# Perfusion pressure as a determinant of respiratory function outcomes in unilateral biportal lumbar endoscopic procedures

**Authors:** Liang Zhang, Han Zheng, Yan Fu, Wenbo Li, Jianlong Lang, Yi Wang, Weibin Ren

PMC · DOI: 10.3389/fphar.2025.1593118 · Frontiers in Pharmacology · 2025-05-30

## TL;DR

This study shows that high perfusion pressure during a spinal procedure harms respiratory function in rats with dural tears but not in those without.

## Contribution

The study reveals how dural injury and perfusion pressure affect respiratory outcomes in unilateral biportal endoscopic procedures.

## Key findings

- High perfusion pressure impaired respiratory function in rats with dural rupture, reducing respiratory rate.
- Dural rupture led to more severe cauda equina nerve injury, as shown by pathological staining.
- Intact dura mater showed no significant respiratory impact from perfusion pressure changes.

## Abstract

UBE is used to treat most lumbar spine diseases, and it must rely on continuous infusion of saline to maintain a clear field of vision during the operation to ensure the smooth progress of the operation. Among many complications, the incidence of dural tear is the highest. Whether UBE can damage the dura and the effect of intraoperative perfusion pressure changes on respiratory function under different conditions are not clear.

In the present experiment, Wistar rats were implanted with diaphragmatic electrodes and divided into two groups (dura mater with rupture group and dura mater without rupture group). In the experiment, the perfusion pressure was continuously increased, and the water pressure was 6KPa, 10KPa and 14Kpa for 2 min, respectively. The changes of respiratory movement were observed and analyzed. The preoperative and postoperative MRI scan results were compared. Pathological staining was used to observe the spinal cord injury.

Finally, we found that high perfusion pressure impaired respiratory function in rats with dural rupture, mainly manifested as decreased respiratory rate, but had no significant effect on respiratory function in rats with intact dura mater. HE staining and toluidine blue staining showed more nishi in the cauda equina nerve of the rats in the dural rupture group. Immunofluorescence results showed that the degree of cauda equina nerve injury in the dural rupture group was more severe than that in the dural rupture group.

This study reveals the effects of perfusion pressure and dural injury on respiratory function in UBE, and avoiding dural sac rupture is an effective means to prevent and treat complications of UBE, which will provide a new perspective on UBE.

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC12162276/full.md

## Figures

6 figures with captions in the complete paper: https://tomesphere.com/paper/PMC12162276/full.md

## References

36 references — full list in the complete paper: https://tomesphere.com/paper/PMC12162276/full.md

---
Source: https://tomesphere.com/paper/PMC12162276