# Successful wire placement into eccentric calcified plaque using intravascular lithotripsy

**Authors:** Hiroshi Abe, Dai Ozaki, Takashi Tokano, Tohru Minamino

PMC · DOI: 10.1186/s43044-025-00656-w · The Egyptian Heart Journal · 2025-06-05

## TL;DR

Intravascular lithotripsy can safely help place wires into hard-to-treat, oddly shaped calcified artery plaques, improving PCI outcomes.

## Contribution

Demonstrates a novel technique using IVL to safely manage eccentric calcified coronary lesions.

## Key findings

- IVL enabled successful wire placement into an eccentric calcified plaque without complications.
- Low-pressure balloon expansion after IVL facilitated wire embedding and improved procedural safety.
- The approach may reduce the risk of coronary perforation in complex calcified lesions.

## Abstract

Eccentric calcified lesions pose significant challenges in percutaneous coronary intervention (PCI), as they are associated with an increased risk of coronary artery perforation and suboptimal stent expansion. Moreover, long-term outcomes with drug-eluting stents (DESs) in these lesions are less favorable. Intravascular lithotripsy (IVL) has emerged as a treatment option for calcified lesions. However, its efficacy in managing eccentric calcified lesions remains uncertain.

A 70-year-old male presented with angina starting a week ago. He was diagnosed with unstable angina, and a coronary computed tomography showed severe stenosis with calcified plaque in the right coronary artery. The coronary angiography confirmed severe, calcified, eccentric stenosis in the right coronary artery. Intravascular ultrasound (IVUS) showed an eccentric lesion with calcified plaque, and the diameter of the vessels before and after the lesion was about 6.2 mm on average. Due to the high risk of vessel perforation associated with rotablator and orbital atherectomy systems, intravascular lithotripsy was performed using a 3 mm balloon. The crack formation was observed on IVUS. IVUS image shows both the guidewire and IVUS catheter being partially embedded within the concavity of the calcified nodule, and a 4 mm balloon was used for low-pressure expansion to expand the calcified crackles. This allowed the wire to sink into the calcified plaque and enabled balloon expansion within the calcified region. The risk of coronary perforation was deemed reduced, and a 5 mm × 15 mm DES was successfully placed without complication.

The additional balloon dilation following IVL could allow the wire to enter the eccentric calcified plaque, enhancing procedural safety and effectiveness. Depending on how cracks form within the plaque, this approach may facilitate safer and more effective treatment of eccentric calcified lesions.

## Linked entities

- **Diseases:** unstable angina (MONDO:0006805)

## Full-text entities

- **Diseases:** coronary perforation (MESH:D003323), perforation (MESH:D057112), angina (MESH:D000787), calcified (MESH:D018333), stenosis (MESH:D003251), coronary artery perforation (MESH:D003324), unstable angina (MESH:D000789)

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC12141178/full.md

## Figures

1 figure with captions in the complete paper: https://tomesphere.com/paper/PMC12141178/full.md

---
Source: https://tomesphere.com/paper/PMC12141178