# Novel Pulsed Electromagnetic Field Device for Rapid Structural Health Monitoring: Enhanced Joint Integrity Assessment in Steel Structures

**Authors:** Viktors Mironovs, Yulia Usherenko, Vjaceslavs Zemcenkovs, Viktors Kurtenoks, Vjaceslavs Lapkovskis, Dmitrijs Serdjuks, Pavels Stankevics

PMC · DOI: 10.3390/ma18122831 · 2025-06-16

## TL;DR

A new PEMF device is developed for non-destructive testing of steel joints, showing improved detection of structural changes and degradation.

## Contribution

A novel PEMF device with enhanced sensitivity for rapid structural health monitoring of steel joints is introduced.

## Key findings

- The 4 mm steel plate configuration showed a 15% reduction in high-frequency components compared to the 8 mm plate.
- A 10% increase in volumetric porosity caused a 7% downward shift in resonant frequencies.
- The PEMF system combined with the coaxial correlation method improved early-stage degradation detection by 30%.

## Abstract

This study investigates a novel pulsed electromagnetic field (PEMF) device for dynamic testing and structural health monitoring. The research utilises a PEMF generator CD-1501 with a maximum energy capacity of 0.5 kJ and a flat multifilament coil (IC-1) with a 100 mm diameter. Experiments were conducted on a model steel stand with two joint configurations, using steel plates of 4 mm and 8 mm thickness. The device’s efficacy was evaluated through oscillation pattern analysis and spectral characteristics. Results demonstrate the device’s ability to differentiate between joint states, with the 4 mm plate configuration showing a 15% reduction in high-frequency components compared to the 8 mm plate. Fundamental resonant frequencies of 3D-printed specimens were observed near 5100 Hz, with Q-factors ranging between 200 and 300. The study also found that a 10% increase in volumetric porosity led to a 7% downward shift in resonant frequencies. The developed PEMF device, operating at 50–230 V and delivering 1–5 pulses per minute, shows promise for rapid, non-destructive monitoring of structural joints. When combined with the coaxial correlation method, the system demonstrates enhanced sensitivity in detecting structural changes, utilising an electrodynamic actuator (10 Hz to 2000 Hz range). This integrated approach offers a 30% improvement in early-stage degradation detection compared to traditional methods.

## Full-text entities

- **Diseases:** shock (MESH:D012769), PEMF (MESH:D007922), joint damage (MESH:D007592), injury to (MESH:D014947)
- **Chemicals:** steel (MESH:D013232), copper (MESH:D003300), metal (MESH:D008670), aluminium (MESH:D000535), AlSi10Mg20 (-), stainless steel (MESH:D013193)