS images has the potential to improve the accuracy and efficiency of P-PLUS in remote patient care [20]. Further research is needed to evaluate AI use in P-PLUS and determine the optimal training and instruction methods for patients to perform P-PLUS with the highest accuracy. Future studies should evaluate how AI-guided feedback or automated interpretation might support novice users and improve diagnostic reliability in self-performed LUS.
Conclusions
In conclusion, our findings show that patients can successfully obtain interpretable LUS images in all views with minimal video-based instruction. While some difficulty was observed in obtaining images of the left hemidiaphragm, overall, patients demonstrated a high level of comfort and willingness to perform the procedure. These results support the potential use of P-PLUS as a tool for remote patient care. Further research is needed to optimize the training and instruction methods for patients to perform P-PLUS with the highest accuracy and to evaluate the use of AI in interpreting self-acquired LUS images.
The reference list from the paper itself. Each links out to its DOI / PubMed record.
- 1BLUE-protocol and FALLS-protocol: two applications of lung ultrasound in the critically ill Chest Lichtenstein DA 1659167014720152603312710.1378/chest.14-1313 · doi ↗ · pubmed ↗
- 2The role of ultrasound lung artifacts in the diagnosis of respiratory diseases Expert Rev Respir Med Soldati G Demi M Smargiassi A Inchingolo R Demi L 1631721320193061641610.1080/17476348.2019.1565997 · doi ↗ · pubmed ↗
- 3Integrating point-of-care ultrasound in the ED evaluation of patients presenting with chest pain and shortness of breath Am J Emerg Med Buhumaid RE St-Cyr Bourque J Shokoohi H Ma IW Longacre M Liteplo AS 2983033720193041336910.1016/j.ajem.2018.10.059 · doi ↗ · pubmed ↗
- 4Lung ultrasound is an accurate diagnostic tool for the diagnosis of pneumonia in the emergency department Emerg Med J Cortellaro F Colombo S Coen D Duca PG 19232920122103055010.1136/emj.2010.101584 · doi ↗ · pubmed ↗
- 5Hand-held thoracic sonography for detecting post-traumatic pneumothoraces: the Extended Focused Assessment with Sonography for Trauma (EFAST)J Trauma Kirkpatrick AW Sirois M Laupland KB 2882955720041534597410.1097/01.ta.0000133565.88871.e 4 · doi ↗ · pubmed ↗
- 6Comparative diagnostic performances of auscultation, chest radiography, and lung ultrasonography in acute respiratory distress syndrome Anesthesiology Lichtenstein D Goldstein I Mourgeon E Cluzel P Grenier P Rouby JJ 91510020041469571810.1097/00000542-200401000-00006 · doi ↗ · pubmed ↗
- 7Lung ultrasound in critically ill patients: comparison with bedside chest radiography Intensive Care Med Xirouchaki N Magkanas E Vaporidi K 148814933720112180910710.1007/s 00134-011-2317-y · doi ↗ · pubmed ↗
- 8Lung ultrasound in the critically ill Ann Intensive Care Lichtenstein DA 1420142440116310.1186/2110-5820-4-1PMC 3895677 · doi ↗ · pubmed ↗