# Effects of Two Different Rotary Files on Crack Formation in Dentin: A Scanning Electron Microscopy (SEM) Study

**Authors:** Ataul Hafeez Imran

PMC · DOI: 10.7759/cureus.82349 · Cureus · 2025-04-16

## TL;DR

This study compared two dental tools for root canal shaping and found that one caused fewer cracks in tooth structure, especially near the root tip.

## Contribution

The study provides empirical evidence comparing dentinal crack formation caused by ProTaper Next and Mtwo rotary files using SEM analysis.

## Key findings

- Both ProTaper Next and Mtwo rotary files caused dentinal cracks, but ProTaper Next resulted in fewer cracks.
- Cracks were more common in the coronal third, and Mtwo caused more cracks in the apical third compared to ProTaper Next.
- The difference in crack formation between the two file systems was statistically significant only in the apical third.

## Abstract

Introduction

Root canal preparation is a critical step in endodontic success, with rotary file systems playing a key role in shaping and cleaning the root canal system. This study aimed to compare the effects of ProTaper Next (Dentsply Maillefer, Ballaigues, Switzerland) and Mtwo nickel-titanium (Ni-Ti) (VDW, Munich, Germany) rotary file systems on dentinal crack formation using a scanning electron microscope (SEM) (Zeiss Evo 18; Carl Zeiss AG, Oberkochen, Germany).

Methods

Fifteen patients requiring bilateral extraction of single-rooted mandibular premolars for orthodontic reasons were selected. Extracted teeth were divided into two groups: group 1 (ProTaper Next) and group 2 (Mtwo). After standardized root canal preparation, the specimens were sectioned at 3, 6, and 9 mm from the apex and examined under SEM for crack formation.

Results

Both file systems induced dentinal cracks post-instrumentation. ProTaper Next files resulted in fewer cracks than Mtwo, but the difference was not statistically significant (p > 0.05). Cracks were more prevalent in the coronal third for both groups. The Mtwo system caused more cracks in the coronal and middle thirds, though this difference remained non-significant (p > 0.05). A statistically significant difference (p < 0.05) was observed in the apical third, where the Mtwo files induced more cracks than ProTaper Next.

Conclusion

Both ProTaper Next and Mtwo rotary files contribute to dentinal crack formation, with ProTaper Next causing fewer cracks, particularly in the apical third. These findings underscore the clinical importance of file selection in minimizing dentinal damage and reducing the risk of root fractures during endodontic treatment.

## Full-text entities

- **Diseases:** Cracks (MESH:D003387), root fractures (MESH:D011843)
- **Chemicals:** Mtwo (-), Ni-Ti (MESH:C013616)
- **Species:** Homo sapiens (human, species) [taxon 9606]

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC12082381/full.md

## Figures

2 figures with captions in the complete paper: https://tomesphere.com/paper/PMC12082381/full.md

## References

17 references — full list in the complete paper: https://tomesphere.com/paper/PMC12082381/full.md

---
Source: https://tomesphere.com/paper/PMC12082381