# Development of an LC-MS method for the determination of simvastatin and its hydroxy acid form in muscle tissue and method application

**Authors:** Ewa Paszkowska, Karolina Pietrowska, Steen Larsen, Emilia Fornal, Michał Ciborowski

PMC · DOI: 10.1371/journal.pone.0322808 · 2025-05-05

## TL;DR

A new method using liquid chromatography and mass spectrometry was developed to measure simvastatin and its metabolite in muscle tissue, helping understand statin-related muscle effects.

## Contribution

A novel LC-MS method for quantifying simvastatin and its hydroxy acid form in muscle tissue was developed and validated.

## Key findings

- The method showed good linearity, precision, and accuracy for simvastatin and its hydroxy acid form.
- Extraction efficiency and matrix effects were evaluated, with high recovery for the hydroxy acid form.
- The method was successfully applied to analyze muscle tissue from statin-treated patients.

## Abstract

Statins are the most commonly used drugs worldwide. Besides a significant decrease in cardiovascular diseases (CVDs) risk, the use of statins is also connected with a broad beneficial pleiotropic effect. At the same time, it is burdened with different side effects. The most common ones are muscle issues (from mild myalgia to rhabdomyolysis). The mechanisms of many of them are still unclear. Therefore, an analytical method for the determination of simvastatin (SIM) and its main metabolite (the hydroxy acid form – SIMA) in muscle tissue was developed.

Muscle samples were homogenized with ammonium acetate buffer using the bead mill homogenizer, and then statins were extracted with a mixture of methanol and ethanol. Prepared samples were analyzed with liquid chromatography (using a reverse-phase column with a gradient elution) combined with the mass spectrometer which was operated in a multiple reaction monitoring mode.

The assay was linear over a 0.1–5 ng/mL range for both statin forms. Inter- and intra-day precision and accuracy were characterized. The method was considered precise (with the following relative standard deviation values: 6.0–6.9% for SIM, and 8.1–12.9% for SIMA) and accurate (with the following mean accuracies: 91.4–100.1% for SIM, and 102.2–115.4% for SIMA). The extraction efficiency was evaluated by recovery determination (76% for SIM, and 99% for SIMA). Moreover, the matrix effect was calculated with the following results: 87% for SIM, and 139% for SIMA. The proposed method was applied for SIM and SIMA determination in skeletal muscle tissues obtained from statin-treated patients.

The obtained results proved that the method may be a useful tool for explaining muscle effects related to statin therapy.

## Linked entities

- **Chemicals:** simvastatin (PubChem CID 54454)
- **Diseases:** rhabdomyolysis (MONDO:0005290)

## Full-text entities

- **Diseases:** rhabdomyolysis (MESH:D012206), myalgia (MESH:D063806), CVDs (MESH:D002318)
- **Species:** Homo sapiens (human, species) [taxon 9606]

## Figures

12 figures with captions in the complete paper: https://tomesphere.com/paper/PMC12052154/full.md

---
Source: https://tomesphere.com/paper/PMC12052154