# Diagnostic value of multiple projection angle X-ray and CT 3D reconstruction for long-term unreduced posterior hip dislocation

**Authors:** Yansong Liu, Yongbo Ma, Zeming Liu, Xuzhuang Ding, Xiaowei Yao, Jiangqi Chang, Hao Li, Tao Wu

PMC · DOI: 10.3389/fsurg.2025.1512955 · Frontiers in Surgery · 2025-05-08

## TL;DR

This study evaluates how X-ray and CT 3D imaging can help diagnose a rare hip condition that is hard to detect with standard methods.

## Contribution

The study introduces the diagnostic value of specific X-ray angles and CT 3D reconstruction for a rare hip dislocation.

## Key findings

- The rhombus sign had the highest accuracy (89.33%) among X-ray signs for diagnosing the condition.
- CT 3D reconstruction showed high sensitivity across different planes, with axial CT at 70.83%.
- All tested imaging methods showed high intraobserver and interobserver consistency.

## Abstract

Long-term unreduced posterior hip dislocation is a rare and diagnostically challenging condition, with imaging findings often indistinguishable from those of other end-stage hip diseases. It remains a great challenge to determine whether certain imaging characteristics can improve the clinical diagnosis rate of long-term unreduced posterior hip dislocation.

We retrospectively reviewed 24 patients from 2010 to 2022. The diagnostic values of multiple projection angle X-ray and CT 3D reconstruction for long-term unreduced posterior hip dislocation were evaluated.

For aureole sign, 45.83% of patients (sensitivity = 45.83%, specificity = 81.52%, accuracy = 78.67%, Youden's index = 0.274, positive predictive value (PPV) = 17.74%, negative predictive value (NPV) = 94.54%, intraobserver consistency = 0.930, and interobserver consistency = 0.903) were diagnosed correctly. For obturator oblique radiograph of the pelvis, 58.33% of patients (sensitivity = 58.33%, specificity = 82.25%, accuracy = 80.33%, Youden's index = 0.406, PPV = 22.22%, NPV = 95.78%, intraobserver consistency = 0.923, and interobserver consistency = 0.900) were diagnosed correctly. For rhombus sign, 70.83% of patients (sensitivity = 70.83%, specificity = 90.94%, accuracy = 89.33%, Youden's index = 0.618, PPV = 40.48%, NPV = 97.29%, intraobserver consistency = 0.943, and interobserver consistency = 0.900) were diagnosed correctly. For CT 3D reconstruction, axial CT (sensitivity = 70.83%), coronal multiplanar reconstruction (sensitivity = 58.33%), and sagittal multiplanar reconstruction (sensitivity = 54.17%), all had high diagnostic values.

The signs, projection angle X-ray, and CT 3D reconstruction identified in this study are valuable in improving the diagnosis for long-term unreduced posterior hip dislocation.

## Full-text entities

- **Diseases:** hip diseases (MESH:D006617)
- **Species:** Homo sapiens (human, species) [taxon 9606]

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC12094939/full.md

## Figures

5 figures with captions in the complete paper: https://tomesphere.com/paper/PMC12094939/full.md

## References

35 references — full list in the complete paper: https://tomesphere.com/paper/PMC12094939/full.md

---
Source: https://tomesphere.com/paper/PMC12094939